Skip to main content

Full text of "Home Power Magazine Issue 125 2008 06 07"

See other formats


xantrex 

Smart choice for power™ 

XANTREX™ GT SERVICE 
COMMITMENT 





XANTREX GT SERVICE COMMITMENT 



► 10 year parts and labor warranty 

► Dedicated toll free installer support line 1.866.492.6873. Open from 5:30 AM to 5 PM Pacific Time 

► Streamlined GT service process: 

► No Xantrex technical support troubleshooting required for inverter service exchange authorization 

► Inverter exchange replacements ship within 48 hours (2 business days) at no cost 

► Free overnight shipping of replacement inverters is available upon installer request 

► UPS call tag provided to installer for free shipping back to Xantrex 

► $250 installer reimbursement check issued within four weeks of receipt of returned inverter 

For more info please visit www.xantrex.com/GTSeries 



©2008 Xantrex and Smart choice for power are trademarks or registered trademarks of Xantrex International. 



2_homepower-gt-commit 




Alternative Energy Meets Affordability 



SunMaxx Solar Hot Water 
Systems provide the greatest 
value on the market - offering 
top-level performance at a 
price hundreds of dollars 
lower than the leading com- 
petitors. 

Today, heating costs for hot 
water and our homes can 
account for more than 40% of 
our home’s energy bills - with 
the price of oil and other fossil 
fuels rising every day, with no 
end in sight, it is important 
that we begin to look for alter- 
native ways to provide the 
necessities of life, such as hot 
water and a warm welcoming 
home. 



SunMaxx Solar Hot Water 
Systems can offset 60 - 80% 
of your home and water heat- 
ing needs - and many of our 
systems have a payback 
under 5 years. 

Free hot water and home 
heating can be yours in just 
days - call SunMaxx today 
and take the first step toward 
affordable energy indepen- 
dence. 

Since day one, SunMaxx has 
strived to make alternative 
energy affordable for hom- 
eowners across the country, 
and SunMaxx Solar Hot 
Water Systems make this 
mission a reality today! 

Pay Less for More with 
SunMaxx! 



June/July Bonus: 



SunMaxx 

Solar Hot Water Systems 



Evacuated Tube 
Solar Collectors 



S’ 



Flat Plate 
Solar Collectors 

Therm osyphon 
SHW Systems 

Pre-Packaged 
Domestic HW 

Solar Pool/Spa 
Heating Kits 



SunMaxx-20 

Evacuated Tube Solan Collectors 



Only $749.95 



(msrp: $850.00) 



FEATURED PRODUCTS 


MSRP 


SunMaxx-25 


$999.00 


SunMaxx-30 


$ 1,399.00 


SunMaxx-TS20 


$ 1,195.00 


SunMaxx-TS30 


$ 1,395.95 


40 Gallon Storage Tank 


$ 900.00 


80 Gallon Storage Tank 


$ 1,800.00 



* Prices Subject to Change 



Certified • Outperforms Leading Compe^jjtors J 



Solar Hot Water 
Chiller/ AC Kits 

Solar Hot Water 
Stroage Tanks 

Plate & Tube 
Heat Exchangers 

Circulator Pumps 
Controllers & More 



V. 




Shops 100’s of Solar Products 
Online @ 

www.siliconsolar.com 



Dealers Si Installers Wanted: inquire Tod 



Ul> Silicon Solar Inc 

Innovative Solar Solutions™ 









Products Services Learning Center 










PARTNER WITH A GLOBAL LEADER! 



There has never been a better time to invest in a solar energy system. Conergy makes it possible with 
an array of premium products supplied by the world’s leading manufacturers, custom solar finance 
solutions for homeowners and businesses and our national network of elite service providers. In more 
than 20 countries on 5 continents, we bring renewable energy solutions tailored to any application 
- from large power plants to remote, off-grid homes. Our local expertise, powered by our global 
strength makes us your ideal renewable energy partner. 

www.conergy.us | (888) 396-6611 




OUR WORLD IS FULL OF ENERGY 



PHOTO VO LTAICS I SOLAR THERMAL I SOLAR WATER PUMPS I SMALL WIND POWER I BALANCE OF SYSTEM 







the heart of your solar system 



Deep Cycle Power for Renewable 
Energy Systems - Solar , PV and Wind 



Off Grid & Grid Tied Systems 

Sun Xtender® Batteries are the Original “AGM” 
nt Glass Mat) Battery-Designed for the U.S. Military. 



— : "'Deep cycle unique high density plat* 

superior reliability, power & <. tended cycle iih. 

Valve regulated (VR), sealed non^spJHdBle design never 
needs watering, is maintenance 

Low impedance design with excellent cna^N 
acceptance - no current limit with controlled^ 

voltage chargihg. 

Shockproof high impact reinforced case restrains bulging. 

iff® M ^ i|P c ■ . . Jl/. mI . 1 i * jj, JR™ J p - * \ y ' jBI 

Copper alloy corrosion free connections for maximum conductivity. 



Sun Xtender® Providing Safe, Reliable Power Solutions Worldwide Since 1987 



Power when you need it 

www.sunxtender.com 



fiPi 



Crafted for quality in the U.S.A 



Sun Xtender® Batteries are Environmentally Friendly 
- 1 00% Recyclable 



AS 9100 REV. B:2004 and ISO 9001:2000 

k'/ . J, 'V^ i.(jF vj fl 5 M 

phone 626-813-1234 fax 626-813-1235 www.sunxtender:com 

<► * .# t t J - r 1 'fyjV j : \ijfi J?' . 



Concorde Battery Corporation 




Join the Hottest Team 
in the Solar Business! 





solar experience support 
you at every g • | 

step. 



Get everything you 
need to deliver NEC-compliant 
solar solutions - profitably 
and on schedule! 



What makes AEE Solar the fastest-growing 
wholesale distributor in the renewable 
energy business? 



support 



The most highly 
respected technical 
support and customer 
service in the industry. 
Our three decades of 



training 

Ongoing, comprehensive 
dealer training - from 
beginner to advanced, 
online or hands-on, 
regional and local. We help 
you master the skills you 
need to succeed. 



products 

Proven, tested 
products at highly 
competitive prices. 

If AEE Solar carries it, 
you know you can 
count on it. 



catalog 

Our renowned annual 
Renewable Energy Design 
Guide & Catalog. Use the 

industry’s most sought-after 
resource as your own 
powerful sales tool! 



inventory 

The widest inventory 
selection in the 
business combined 
with just-in-time 
delivery. We stock it all 
so you don’t have to! 



financing 

Financing packages for 
your customers. Close 
more sales with convenient, 
affordable renewable energy 
financing. 



Whether you are an industry veteran or a solar rookie, put AEE Solar 
on your team for solar success! Call or apply online today! 

www.aeesolar.com 




The Only Wholesale Distributor You’ll Ever Need 



800 - 777-6609 707-923-2277 1 1 55 Redway Drive 

8:30 to 5:00 Pacific Time 707-923-3009 fax PO Box 339 



Monday-Friday 



sales@aeesolar.com Redway, CA 95560 








< 




June & July 2008 




: 30 sustainable sailing 

Derek Young 

After using a noisy diesel generator for onboard electricity, Mike and 
Joanne Young installed wind and PV systems on their 37-foot sloop. 

,,.'"38 catching rain 

Heather Kinkade 

Keep your gardens lush and provide drinking water from rainwater 
harvested on site. Expert advice on catchment system components. 

* 46 carbon free 

Mel Tyree 

Mel and Charleen Tyree took the zero-carbon challenge, building a 
home that's powered entirely with clean, renewable energy. 



56 hydro penstock 

Jerry Ostermeier 

Maximize your microhydro system performance with sound pipeline 
practices. 



home power 125 /june & july 2008 



Clockwise from lower left: Courtesy lari Woofenden; Mel Tyree; www.rainharvesting.com; Roger Webb; www.solarworld-usa.com; Suzanne Olsen; www.lorentzpumps.com 




On the Cover 



Mike and Joanne Young take renewable energy to 
the seas, using a small wind turbine and a PV system 
to meet most of their onboard electricity needs. 

Photo by Roger Webb 







66 string theory 

Ryan Mayfield 

For best PV system performance, size array strings to meet the 
requirements of your inverter and climate. 



• • *74 solar pumping 

Erik Lensch 

Solar-electric pumping systems offer an affordable, sustainable 
solution for your water needs. 



From Us to You 



Home Power crew 

Getting a grip on the grid 



12 


Ask the Experts 
Industry professionals 

Renewable energy Q & A 


22 


Mailbox 

Home Power readers 

Feedback forum 


106 


Code Corner 
John Wiles 

To fuse or not to fuse 


112 


Independent 
Power Providers 

Don Loweburg 

Organizing the pros 


116 


Power Politics 
Michael Welch 

Getting FIT 


120 


Home & Heart 

Kathleen 

Jarschke-Schultze 

Home field advantage 


126 


RE Happenings 


128 


Marketplace 


130 


Installers Directory 



82 net zero 

John Patterson 

Harvesting sunlight to meet their lighting, electricity, and water heating 
needs was a smart move for this Portland, Oregon-based company. 



135 Advertisers Index 

136 RE People 

Meg Thomas 



92 certified solar 

Chuck Marken with Doug Puffer 

Pick the perfect solar hot water system for your climate and site. 



Home Power (ISSN 1050-2416) is published bimonthly 
from offices in Phoenix, OR 97535. Periodicals postage 
paid at Ashland, OR, and at additional mailing 
offices. POSTMASTER: Send address corrections to 
Home Power, PO Box 520, Ashland, OR 97520. 



www. homepower . com 




The OutBack Power Systems 



FLEXnet™ DC is the ultimate in 
DC System monitoring devices. 
Our integrated networked 
communications make valuable, 
usable data available from your 
system, providing you with the 
answers you need concerning 
your system's health, 
performance and efficiency. 



Power Systems 

Corporate Headquarters European Sales Office 
19009 62nd Avenue NE Barcelona, ESPANA 

Arlington, WA USA +34.93.654.9568 

+1.360-435-6030 



from us to you 

GETTING A GRIP ON THE GRID 



In the early days of the magazine. Home Power's goal was to network a fledgling 
off-grid solar movement. Our efforts created an ongoing information exchange that 
helped build the foundation of today's solar industry. About a decade ago, our 
focus shifted to bringing these proven technologies out of the backwoods and into 
backyards by sharing information on the latest in grid-tied solar-electric systems. 
After all, the vast majority of Americans live on grid, and in this wired realm, the 
potential for solar energy borders on limitlessness. 

But where bringing the benefits of RE to off-gridders has been straightforward, 
interfacing solar technologies with the utility grid has been anything but simple. 
Some issues have been technical, but many have been related to policy, legislation, 
incentives, administration, and straight-out education about the impacts of 
PV technology on the grid-tied world. Just like in the early days, increasing 
communication between experienced and inexperienced users was key. 

Along these lines, a recent report (www.solarelectricpower.org) published by 
the Solar Electric Power Association and the Interstate Renewable Energy Council 
caught my attention — and my imagination. The report was based on a survey of 
utility practices related to residential-scale grid-tied PV. "Several utilities reported 
thousands of PV systems. But the majority of utilities have not yet reached critical 
mass," said Mike Taylor, SEP A director of research. One of the conclusions drawn 
in the report is that solar-experienced utilities could assist utilities with little or no 
experience with small-scale distributed generation. 

The concept of experienced utilities helping inexperienced utilities smooth the 
way for future PV installations is a fascinating indication of the momentum that's been 
created. And looking at what's coming down the pike, it's a necessary development. 
In the United States, installed PV capacity grew by 60% — 101 megawatts — between 
2005 and 2006. As impressive as these figures are, a five-fold increase in domestic 
PV capacity and the number of installations is projected over the next three to four 
years. 

Advances in equipment design and system installation are guaranteed in today's 
competitive RE market, but information exchange, as pivotal as it is, isn't. If you have 
RE experience, share it. In many cases, it's the most powerful thing you can do to 
change the way we generate energy in the United States and beyond. 

— Joe Schwartz for the Home Power crew 



</> 

P 

cc 

£ 

(0 

U) 

0 




Year 

Cumulative Current & Forecasted 
U.S. PV Installations & Installed Capacity 



300,000 


< n 

C 


250,000 


O 

JS 


200,000 


+-• 

</> 


150,000 


c 

M— 

o 


100,000 


5 _ 

0 

Jd 


50,000 

0 


E 

3 

z 



Think About It... 

"Information's pretty thin stuff unless mixed with experience." 

— Clarence Day 



www.outbackpower.com 



home power 125 /june & july 2008 



Source: Larry Sherwood, IREC (2000-2006 data); Travis Bradford, Prometheus Institute (MW projections); Mike Taylor, SEPA (number of installation projections) 





*SP 





rriax 







l 



t 



£ 



..■..'V- • . . 







l otf’,. 

I 



Ifll 


i .4 «j 


AVSA "1 


C*J|. 




tD-G-Ps 1 




A.™ k'J 


ie.2-.yp 1 




Mi 


Ml I l =i-.- ii | 



rtutsBnck 

Power System* 



Built-in 1 23 Days of 
Data Logging 

fully OmBack Network 
Integrated and 
Programmable 



Full flO Amp Output Capacity 
in Ambient Temperatures 
up to 104*F (40“Q 

Easy to Replace, 
23.9 Tear M-TSF 
Cooling fan 

Programmable 12 Vole 
Auxiliary Output Signal 

Advanced Continuous 
Maximum Power Point 
Tracking Algorithm 



The latest innovation in Maximum Power Point Tracking (MPPT) charge controllers. 



www.flexmax80.com 



Power Systems 








Publishers 


Richard & Karen Perez 


Executive Editor & CEO 


Joe Schwartz 


Managing Editor 


Claire Anderson 


Art Director 


Ben Root 


Senior Editors 


Michael Welch, Ian Woofenden 


Technical Editors 


Justine Sanchez, 

Roy Butler, Erika Weliczko 


Associate Editor 


Kelly Davidson 


Graphic Artist 


Dave Emrich 


Solar Thermal Editor 


Chuck Marken 


Building Technology Editor 


Rachel Connor 


Transportation Editors 


Mike Brown, Shari Prange 


Columnists 


Kathleen Jarschke-Schultze, Don Loweburg 
Michael Welch, John Wiles 


Advertising Manager 


Connie Said 


Advertising Director 


Kim Bowker 


Chief Information Officer 


Rick Germany 


Operations Director 


Scott Russell 


Data Manager 


Doug Puffer 


Customer Service & Fulfillment 


Jacie Gray, Shannon Ryan 



She’ll graduate 
high school. 



Copyright ©2008 Home Power Inc. All rights reserved. Contents may not be reprinted or otherwise reproduced without 
written permission. While Home Power magazine strives to publish only safe and accurate content, we assume no 
responsibility or liability for the use of this information. 

Interior paper is made from 85%-100% recycled material, including 20%-30% postconsumer waste. 



Your Fronius solar 



Contact Us... 



inverter will still be 
covered by our new 

15-year warranty*. 




POWERING YOUR FUTURE 



www.fronius-usa.com 



* Call your Fronius representative 
for pricing and details. 



Subscriptions 

To subscribe, renew, change, or inquire about 
a subscription: 

800-707-6585 or 541-512-0201 

subscription@homepower.com 

www.homepower.com/subscribe 

Back Issues 

Many of our back issues are available in print 
and/or online in Adobe PDF. Our first 120 
issues are also compiled on DVD-ROM. 

More information at: 

www.homepower.com 

Order online or by phone: 

800-707-6585 or 541-512-0201 

Submissions 

For inquiries and information related to 
editorial submissions, write to us at: 

submissions@homepower.com 

www.homepower.com/writing 

Marketing 

Promotional opportunities and offers: 

marketing@homepower.com 



Ask the Experts 

To have your technical questions considered 
for publication, send them to: 

asktheexperts@homepower.com 

Web Site 

www.homepower.com 

Send your comments and suggestions 
regarding the site to: 

web@homepower.com 

Advertising 

For inquiries and information related to 
advertising in Home Power or on 
www.homepower.com, contact: 

connie.said@homepower.com 

541-512-0201 

kim.bowker@homepower.com 

541-858-1791 

www.homepower.com/advertising 

Letters to the Editor 

E-mail your comments and suggestions 
to us at: 

mailbox@homepower.com 

or write to the address below. 



Home Power magazine • PO Box 520 • Ashland, Oregon 97520 • USA 



Expect 

higher 

standards 



J 




15-year warranty now available from Fronius 



Fronius, an innovative solar inverter company, is raising the bar with another first. As part of our 
Fronius Gold Quality Guarantee program, we are offering a 15-year warranty* on all of our solar inverters. 
Fronius’ priority is to manufacture the highest quality inverters available and now supports this with an 
industry-leading 15-year warranty. 

Enjoy peace of mind with your solar investment, knowing that you are covered for a full 15 years. 

Take a look at what 60 years of experience can do for you. 

Fronius USA LLC, 10421 Citation Drive, Ste 1100, Brighton, Ml 48116 

Tel: 810-220-4414 Email: pv-us@fronius.com Web: www.fronius-usa.com 




POWERING YOUR FUTURE 



* Call your Fronius representative for pricing and details. 






Alaska Solar 

I live on-grid in Anchorage, Alaska, and I'd like to install solar-electric modules on 
my roof. However, most of the information I can gather discourages their use in this 
climate. 

I'm willing to use conventionally generated electricity in the winter, but in the 
summer. I'm sure there must be a way for me to rely solely on solar-generated 
electricity. Anchorage also doesn't get as much rainfall as the southeastern region 
of the state, and in summer, we receive 18 to 19 hours of daylight. Can you make 
any suggestions for the type of system that would be economically feasible for me 
to install? 

Ann Pence • Anchorage, Alaska 



Peak Sun-Hours 
Compared 

Avg. Daily 
Peak Sun-Hours* 



Location 


Jan. 


Jul. 


Annual 


Anchorage, AK 


1.0 


4.4 


3.0 


Seattle, WA 


1.6 


5.7 


3.7 


Los Angeles, CA 


4.4 


6.6 


5.6 



*Fixed array, oriented to true south, tilt = latitude 



It's a fact that Alaska in general doesn't get as much solar radiation 
as most locations in the southern 48 states. Still, if you installed a 
700-watt array at a really good site, you could expect to generate 
at least 550 KWH per year (per the solar performance calculator at 
http://rredc.nrel.gov/solar/codes_algs/PVWATTS/). A ballpark 
cost would be $6,000 to $8,000 installed, and would qualify you for 
a $2,000 federal tax credit if your system was installed this year. 

Unfortunately, the utilities serving Anchorage don't currently 
allow net metering or offer any incentives. This means they would 
pay at an "avoided cost" rate for electricity your system sends to the 
grid in excess of your usage between meter readings. Avoided cost is 
typically 4 to 8 cents per KWH, but may be less. 

In Fairbanks, Golden Valley Electric Association started an 
incentive program called SNAP (Sustainable Natural Alternative 
Power) about two years ago. Based on the original SNAP program 



started in Chelan County, Washington, this program offers up to 
$1.50 per KWH to local renewable electricity producers who sell 
electricity back to the grid. 

Recently I heard that Chugach Electric in Anchorage and Homer 
Electric in Homer will be starting their own SNAP programs this 
year. You should contact your utility to see if any incentives are 
available now or will be in the future. 

If it turns out that PV just isn't economical enough at this time, 
there are plenty of cost-effective energy-efficiency improvements that 
you could make to your home. Look into the Anchorage Department 
of Neighborhoods' Weatherization Program and the Cooperative 
Extension Service in Fairbanks. Both are awesome resources for 
information on energy-efficient living in Alaska. 

Greg Egan, Remote Power Inc. • 
Fairbanks, Alaska 



home power 125 /june & july 2008 



Courtesy remotepowerinc.com 







They suffered from irreconcilable similarities. 



You're concerned about the price of electricity. She's worried about global warming. You want less reliance on imported 
energy. He wants more energy freedom. Well, at least you can agree on a residential wind generator. Designed specifically 
for grid-connected homes, the Skystream 3.7 @ allows you to take control of your energy needs by converting the free 
energy in the wind into electricity. Skystream can lower your electric bill by as much as 80%, protect you against volatile 
electricity prices, reduce your dependence on foreign oil, and produce clean green energy that doesn't cause global warming. 
Most importantly, it provides greater independence and stability for you and your family. This, we can all agree on. 












SKYSTREAM 37 

Visit skystreamenergy.com or call 1-866-807-9463 for a dealer near you. 






Roof Replacement 

I'd like to go into the business of installing rooftop solar energy systems on newly 
constructed buildings, but I'm concerned about the problem of roof replacement twenty 
years down the road. I can see a major disruption to PV modules and solar thermal 
collectors during reroofing. Are there installation techniques that address this problem? 

Fred Mocking • Skokie, Illinois 




Since removal and reinstallation of roof-mounted solar equipment 
can be quite expensive, usually requiring more labor hours than 
the system originally took to install, the frequency of possible 
roof replacement definitely needs to be considered. With new 
construction, the first thing is to start with a durable roofing material 
that has the longest life span you can afford. If you can install a roof 
that will last 30 to 40 years (or more), its longevity will be right in line 
with that of your solar energy system. 

When it comes to purchasing a mounting system, I prefer to 
use round-style mounting posts, which mount on the roof decking, 
instead of feet made of angle stock (L-shaped mounting feet), which 
mount on top of the roofing. Round posts are flashed and roofed 
around just like a normal pipe vent. When it's time to remove and 
then reinstall the system for a new roof, you don't have to remove the 
mounting feet themselves, just the roofing material around them. If 
you're replacing the roof and have used angle-stock style mounting 
feet, you'll have to remove all the feet and will have to install your PV 



array or solar hot water collectors from scratch after the new roof is 
in place. Compared to angle-stock style mounting feet, round, flashed 
mounting feet will likely be more watertight in the long run. 

Roofs in general are not intended to be walked on. Installing solar 
energy systems can result in substantial foot traffic on roofs, and even 
new roofs can be damaged during this process, taking valuable years 
off the life span of the roofing material. This is an especially important 
consideration with composition (asphalt) shingle roofs. On hot days, 
the asphalt will soften, making the shingles more vulnerable to 
damage. If you must work on the roof during hot weather, wear flat, 
soft-soled shoes instead of raised-heel work boots to avoid damage. 

In all you do, remember to make safety your first priority — 
working on roofs puts you at risk for serious fall hazards. Don't forget 
to install permanent safety anchors when the new roof is going on, 
and use harnesses and fall protection gear while installing systems. 
Good luck, and work safe. 

Kristopher Sutton, Sutton Solar • Paonia, Colorado 



14 



home power 125 /june & july 2008 





water filled brushless DC motor 
maintenance-free 

no electronics in the motor 

1 2-200V DC, 1 1 0-240V AC solutions 

modular concept: pump end, motor, 
controller are seperate parts 

all 316 stainless steel, 
not thinner than 0.16" (4mm) 

2,000ft (600m) lift ability 

pump speed adjustable 

remote tank shut off with integrated 
timer and pressure switch 

largest variety in solar industry: 
helical rotor, centrifugal, vane-type, 
submersible, surface or floating pump 



LO-RENJZ 



LORENTZ Germany 

www.lorentz.de 

Dealers: CAP Solar Canada, www.capsolar.com, Tel. (866) 556 8779 (toll free), Fax (403) 556 7799 
GENPRO USA, www.genpro.us, Tel. (866) 593 0777 (toll free), Fax (605) 341 9918 
KELLN Solar Canada, www.kellnsolar.com, Tel. (888) 731 8882 (toll free) , Fax (306) 731 2774 
Solar Power & Pump Co. USA, www.togosolar.com, Tel. (866) 246 7652 (toll free). Fax (580) 225 1 120 



LORENTZ 

SINCE 1993 

SOLAR WATER PUMPS 







Ask the EXPERTS! 



Off Grid or Not? 

I'm shopping for rural property, and have 
looked at some parcels that are off the 
grid — some a short distance from utility 
lines and some a very long way. I don't 
know a lot about solar- and wind-electric 
systems, and hope you can give me some 
guidelines to help compare the cost of 
installing and owning a system with 
the cost of utility line extension. When 
is staying off grid — or connecting to the 
utility — worth it? 

Pete Little • Los Angeles, California 




One of the main financial advantages to off-grid living is the lower 
cost of land. But if you want electricity at your remote property, 
be prepared to pay. Whether your money goes to a stand-alone RE 
system or to the utility to bring in a line will be up to you and what 
your end goals are. In some areas, the expense of line extension will 
be prohibitive, making your decision to stay off grid easier. But if 
connecting to the utility grid costs $5,000 or $10,000, your decision 
may be a little more difficult. 

Your first step should be to examine your motivations and goals. 
While many people dream of being off grid, they often are not aware 
of the responsibilities and ongoing costs. In most places, utility 
electricity is inexpensive compared to making your own electricity 
off grid, and when there's any maintenance or troubleshooting, you 
just call the utility. Off-grid system owners must be prepared to take 
on the utility's job, or pay someone else to do it. 

So just how expensive is a residential off-grid electrical system? 
This depends on several factors, including incentives, the renewable 
resources available, and local installer pricing. But the biggest factor 
is the one only you can answer — how much electrical energy do you 
need? Here are some ballpark figures, and the resources to do your 
own analysis. 

According to a Lawrence Berkeley National Laboratory study, 
the average house in your utility's service area used 5,900 KWH per 
year in 1999. Consider the cost of powering that average home with 
a PV system. 

Using the PV output calculator (http://rredc.nrel.gov/solar/ 
codes_algs/PVWATTS/), with default settings for Los Angeles, a 
system of 5 KW peak can meet the annual need, but you'll have 47% 
more energy available in August than in December. Most off-gridders 



do not try to size their system to provide all of their electricity in 
the winter; instead they rely on a backup generator to make up for 
reduced solar electricity generation. This hypothetical homeowner 
may buy a smaller system that meets demand for a portion of the 
year, and rely more on the engine generator during the winter. 

As a very rough approximation, I use a total installed system cost 
of $12,000 per KW peak for an off-grid solar system. So powering the 
average home in southern California would require an investment of 
about $60,000! Some incentives may apply, but few are applicable to 
off-grid systems (see www.dsireusa.org). 

Fortunately, most off-grid homeowners manage to live well 
using much less electricity than the average homeowner. This is 
accomplished with a mix of energy shifting (using gas or propane 
instead of electricity), efficiency (Energy Star appliances and compact 
fluorescent lighting), and conservation (turning off lights, no central 
air conditioning, etc.). As a result, many off-grid households manage 
with a PV system that produces about 1,500 KWH per year. In 
California, this would correspond to a system of about 1 KW peak, 
or $12,000. 

If your site is blessed with a good average wind speed or a 
flowing creek, a hybrid system is likely to cost less than an all-PV 
system. But the output of a wind or hydro system is very site specific, 
so I can't be more exact. 

The lack of utility access can save you money when buying land, 
perhaps enough to pay for your off-grid electric system, but you're 
wise to "run the numbers" before you buy. 

John Richter, 

Institute for Sustainable Energy Education • 
Bingham Farms, Michigan 



16 



home power 125 /june & july 2008 




The right 
fit matters 




There is a Magnum Inverter/Charger to fit your needs 




MM-AE Series 
Inverter/Charger 



Modified sine wave, 

600- 1500 watts, 12-24VDC 

Available models: MM612AE, 
MM1212AE, MM1524AE 





MS Series Inverter/Charger 

Sine wave, 

2000 - 4000 watts, 12 - 24 VDC 

Available models: 

MS2000, MS2000-20B, MS2012, 
MS2012-20B, MS2812, MS4024 



MS-AE 120/240V Series 
Inverter/Charger 

Sine wave, 

4000 - 4400 watts, 24 - 48 VDC 

Available models: 

MS4024AE, MS4448AE 




RD Series Inverter/Charger 

Modified sine wave, 

1800 - 3900 watts, 12 - 24 VDC 

Available models: RD2212, 
RD1824, RD2824, RD3924 



Available Accessories: 

Automatic Generator Start Module (AGS), Battery Monitor Kit, 

Conduit Box, Fuse Blocks, Ignition Switch Lockout, LCD Remote Displays, 
Remote Switch Adapter, Series Stacking Cable Kit 




Call and ask for our full catalog for 
complete product information. 

Phone: 425-353-8833 

Web: www.magnumenergy.com 




awa^m w« mrawa 

ENERGY 



The Powerful Difference 







Solar Radiator 

I want to use a 3- by 8-foot solar water-heating collector connected to a radiator to 
help heat an 8- by 10-foot room in my basement. If the water can reach temperatures 
between 140°F and 150°F, it should be hot enough to serve this function. Then, it's just a 
question of which type of radiator to use. I was thinking of using a standard baseboard 
heater or maybe an old cast-iron radiator. Then I thought about the advantages of using 
a thermal heat-storage "block" made of bricks. Hot water from the collector could be 
circulated through the block, which would absorb and slowly reradiate the heat. What 
do you think? 

Paul Melanson • Nova Scotia, Canada 

Your best bet for passive radiation is a baseboard element. Cast-iron radiators were designed 
for steam heat — they'll work with hot water, but not as effectively as a baseboard element. It is 
much more effective to use water as a storage medium than masonry block, because its specific 
heat (heat content) is about five times that of brick's specific heat. 

If you don't mind the cosmetic appearance, a solar collector heating an uninsulated steel 
tank will make up a low-cost system. Make the system a drainback system and you'll just have 
four components — tank, pump, control, and collector. From a quick glance at the sunlight 
available in Nova Scotia, a 3- by 8-foot collector probably won't heat more than a 30-gallon tank 
in the winter. The beauty of this system is its simplicity and the fact that the tank keeps adding 
positive heat to the room down to 60°F or so. 

Chuck Marken, AAA Solar • Albuquerque, New Mexico 




Storage Tank: 

30 gal., uninsulated 



RE Family 

While my wife and I are interested in using energy more efficiently, 
and saving money doing it. I'm the one more interested in things 
like solar electricity and solar hot water. While saving money 
is an incentive. I'd like some advice from Home Power or from 
other readers on how they discussed moving toward a more 
renewable lifestyle with a spouse or significant other who isn't 
quite as motivated. 

R. Tomaro • via e-mail 




When my husband Lance and I first got together, we were already 
pretty well in agreement that we needed to take care of our own little 
corner of Earth. Over the years, we've had long conversations about 
our consumer society, and why we feel we need to do something 
personally. Well, we are still discussing that one 17 years later, and 
the list of what we plan to do comes out of our ongoing conversation! 
So we're in agreement about the direction we want to go, and we 
respect each other's reasons. 

You two seem to be in agreement that it's important to try to 
live more responsibly. That's significant, and it's a great starting 
point for conversations. Each of you notices different symptoms of 
the unsustainable direction our society is tending, and you can share 
your observations as you gradually make your own decisions about 
what steps to take in your lives. 

Now the only question is, how do you choose to go about it? 
People will order their lists differently, but assuming that your 
spouse agrees with you about the big picture, maybe it's just a 
question of what measures to start with. How about starting with 
some smaller things that can have a big impact, like weatherization 
or energy-efficiency upgrades? Maybe a more resource- and people- 
friendly yard? For ideas, check out the local solar tour of homes in 
your area (www.nationalsolartour.org). If you have kids, get them 
involved in the decision-making process. When your spouse and 
children see how pleasant this money-and-resource saving can be, 
they will eventually want to take the bigger steps. 

Jennifer Barker, EO Renew • John Day, Oregon 

Debra Galandzy and Doug Horn implemented energy-efficiency 
measures and installed a solar-electric system at their 
Vancouver, British Columbia, home. 



home power 125 /june & july 2008 







SunWize 

Grid-Tie 

Systems 




SunWize Grid-Tie Systems 
offer the high-efficiency 
Sanyo HIT 190/200W 
solar panel. 



The Ideal Solar Solution for Residential 
and Light Commercial Applications 

SunWize pre-packaged grid-tie systems and grid-tie 
systems with battery backup contain everything you 
need for a complete installation. SunWize Grid-Tie System 
are easily installed on any type of composition or tile 
roof. Multiple systems can be installed for higher power 
output and some systems may also be expanded in the 
future as budget or electrical requirements grow. 

Many SunWize Grid-Tie Systems are certified by the 
Florida Solar Energy Center (FSEC) for high quality, reliable 
and safe operation compliant to the NEC. The FSEC 
certificate is useful for permitting and field inspections 
of installed systems. Contact us and find out how we can 
help your business. Be successful, choose SunWize! 

OFFICES THROUGHOUTTHE US AND CANADA 
800.81 7.6527 • info@sunwize.com • www.sunwize.com 



SunWize 



Reliable People Reliable Products ::: Reliable Power! 








ler Advantage 



✓ Pre-Engineered Packaged Systems 

✓ Superior Technical Support 

✓ Free Jobsite Delivery* 

✓ Product Shipment Nationwide 

✓ Training Workshops 

✓ Rebate Filing Assistance 

✓ Lead Referral Program 

✓ Marketing & Advertising Support 



■ ^ „ : p r A <■ ■ 

A j ■■ -V 



n 

4 <■-» <- 

-t . V ■ 



-a 

, tf ♦ r; : 

• J ?- j- -- ■■>!**" 



Experience. Quality. Integrity. 






‘ Within 1 00 mile radius of our branches 



Solar PV / Solar Water Heating / Solar Pool / Radiant Floor Heating 

(Homeowner and Business Owner Inquiries Welcome) 



Petaluma, CA 
800 - 822-4041 



Sacramento, CA 
800 - 321-0101 



Corona, CA 
800 - 680-7922 



Mailbox 



A Better Hydro Intake 

I was disappointed not to see a simple, in-stream intake 
included in Jerry Ostermeier's otherwise excellent article 
in HP124. Using the Hydro-Shear Coanda effect screen from 
Hydroscreen, I've installed simple, in-stream intakes multiple 
times, by choosing a suitable spot in the stream, and either 
building or inserting a screen box. Though these screens 
weren't originally designed to be submerged, my experience 
is that they work very well in this configuration if a vent is 
included lower on the penstock to release trapped air. 

I've used 1 square foot of the screen to collect more than 
100 gallons per minute (gpm), which covers many home-scale 
systems' needs. (The manufacturer claims it can collect 225 gpm 
per square foot.) By avoiding building a dam, we not only reduce 
the embodied energy in a hydro installation and minimize the 
impact on the streambed, we also keep the impact on the stream 
flow to a minimum, and don't impede fish. One of my intakes is 
so well hidden that the house sitter couldn't find it, even when he 
knew it was there. 

I installed one that I only visit once a year for maintenance 
checkups. I've found that the screens are very much self-cleaning. 
Sometimes sand or pine needles will partially slow the intake. The 
worst blockage I've seen was by algae growth in a sunny location. 
An occasional scrub with a brush solves that problem. 

Screens well anchored to large rocks need very little concrete 
to make a robust intake that is immune to flash floods. The water 
doesn't have anything to oppose it, and just flows over the top. 

Chris Soler, Soler Hydro-Electric • Bow, Washington 



"I've installed simple, in-stream 
intakes multiple times, by 
choosing a suitable spot in the 
stream, and either building or 
inserting a screen box." 




Skip the Politics 

In your editorial, "Waiting for the Sun" in HP123 , I noticed an 
anti-Bush, anti-Republican tone. I must be blunt and let you 
know I don't like that at all. 

I don't care if you vote Democrat or Republican; I just don't like 
the magazine to be infused with any politics. I pay to subscribe 
for the sole purpose of improving our world, not to listen to your 
prejudices about what one party did to another and what one party 
has done for RE versus another. I don't need or want your help 
in looking at these issues. If I want editorials on which party did 



"better" than the other, countless magazines can give me that. 

I don't want to read another boring, biased editorial. Please 
just stick to RE untouched by bias (yours or anyone else's), and 
let us read a magazine that helps get on with the job of RE. 
Home Power is about solutions. Your editorial was not about 
solutions. RE is about unity, not division. Your editorial was 
about division, not unity. Both parties share the blame for the 
mess we are in. Don't try to make it someone's fault when we all 
share the blame. It serves no purpose. 

Robert Montgomery • via e-mail 



"Both parties share the blame for the mess we are in. Don't 
try to make it someone's fault when we all share the blame." 



home power 125 /june & july 2008 





Trusted 

10,654 miles from our test center 




Customers rely on the long-term performance of our solar 
inverters. That's why over 750,000 of them are in service 
around the world. Our innovative engineers have developed 
a complete range of inverters, all designed, manufactured, 
and tested in Germany. 

New product line now available 
Complete range of 2007-UL-compliant inverters from 700 
to 7000 watts, featuring integrated disconnect switches with 
easier conduit knockouts, andtheSunny Tower, handling 
36 to 42 kW, for simplified commercial installations. 
10-year warranty now standard on 2007 inverter line. 



Call us: (888)476-2872 
www.sma-america.com 



Rock Solid Solar 



r 



■ A 




Mailbox 






• committed to providing the 
highest quality solar energy 
solutions 

• empowering individuals, 
communities, & businesses 

• contributing to a sustainable 
future and clean energy 
economy 

Independence 
You Can Afford 




affordable solar 



Hybrid Footprint 

In regards to the article "Plug-in Hybrids" in HP121, the author points out that it is more 
economical to drive a vehicle with batteries recharged with utility electricity than to 
drive a gas-consuming vehicle. But being more economical does not mean you have a 
smaller carbon footprint or that you're burning less primary fuel (usually combustible 
fossil fuel). Because of inefficiencies in heat engines and distribution losses, typically 
only about one-third of the energy in a combustible fuel is turned into electrical energy. 

The article states that 1 gallon of gasoline is equivalent to 34 KWH of electricity. In 
practice, 1 gallon of combusted gasoline will produce 11 KWH of electricity, not 34 KWH. 
One of the comparisons the article makes is between an electric car and a hybrid Prius. 
In the author's comparison, an electric car can travel 110 miles on 34 KWH, assuming 34 
KWH is the amount of heat energy in a gallon of gasoline. But typically only one-third 
of this energy can be converted to electricity. The electric vehicle's mileage is then 110 
divided by 3, or 36.6 miles per gallon. The author points out that the Prius at 50 miles per 
gallon costs twice as much to operate per mile. 

With the author's assumption that most of the electricity generated in the United 
States is produced using fossil fuels, the Prius will consume 35% less primary energy 
than the electric car. However, because of the price structure, the electric car will cost 
less to operate. 

The amount of carbon put into the air while generating electricity will depend on 
the type of fossil fuel consumed at the power plant. Per unit of energy, coal produces 
66% more carbon dioxide (C0 2 ) than gasoline, and natural gas produces 20% less. The 
article points out that half of our electricity comes from coal. If more of our electricity is 
produced by renewables, the primary energy consumption and carbon footprint will be 
reduced for the electric car. 

One reason for an electric car's economic advantage is that there are fewer taxes on 
electricity than gasoline. As a consequence, taxes will go up someplace else to pay for 
our roads. In the article on my house in HP112, this point is discussed further in regards 
to gas and electricity consumption for a home. For a home generating more electricity 
than it consumes, the article looks at the relative merits of feeding this electricity into 
the grid or using the excess electricity to reduce natural gas consumption. In California, 
if you generate more electricity than you consume on a yearly basis, you are not paid 
for the excess electricity you feed into the grid. In my home, I decided to feed my excess 
electricity into the grid. This further reduced my carbon footprint but resulted in a larger 
utility bill. My point is that the price structure does not always encourage the most 
efficient way to consume energy. 

Larry Schlussler, Sun Frost • Areata, California 



The efficiencies of creating electricity depends 
on the generator used. A large-scale power 
plant will be more efficient than a small 
engine. According to the U.S. Department of 
Energy, well-to-wheel efficiencies (including 
all transition stages, from raw materials to 
motive power at the drive wheels) are 11% 
for gasoline-fueled vehicles versus 17% for 
electric vehicles. So whatever portion of 
its energy a plug-in hybrid took from the 
grid would be half again as efficient as the 
gasoline burned in an internal combustion 
engine (ICE) vehicle. 

If you are going to look at the carbon 
footprint of the grid-supplied electricity of 
the plug-in hybrid and include the power 
plant, then you will also need to include the 
carbon footprint of the gas refinery in your 



calculations for an ICE car, as well as the 
tanker trucks that deliver it. Keep in mind 
that gas refineries use an enormous amount 
of electricity, so some carbon impact from 
the electric power plant would have to 
be applied to the ICE vehicle as well. It 
is inherently more efficient to use the 
electricity to directly power a vehicle than 
to power a gas refinery to make gasoline to 
power a vehicle. 

The scale for greater efficiency (therefore, 
lower pollution and carbon footprint) 
proceeds in this order: gas vehicles to 
hybrids to plug-in hybrids to grid-charged 
pure EVs to renewable-energy-charged 
pure EVs. 

Shari Prange, Electro Automotive • 
Felton, California 




industrial solar 



KEEKERS 



www.affordable-solar.com 



home power 125 /june & july 2008 






Buy panels in bulk and save! 

We offer a variety of panels from 
the best manufacturers. 



Discounts available if you are 
interested in several pallets. 

bp solar 

SX-1 95B, 1 95w, 1 6v, Pallet of 20 

evergreen solar 

ES-1 80, 1 80w, 1 6v, Pallet of 30 

^ KldDCERE 

KD180GX-LP, 180w, 16v, Pallet of 20 

SHARP 

ND-21 6U2, 21 6w, 1 6v, Pallet of 28 

BSUNTECH 

STP1 70S-24Ab-l , 1 70w, 24v, Pallet of 44 

Supplies are limited. 

Pallet quantity varies by manufacturer, please call us for more 
details. If there is another panel that interests you but it's not 
listed here, please contact us. 




Kyocera KD205X-LP 

205 Watt 16V Nominal Solar Module 

Kyocera is leading the solar 
industry with the development of 
the most efficient and cost 
effective systems available. 
Kyocera’s new and improved, 
larger modules feature higher 
output per module and maintain 
the three-bus bar circuitry along 
with d.Blue solar technology. 

Our Price : $ 91 0. 00 




KACO IkW 

Complete Grid Tie System 

The Krannich 1 kW Grid Tie 
system includes almost every- 
thing you need to start using 
power from the sun! System is 
expandable to 1 .7 kW. 

Our Price : $ 6,399. 00 




OutBack FLEXmax 80 

Charge Controller 

The FLEXmax 80 is the latest 
innovation in Maximum Power 
Point Tracking (MPPT) charge 
controllers from OutBack 
Power Systems. 



Our Price : $ 580. 00 




BP Solar SX3200B 

200 Watt 1 6 Volt P V Module 

High-efficiency photovoltaic 
module using silicon nitride 
multicrystalline silicon cells. 

Our Price :$ 91 0.°° 



1 

■J 

fit 1 



SMA SB 7000US 

7000 watt inverter 

Increased efficiency means 
better performance and 
shorter payback periods. 

Our Price : $ 3,953. 00 




Xantrex XW6048- 
120/240-60 

Designed with consultation 
and input from industry ex- 
perts, dealers, and installers, 
the XW sets a new standard 
for battery-based inverter/ 
chargers. 

Our Price : $ 3,485. 00 



Air-X Land 24V 

Wind Turbine Kit 

The AIR-X builds upon what 
has made AIR the world’s #1 
selling small wind turbine with 
new technology previously 
found only in today's state-of- 
the-art megawatt-class wind 
turbines. 

Our Price : $ 606. 87 




*Please note pricing and availability subject to change in this crazy market 

Call now toll free to order your way to a 
Solar Energy Solution at 1 (800) 810-9939 
or email us at sales@affordable-solar.com 

You can also visit us online at vvvvw.affordable-solar.com 



10+ years of experience & service 
you can depend on and trust 

• design • consultation 

• financing • installation 



affordable solar 



Affordable Solar Group, LLC • 2501 Yale Blvd SE, STE 105 • Albuquerque, NM 87106 • (800) 810-9939 • www.affordable-solar.com 





Mailbox 



"I installed a heat 
pump as a companion 
to my more than 90% 
efficient propane 
furnace two years 
ago, and have 
documented overall 
energy savings in the 
25% to 30% range." 



Hybrid Heating System 

As a person who has worked in the HVAC 
industry my entire life, I found your article, 
"Home Heating Options," in HP123 both 
accurate and informative. One option 
that you did not suggest, much to my 
surprise, was the hybrid gas furnace/air- 
source heat-pump system. 

Even in my home state of Wisconsin, 
where the winters are extremely cold, a 
hybrid system is a real energy saver and 
has a very reasonable payback. Standard 
air-source heat pumps are effective for 
home heating with outdoor temperatures 
down to 20°F, depending on the moisture 
content in the air. I installed a heat pump as 
a companion to my more than 90% efficient 
propane furnace two years ago and have 
documented overall energy savings in the 
25% to 30% range. A dual-fuel controller 
operates the furnace automatically when it 
is too cold for the heat pump to be effective. 
Using this combination, my propane 
furnace did not come on until December 
and did not operate after mid-February, 
since the temperatures were above 
24°F — the system's changeover point — the 



majority of the time. On many days during 
the winter, the furnace would run early 
in the morning and the heat pump would 
take over as the daytime temperature rose. 
My heat pump is a standard 11 SEER, R-22 
unit. Newer units coming onto the market 
will offer better efficiency and better heat 
transfer at low temperatures. 

My 2,200-square-foot home has some 
passive solar gain, and I am careful about 
setting back the thermostat. With the 
new system, over the past 12 months, 
I have paid an average of $100 per 
month for propane and $120 per month 
for electricity, including heating or air 
conditioning. This is with propane at $2.25 
per gallon, and electricity at about $0,095 
per KWH. I also installed a Bosch tankless 
water heater, which has contributed to 
my energy savings. 

I enjoy your magazine a great deal 
and have gained much knowledge 
about renewable energy, which I plan to 
incorporate into the next home I build. Keep 
up the good work. I will look for an article 
on hybrid heating systems in the future. 

Mike Henry • Edgerton, Wisconsin 



ABS Alaskan, fnc* introduces: 

Water Turbines 




Run^cf-river design for easy installation 

- No dems, dnrtiSf&M. 04 , «iw^(Wp«!istocfcs r 

Low rotational spaed for safer operation 

- Lets potoftw demise to & totoine btedes 

Easy installation in grid-Intertie & off-grid sites 

- TtiVthVia-i nKluiSt compete fo wrfft' install M 

5 kW, lOkW and 25 fcW systems available 

- ItufWfWfl ssajy apemta in psreHai for larger systems 



For more information abmit FtiCtirretii turbines, visit 
www.tlhsilk.cmtl or contact us offline: 



A ItS Aiaskntt , I nr, 

2I.V Vbn Hen RJ. f - ~1 ■; f 

jt*: m J* i: Wl7 45 1 

(O'; WW-iy-ONHJ 



4 fitS Distribution Center 
i*4 -Usd Swn.Jfcffli'rt. 

P 1151.5745 fiix. J35.il 1. 574S 
tbit f-'trr b IS: 




home power 125 /june & july 2008 





Mailbox 




Moving Toward Energy 
Efficiency 

I just discovered your magazine at the 
library today and was excited to see 
another source of information regarding 
building an energy-efficient home. 

We are hoping to sell our house 
soon. I am being threatened with 
legal action if I hang my clothes on a 
clothesline (see The Wall Street Journal, 
September 18, 2007). 

One thing led to another, and we 
decided rural living is more conducive 
to our lifestyle. We feel this is an 
opportunity for us to build green 
and hang a clothesline without our 
neighbors complaining. 

I look forward to getting great ideas 
for building a new house from your 
magazine. In the meantime, encourage 
your readers to hang their clothes out 
on clotheslines to dry. Clothes dried in 
the fresh air smell great, and you can 
save up to 10% of residential energy use 
by not using your dryer. 

Susan Taylor • Bend, Oregon 



Errata 

In the wiring schematic on page 53 of HP124 
we overlooked the positive grounding 
requirements of the SunPower PV modules. 
The positive (grounded) conductors should be 
white. The negative (ungrounded) conductors 
should be black in this configuration, and 
routed through the array disconnect switch. 
The correct wiring configuration is shown 
below. 



To send a letter to 

Home Power's Mailbox, 
write to: mailbox@homepower.com 

or Mailbox, c/o Home Power 
PO Box 520, Ashland, OR 97520 

Published letters are edited for content and 
length. Due to mail volume, we regret that 
unpublished letters may not receive a reply. 




DC Disconnect 




Bigger, Better and 

Maintenance Free! 



IntxwlDciiiB the NEW L-18 Group Size • DC40O-8 



NOW WITH A 

5-YEAR SOLAR WARRANTY 



From China's Premier Quality 

manufacturer - Fullriver Battery 

Mfg. Co. Ltd. 

• True Deep Cycle Performance 
and Longer Life 

• Perfect for Solar, Back Up 
Power and all RE Applications 

• Non Hazardous - Non Spillable 
Dual Terminals and Handles 

• In stock in warehouses Coast to 
Coast. Other unique models 
and sizes are also available. 



Contact us for a distributor near you. 

phone: 

1-800-522-8191 

e-mail: 

sales@fullriverdcbattery.com 



See our complete AGM battery line up at 

www.fullriverdcbattery.com 



www.homepower.com 








The MidNite E-Panel with two 63 amp breakers 

imilar set up using OB Flexware 500 $1430 list, $ 

(Now save even more) 



ich would you rather have, a nice new shiny box tl 
wall or an even shinier, more compact system, an< 



- — I $933 /_j 

can be diverted 
\ to buy a 
PV panel or < 
18 pairs of shoes 
zn or? ^ 



OutBack mounted on a 

MidNite Solar E-Panel 

$549 list (E-Panel only) 
120VAC version 



Magnum Energy mounted on a 

MidNite Solar E-Panel 

$799 List (E-Panel only) 

1 20/240VAC version 



Check out 

“E-Panels Explained” 
on our website for 
help in selecting the 
best E-Panel for your 
application 



$ 01 / 11 ?, inc 










Made in the USA 



Trust nothing less than top quality American-made PV modules that provide 
more kWh per kW than other major brands. By installing SolarWorld 
Sunmodules, you're getting a superior value - more kWh foryour money. 

In addition to superior performance, SolarWorld Sunmodules are lighter 
weight and feature a sealed junction box with integrated locking connectors, 
which makes them easierto install and completely reliable. 

SolarWorld Sunmodules also carry a 25-year power warranty supported by 
the largest manufacturer in the USA since 1977, so you get long-term 
performance you can count on. 

Maximize the value of your PV installation by using SolarWorld Sunmodules. 
Call 1-866-226-5806 for a distributor nearyou. 



SolarWorld California 

4650 Adohr Lane 
Camarillo, CA 93012 
service@solarworld-usa.com 




SolarWorld 

THE SUNPOWERED COMPANY™ 



SolarWorld. And EveryDay is a Sun Day. 



www.solarworld-usa.com 




Off Shore 

by Derek Young 
photos by Roger Webb 



Some say home is where you 
hang your hat. Michael and 
Joanne Young say home is where 
you hang your PV modules — and 
your wind genny. As they have 
found, you can travel and have all 
the comforts of home by bringing 
along your own power company. 




#hen Mike Young imagined his dream home, his 
/ fantasy included one mast, two sails, a wind turbine, 
ft and a solar-electric system. " I pictured my wife and 
myself on a sailboat surrounded by blue water. I saw us 
enjoying sunrises and sunsets day after day, breathing in the 
salt air while listening to the ocean and watching the sails fill 
with wind," says Mike, a native of Springfield, Vermont. "I 
saw us living independently." 

Fed up with Vermont's cold, dark winters, Mike fell in 
love with the idea of escaping to the warm, sunny Caribbean 
for part of the year. An avid sailor who spent many years 
sailing on Lake Champlain and crewing on friends' boats, he 
had the know-how to pull it off. All he needed was an ocean- 
worthy vessel and a good first mate. "When he first told me 
the idea, I thought he was crazy," says Joanne, his wife of 
40 years. "But he was serious." 

The couple bought Orion — a 37-foot sloop — and 
upgraded its navigational, steering, and safety systems 
for ocean cruising. They sold the family's retail propane 
business and embraced the idea of early retirement at age 
52. In 2000, Mike and Joanne made their maiden voyage to 
the Caribbean islands. From Shelburne, Vermont, they took 
Orion south to the Hudson River, which brought them to 
New York City. From there, they followed the coast south 
to Virginia, where they departed on the 11-day voyage to 
Virgin Gorda. 

Testing the Waters 

The first trip gave newbie cruisers Mike and Joanne the 
chance to get a feel for their energy needs. They left home 
with a diesel engine set up to charge a 12-volt, 366 amp-hour 
battery bank that powered the boat's electrical loads. Though 
the engine worked well for cruising when winds were low 
and produced more than enough energy for battery-charging, 
it was less than ideal for generating energy for their day-to- 



A noisy diesel engine used to spoil the ambiance at dinnertime. 
With their RE systems in place, Joanne and Mike now 
enjoy quiet evenings. 

day needs — lighting, refrigeration, and hot water, and for 
small household appliances, the navigation equipment, and 
communication radios. 

Running the engine a few hours each day to recharge the 
battery bank burns about 1 gallon of diesel fuel — only about 
90 cents on the islands — so it wasn't the expense that bothered 
Mike and Joanne. It was the fumes and the noise. A diesel 
engine likes to be run hard and hot, preferably over long periods 




www.homepower.corn 




sustainable sailing 




Mike and Joanne's two-module PV system 
and wind generator have significantly reduced 
their reliance on the boat's diesel generator. 



with a heavy load. But when it's used as a generator only, the 
engine doesn't operate at its optimal temperature and burns 
inefficiently, producing more pollution per energy output. 

To add insult to injury, the warm Caribbean temperatures 
doubled the energy requirements of the refrigerator and 
freezer — two of the largest and most critical demands on the 
batteries. Because they wanted to avoid paying for electric 
hookups at marinas, Mike and Joanne found that they needed 
to run the engine at least twice a day — about an hour during 
the day and an hour at night — to charge the batteries and 
meet their electrical loads. 

"Have you ever heard or smelled a diesel engine?" Mike 
says. "There was no room in my sailing fantasy for a smoky, 
noisy diesel engine and all its pollution. The engine ruined 
one too many cocktail hours on the deck. I looked around and 
saw other boats with solar modules and wind turbines, and 
knew what I had to do." 




The battery monitor, conveniently located 
next to the other electric controls. 



Sustainability at Sea 

For cruisers, who generally sail in areas where the sun and 
wind are abundant, combining solar and wind power is a no- 
brainer — especially when the alternative is burning diesel fuel 
to charge batteries. "When you use the power of the wind to 
move your home," Mike says, "you feel good. And when you 
can power the rest of your needs with renewable energy, it 
completes the picture." 

In 2003, after talking with fellow cruisers and observing 
different wind turbines at work, Mike purchased a wind 
turbine manufactured by Kiss Energy Systems (KES) in 
Chaguaramas, Trinidad. Designed for marine conditions, 
the KISS (Keep It Simple Sailor) turbine is durable yet quiet 
enough for the confined quarters of a sailboat. Elliptical blade 
ends minimize tip noise, while a 9-foot tower mounted to the 
stern provides plenty of headroom — nearly 7 feet. 

Mike and Joanne saved on labor costs by installing the 
turbine themselves. Instead of using the mast mount kit 
offered by KES, they fashioned a mount from stainless-steel 
pipe — which cut costs some but added hours to the project. 
"Measuring, cutting, and fitting the turbine mount took 
several days. What made the installation more difficult was 
that we did it at anchor. It would have been much easier if the 
boat was on land or docked, but we managed," Mike says. 

Three blades make up the 58-inch-diameter rotor. 
The aerodynamic fiberglass two-piece housing is hand- 
molded in KES's Chaguaramas shop, as are the blades. 
The manufacturing of the three-phase, permanent-magnet 
alternator is subcontracted to local fabricators. The alternator's 
three-phase AC output is, in turn, converted to DC for battery 
charging. In typical 15-knot (17.3 mph) winds, the turbine 
can produce up to 7.5 amps for the 12-volt nominal battery 
bank. If batteries are full, the wind genny can freewheel or an 
electrical brake can minimize the rotation in winds up to 30 
knots (34.5 mph). Stronger winds require the freewheel mode, 
and a thermal switch reduces the output and prevents the 
alternator from overheating. 

Because the turbine does not include additional regulation 
other than the thermal switch, manually furling the turbine 
is necessary to prevent excessive battery voltages. Mike does 



home power 125 /June & july 2008 






sailing 



Young Off-Grid PV & Wind System 






Photovoltaic Array: 

Two, Shell SQ80, 

80 W each at 17.5 Vmp, 
wired for 160 W total 
at 17.5 Vmp 



WindTurbine: 

KISS, 58-in. rotor diameter, 

7.5 A at 12VDC at 15 knots (17.3 mph) 



DC Array 
Disconnect: 

15 A 

breakers 



1 1 


i — 


:d : 


) 



j v. 



DC 

Load 

Panel 






Charge Controller: 

Morningstar SunSaver, 10 A 



• SunSaver-io 




Battery Bank: 

12VDC, 
366 AH total 



Inverter/Charger: 

Xantrex Freedom Marine 10, 
1,000 W, 12VDC input, 

120 VAC mod. square-wave output 



AC Load Panel: 

To 120 VAC loads, 
automatic 
neutral/ground 
bond internal to 
inverter 





Battery/ Inverter 
Overcurrent 
Protection: 

200 A, classT fuse 



Note: All numbers are rated, manufacturers' specifications, or nominal unless otherwise specified. 



PV & Wind Systems Tech Specs 



Overview 

System type: Battery-based solar- and wind-electric 

Location: New England to Trinidad 

Solar and wind resource: Varies with location 

Photovoltaics 

Modules: 2 Shell SQ80, 80 W STC, 17.5 Vmp 

Array: Two modules in parallel, 160 W STC total, 17.5 Vmp 

Array installation: Self-fabricated flush mounts made from 
stainless-steel tubing, installed horizontally over the boat's 
cockpit 

Orientation: Varies with the movement of the boat 

Wind Turbine 

Turbine: KISS (Keep it Simple Sailor) 

Rotor diameter: 58 in. 



Rated energy output: 7.5 A, 12 VDC nominal, at 15 knots 
(17.3 mph) 

Rated peak power output: 25 A at 12 VDC nominal 

Mount: Home-built stainless-steel pipe, rubber-mounted on 
the stern 

Energy Storage 

Batteries: Two Deka 8G4DM, 12 VDC nominal, 183 AH, 
sealed gel 

Battery bank: 12 VDC nominal, 366 AH total 

Balance of System 

Charge controller: Morningstar SunSaver, 10 A 

Inverter: Xantrex Freedom Marine 10, 1,000 W, 12 VDC 
nominal input, 120 VAC modified square-wave output 

Battery capacity metering: CDM Systems BT2000 



www.homepower.corn 







Living the good life. 

not worry too much about overcharging the batteries, since 
he's never far from the boat for long. On the rare occasion 
when the turbine needs a break or, in trade winds, makes 
too much noise, he stops the rotor manually by switch. "If 
we're lucky enough to make that much 
energy, it's time to do some ironing, 
use the microwave, or make some other 
use of it," he says. 



Off-Grid Self Sufficiency 

"When traveling in remote places, you are forced to become 
a jack of all trades — an electrician, plumber, diesel mechanic, 
and handyman, all in one," Mike says. "My best defense is to 
be prepared for anything. I've done my research, and I can 
handle most repairs that arise. So far, so good." 

Mindful of the elements, Mike took extra care when 
wiring both the wind- and solar-electric systems — twisting, 
taping, and heat-shrinking all connections. "The salt air can 
be brutal on mechanical systems of any kind," he says. "So 
long as the wire connections are sealed properly, then you 
have very few problems and the systems are easy — virtually 
maintenance free." 

Well, almost. . ."There are a lot of seagulls, and we have to 
clean the droppings off the modules. If we're lucky enough to 
have fresh water, then we just hose off the modules now and 
again," he says. "But it's not so bad. I'll take bird droppings in 
the Caribbean over Vermont's snow and ice any day." 

Thanks to their wind- and solar-electric systems, Mike 
and Joanne enjoy all the comforts and conveniences of home 
with cleaner, quieter power sources. "Solar does great in 
the daytime," Mike says, "but at night, when energy needs 
are much higher, the wind takes over." The sun is fairly 



Indoor lighting and television, powered by renewable energy. 



Because the position of the boat is always changing and 
shadows are inevitable, the placement of the modules is not 
critical to the system's overall performance. "On a boat, it's 
usually a matter of finding free space where the modules 
are out of the way and won't get damaged," says Mike, who 
chose not to tilt the modules, and instead, flush-mounted 
them to the bimini frame. "I probably could have gotten 
slightly better performance if I'd made the mount adjustable, 
but the sun is so strong and the days are so long here that the 
slight gain didn't seem all that important." 



Solar in Safe Harbor 

"It's a double-edged sword with wind," 
Mike says. "We like the wind, and we 
need the wind, but we also like to get out 
of the wind." Before, anchoring in low- 
wind spots or seeking shelter in harbors 
meant that the couple had to rely on the 
diesel generator. For that reason, Mike 
chose to supplement the wind generator 
with a simple solar-electric system — two 
Shell 80-watt PV modules mounted 
horizontally on the bimini (awning) over 
the cockpit. He purchased the modules 
from Marine Warehouse in Trinidad, 
and sourced from a local hardware 
store the electrical cabling and other 
parts — stainless-steel tubing, mounting 
brackets, and nuts and bolts that resist 
the corrosive effects of salt water. 



home power 125 /june & july 2008 



consistent, but when there is not adequate wind, Mike and 
Joanne still must offset energy usage by running the engine 
to charge the batteries. On its own, the solar-electric system 
produces about 55 amp-hours (AH) per day on average — shy 
of their 70- AH usage. "One more PV module, and we'd be 
perfect," Mike says. "I just need to make room for it." 

Currently, the 12-gallon hot water tank is fitted with a 
heat exchanger that uses waste heat from the diesel engine 
to heat water for domestic use. When Mike and Joanne need 
to replenish the hot water, they run the engine, usually every 
third day for about an hour. Though the engine only burns 
about a half gallon of fuel — about 45 cents' worth — in that 
hour, that's one hour and one half gallon too much for Mike. 
He has devised a plan to add a custom solar hot water system 
off the stern. Tapping into the existing plumbing will be fairly 
easy, he says, but coordinating the shipping of the unit to the 
islands will require some patience. "This," he says, "is the last 
piece. Then we'll be totally independent." 

On the Horizon 

For the past eight years, Mike and Joanne have spent every 
winter island-hopping around the Caribbean. By living 
simply and relying on renewable energy, they keep their 
expenses down. They anchor at out-of-the-way places and 
catch their dinner most nights. One yellowfin tuna feeds the 
couple for days, and they trade what they can't store for other 



sustainable sailing 

goods. Though the couple only saves an estimated $15 per 
week by offsetting their diesel fuel use, every dollar helps 
perpetuate their cruising lifestyle. 

For the rest of the year, the couple returns to their home 
in Springfield, Vermont. "We have the best of both worlds 
right now," Joanne says. "When this all started, he had to 
drag me down here kicking and screaming, but now I love 
this lifestyle — seeing all the different places, meeting the local 
people, and hanging out with fellow cruisers. Living by the 
wind and the sun — I wouldn't have it any other way." 

Access 

Derek Young (seagoatmusic@gmail.com) is a freelance writer and 
musician who dabbles in renewable energy. He lives in a solar- 
powered camper in an undisclosed, off-grid location in Vermont. 

System Components: 

East Penn Manufacturing Co. • www.eastpenn-deka.com • Deka 
batteries 

Kiss Energy Systems • www.kissenergy.com • Wind turbine 
Morningstar • www.morningstarcorp.com • Controllers 
SolarWorld • www.solarworld-usa.com • PV modules 
Xantrex • www.xantrex.com • Inverter/charger 




gro Solar 



What the World Needs. NOW* 



Do flat roofs torment you? 

Are flat roof mounting system lead times and 
customer service issues causing you heartburn? 
Would you like to install more product faster? 




PanelClaw™ has heard you! 

Developed by a leading installer and exclusively distributed by groSolar. 



Stop the torment! 

Coming soon... 

Call us for more information: 

8oo CO SOLAR (800.467.6527) groSolar.com PanelClaw 



■ ® 

gro 

brilliant energy 
solutions™ 



www.homepower.corn 





♦ MITSUBISHI 
ELECTRIC 

SDLAR ELECTRIC INNOVATIONS 




powered by the sun 



With more than 33 years of experience in the 
solar electric industry, Mitsubishi Electric is an 
industry leader in developing high-efficiency 

photovoltaic modules that deliver clean, 
reliable energy to homes and businesses. 



Mitsubishi Electric has made a commitment to 
protecting the environment and we are proud 

to use 100% lead-free solder in our solar 
panels. For more information, please call 
714-220-2500 or visit our website: 

www.mitsubishielectricsolar.com 






Solahart has been 
designing and building 

Hot Water Free from the Sun 



solar water 
heaters since 
1953. The Solahart 
brand is backed by 
Rheem, the leading 
water heater 
manufacturer 
in the world. 

• Simple and reliable 
passive thermosiphon 
systems 

• Open and closed 
loop systems for 
installation in almost 
any environment 

For more information 

on Solahart systems 
and dealers, call 

334 - 260-1525 
or email us at 

solar@rheem.com 



Dealer inquiries 
are welcomed! 








Hot Water Free from 
the Sun™ is a trademark 
of Solahart Industries 
Pty Ltd 




Solar 
Water Heaters 
built by Solahart 
and backed by 
Rheem! 




Solahart systems 
QG-300 certified by SRCC 



Rheem Water Heating | 101 Bell Road | Montgomery, AL 36117-4305 | www.rheem.com 



RH 120607 







Average Annual Rainfall 

| More than 96 inches 
H 64 to 96 inches 
EH 32 to 64 inches 

□ 16 to 32 inches 

□ 8 to 16 inches 

□ Less than 8 inches 



Adapted from Design for Water 
by Heather Kinkade 



ike it or not, drought is becoming more common in 
many parts of the country. As dropping water levels 
b n rivers and aquifers put the squeeze on freshwater 
stores, municipalities are tightening their belts, raising 
rates, and even implementing water-use restrictions. This 
past spring, Raleigh, North Carolina, residents and others 
in six surrounding towns were under "stage 2" water 
restrictions — no lawn sprinkling, no car washing, and no 
pool filling. Similar curbs are becoming more prevalent 
across the country. 

Even those who rely on well water aren't escaping the 
consequences, as underground water tables drop below the 
reach of many wells. In 1999, a drought in the Northeast 
lowered water levels below their pumps in hundreds of wells 
in two New Jersey counties. Three years later, the prospect 
of parched wells pitted farmers against city dwellers of 
Cheyenne County, Nebraska, in an effort to secure water. 
And the situation is not getting better. According to a 2007 
report by the U.S. Geological Survey, underground water 
supplies all over the United States are continuing to shrink. 

Some people are looking to the skies: catching and storing 
rainwater. A rainwater harvesting system can reduce the need 
and cost to pump groundwater, and can be less expensive 
than tapping other water sources. It also provides a close-by 



water supply that contributes to self-sufficiency. Rainwater is 
"soft" water that's low in mineral content, which helps reduce 
buildup in your home's plumbing. In coastal areas where 
saltwater intrusion into aquifers is a problem, catchment 
becomes even more important. And, in some places, installing 
a rainwater system makes you eligible to receive rebates for 
reducing your use and dependency on municipal water. 

System Components 

Rooftop rainwater harvesting systems are easy to construct, 
operate, and maintain. Whether it is large or small, a rainwater 
harvesting system has six basic components: 

1. Catchment area: The surface upon which the rain falls, 
generally a roof or impervious pavement. 

2. Conveyance: The channels or pipes that transport the 
water from the catchment area to storage. 

3. Roof washer: The systems that filter and remove 
contaminants and debris, includes first-flush devices. 

4. Storage: The tanks where collected rainwater is stored. 

5. Distribution: The system that delivers the rainwater for its 
end use, either by gravity or pump. 

6. Purification: The equipment that filters and distills, as well as 
additives that filter and disinfect the collected rainwater. 



home power 125 /June & july 2008 




catching rain 



Catchment Area 

Although rainwater harvesting for nonpotable use can be 
accomplished with any type of roofing material, for potable 
use, the best roof materials are metal, clay, or concrete. 
Water for drinking purposes should not be collected from 
roofs containing zinc coatings, copper, asbestos sheets, 
lead, or asphalt compounds. For flat or semi-flat roofs, an 
acceptable roofing material for potable water catchment 
systems is Weather Barrier Raincoat 2000 (www.haleypaint. 
com), a coating product approved by the National Sanitation 
Foundation (NSF). 



Catchment Area 




Length (ft.) x Width (ft.) x Annual Rainfall (in.) x Surface Area 
Efficiency x 7.48 gal./ft 3 = Annual Catchment Area Runoff (in gal.) 



A rainbarn describes an open-air shed with a large roof 
area to catch rainwater. The structure can also provide 
shelter for a variety of uses — a patio, carport, hay storage, or 
farm equipment storage — thereby serving multiple functions. 
Typically, the rainwater storage cistern is housed under a 
rainbarn. 

The quality of the captured rainwater depends, in part, 
upon catchment texture: The best water quality comes from 



Rainwater Regs 

Several communities are enacting regulations and 
guidelines for dealing with rainwater harvesting. In 
Arizona, the towns of Tucson, Flagstaff, Chino Valley, 
and Pason have enacted ordinances encouraging the 
use of harvested rainwater. In Washington state, Seattle 
and Friday Harbor, as well as King County, have recently 
established their own guidelines. 

Currently, the American Rainwater Catchment 
Systems Association is working with several national 
organizations to come up with general ordinances that 
communities can revise and adopt. Texas has state 
legislation dealing with rainwater harvesting and, along 
with Hawaii and Virginia, offers rainwater harvesting 
guideline booklets (see Access). 

The Uniform Plumbing Code has an appendix dedicated 
to rainwater systems, with sizing guidelines for gutters, 
downspouts, and lateral pipes. The applicable plumbing 
code should be reviewed for any design of rainwater 
conveyance systems. 



smooth, impervious catchment or roofing materials. Quality is 
also determined by rainfall pattern and frequency. The greater 
the storm event (i.e. the rainfall extent) and the shorter the time 
between storms influence the cleanliness of the catchment area. 
Greater rainwater volumes and frequencies will transport fewer 
pollutants to the first-flush device and to storage. 

Rainwater is slightly acidic, which means it will dissolve 
and carry minerals into the storage system from any catchment 
surface. For systems intended for potable water, first test the 
water collected from the proposed catchment surface to 
determine its contents. In some cases, filtration can remove 
some contaminants. In other cases, the catchment surface 
must be reevaluated or amended. 

Conveyance 

A common rainwater conveyance system features gutters 
with downspouts that direct rain from rooftop catchment 



Roof Surfaces for Potable Gaichmeni 



Yes — Painted metal Yes — Ceramic or concrete No — Wood shingles No — Asphalt No — Galvanized or copper 




www.homepower.corn 




catching rain 

surfaces to cisterns or storage tanks. The materials for gutters 
and downspouts range from vinyl and galvanized steel to 
aluminum, copper, and stainless steel. At a minimum, 
gutters should be 5 or 6 inches wide, with an outer edge 
higher than the roof-side edge and splash guards at roof 
valleys. Gutters should slope toward downspouts at 1 /16 
to 1/4 inch per 10-foot length of gutter, and be installed 
per manufacturer's guidelines for hangers and connection 
points. 

Downspouts should have 1 square inch of outlet 
(downspout) for every 100 square feet of roof area 
to be drained — a 4-inch-diameter downspout can drain 
approximately 400 square feet of roof area. Add more or 
larger downspouts for larger collection areas. A typical 
connection material from a downspout to a cistern is a 3- or 
4-inch-diameter, schedule 40 PVC pipe or ABS pipe, which is 
considered a more environmentally friendly plastic. However, 
for potable rainwater collection, PVC or stainless steel should 
be used. It is made from new material, not recycled material 




Leaf screens are the 
first defense in keeping 
debris out of your system. 



What’s a Rain Head? 

The filtering process can be augmented by using a rain 
head — a downspout that incorporates a self-cleaning 
system. This unit has a funnel topped by a screen, which is 
set at an angle of about 33 degrees to the lower horizontal 
edge of the funnel. As the water washes over the angled 
screen, the debris is forced toward the screen's lower 
edge and away from the building, while most of the 
rainwater continues through the funnel screen. 




that may have picked up contaminants from its previous 
use. Coated aluminum downspouts are also acceptable for 
potable water collecting. Avoid ABS, DWV PVC, copper, 
lead-containing, or galvanized pipes. 

To keep leaves and other debris from entering the system, 
the gutters should have continuous leaf screens made out of 
1 /4-inch wire mesh or an equally efficient product covering the 
entire length of gutter. Installing leaf screens will help reduce 
system maintenance, reduce mosquito-breeding habitat, and 
eliminate the need for frequent ladder-climbing to clean the 
gutters. Downspout filtering rain heads, such as the Leaf 
Beater and the Leaf Eater, provide a second chance to capture 
and remove debris that might enter a storage system. 



First-Flush Diversion 



Downspout: 

From gutter 




40 



home power 125 /june & july 2008 





catching rain 



Basic Potable Rainwater Catchment System 




Roof Washing 

Roofs, like other large, exposed areas, continuously receive 
deposits of debris, leaves, silt, and pollutants on their surfaces. 
One or several components can be used to filter or collect 
debris and soluble pollutants, including gutter leaf-guards, 
rain heads, screens, and/or first-flush devices. First-flush 
devices are important when rainwater is collected without 
the use of gutter leaf-guards, leafslides, or rain heads, or if the 
rainwater is to be used for human consumption. 

The simplest roof-washing system is a first-flush device 
that consists of a standpipe (the diversion chamber for 
collecting the initial rainwater runoff) and a gutter downspout 
located prior to the cistern or storage tank inlet. When the first 
rainfall enters the standpipe, the pipe fills, and a floating 
ball seals the entrance to the diversion chamber, sending 
rainwater to the cistern. Because a typical standpipe does not 
automatically outlet to a storm drain, a screw-on cleanout 
plug should be located at the end of the standpipe. If it is not 
the self-draining variety, the standpipe should be emptied 
after each rain event. This will eliminate standing water 
from becoming foul from debris and soluble pollutants, and 
thereby contaminating future collected rainwater. 

Another diversion device is a roof washer, which consists 
of a 30- to 50-gallon box, with leaf strainers and a filter, placed 
just ahead of the storage tank. Several models of roof washer 
are commercially available. Regardless of which type you use, 
cleaning the washer is imperative. Otherwise, clogging can 
result, restricting the flow of rainwater, and the stagnant water 
can encourage pathogen growth. 



Storage 

Cisterns or storage tanks represent the largest investment in a 
rainwater harvesting system, since already-existing buildings 
have most of the other components: a roof, gutters, and 
downspouts. 

Above-ground tanks are available at most farm-supply 
and building centers. They allow for easy inspection and 
water extraction /draining by gravity. However, they also 



A storage tank with a SafeRain first-flush diversion valve, 
which operates on flow rate instead of initial quantity. 




www.homepower.corn 



41 





Courtesy Heather Kinkade 



catching rain 




Rainwater Harvesting Costs 

Typical Capacity 



A. 


Collection 


Estimated Cost 


/Size 


1 




Gutters 


$0.30-$12.00 
/lineal ft. 


— 



Roof Washing 



This 8,800-gallon, galvanized storage tank requires a lining to 
make it suitable for potable water. 



take up yard space, can be expensive, and are susceptible 
to damage from constant exposure to the elements. Below- 
grade storage systems generally are reasonably priced, 
although you'll have to budget for excavation expenses. They 
require little or no above-ground space, and permit thinner 
cistern walls due to the support of the surrounding ground. 
However, extracting water from below-grade systems is more 
difficult — requiring a pump unless a tank is buried on a hill 
above its end use — and leaks and failures are more difficult to 
detect. In addition, tree roots or overhead traffic may damage 
a below-grade storage system. 

Whether you go with above- or below-ground, a cistern 
that is kept cool and devoid of sunlight allows water quality 
to increase with time. When photosynthesis cannot take place, 
most organisms die as their food source is eliminated. With 
each rain event, a new supply of sediment and organisms 




A variety of pumps 
are acceptable 
for rainwater 
distribution. This 
submersible pump 
has a floating 
intake to avoid 
sediment on the 
bottom of the tank. 



Vertical or horizontal 
box roof washers 


$460-$ 1,000 


— 


Storage 


Precast concrete or 
ferro-cement tanks 


$0.35-$1 .50/gal. 


Any 


Fiberglass 


$0.50-$2. 00/gal. 


500-20,000 gal. 


Steel, corrugated & 
galvanized with liner 


$0.30-$2.79/gal. 


150-104,000 gal. 


Polyethylene 


$0.50-$1. 90/gal. 


210-5,000 gal. 


Polypropylene 


$0.35-$1. 00/gal. 


290-20,000 gal. 


Welded stainless steel 


$0.80-$4.00/gal. 


Any 


Wood 

(treated, with liner) 


$0.88-$2. 06/gal. 


Any 


Stone 


Up to $1.00/sq. ft. 


Any 


Invisible structures 
underground retention 
reservoir 


$8.00/cu. ft. 


Any 


Atlantis underground 
storage tank 


$4.84-$5.15/cu. ft. 


Any 


Conveyance 


Prefilters 


$50-$80 


— 


Pressure tanks 


$200-$1,000 


— 


Pumps 


$500-$600 


0.75-1.00 hp 


Filtration 


Cartridge filter sets 


$100 


— 


1-micron filter 


$265 


— 


Reverse-osmosis filters 


$400-$1,500 


— 


UV filters 


$300-$1,000 


— 


Ozone disinfection 
system 


$700-$2,600 


— 


Chlorine disinfection 
systems 

(automatic dosing) 


$600-$1,000 


— 


Chlorine disinfection 
system (manual dosing) 


$1. 00/dose 


— 



will enter the storage unit. The sediment, while not usually 
unhealthy, can initially discolor and flavor the water, but will 
ultimately settle to the bottom of the storage container. It is 
best to remove water from a cistern or tank at a position that 
is farthest from a runoff inlet to allow settling before the water 
is used. Some storage containers may require baffles, inflow 
smoothing filters, or turbulence dissipaters to slow remixing 
with the aged water. 

Distribution 

Stored rainwater may be conveyed (or distributed) by 
gravity or by pumping. If a tank is located uphill or 
above the point of use, gravity may work. Most plumbing 
fixtures, appliances, and drip irrigation systems require at 



home power 125 /June & july 2008 









catching rain 



least 20 pounds per square inch (psi) for proper operation. 
(Standard municipal water pressures are typically in the 
40 psi to 80 psi range.) As a general rule, water gains 1 psi 
of pressure for every 2.31 feet of rise, which would mean 
positioning a storage cistern almost 100 feet above the house 
to achieve typical household pressure. 

In most installations, placing a tank above its point of use 
will also place it above the source, which is often the roof of 
the building where the end use is. Because of this, pumps, 
rather than elevated tanks, are typically used to extract both 
below-grade and above-grade stored water. Submersible 
or at-grade pumps may be used in any rainwater storage 
system. Self-priming pumps with floating screened intakes 
and automatic shutoffs — for times when water levels are 
insufficient — are recommended. 

Generally, well pumps or any type of submersible 
pumps, as well as a pump located outside the tank, can 
be used to transfer the rainwater out of a tank. Some 
pumps keep the line pressurized, eliminating the need for a 
pressure tank. When the rainwater is brought into a house, a 
pressure tank is typically used in combination with a pump. 
Using a pressure tank saves wear and tear on the pump by 
reducing its run-time. 

Purification 

Rainwater intended for human consumption (potable) should 
be screened, settled, filtered, and disinfected. When stored 
water is being used, sediment filtration should be a maximum 
of 5 microns, followed by a 0.5-micron carbon filter or an 
equivalent 1 -micron absolute filter. These ultrafilters should 
be NSF approved for cyst removal, since youTl want them to 
remove disease-causing giardia and Cryptosporidia. 



Specifically designed for potable rainwater filtration, 
the AquaEst RainPC MK II removes bacteria, and organic 
and inorganic contaminants. 




Solar Purification 

Solar water distillation systems are among the 
simplest water purification systems available. No 
filters or membranes are required, no moving parts 
are used, and no electricity is needed. 

Solar stills have a shallow pan with a sloping glass 
cover. Water is directed to the pan where it is heated 
by the sun. The water evaporates from the pan, rises, 
condenses on the underside of the glass cover, and 
runs down its slope into a collection trough and 
into a clean container for storage. The contaminants 
left behind in the pan should be flushed regularly. 
Solar stills can be mounted on roofs or on ground 
structures. 




Most common filters are designed to be used with 
municipal supplies and do not have a convenient method of 
monitoring when they have become overloaded and are due 
for replacement. For safety's sake, filters connected to a cistern 
system should be changed more frequently than suggested by 
the manufacturer. Rainwater used for potable systems should 
be lab-tested periodically for quality. 

Access 

Heather Kinkade is a land-use planner, LEED accredited professional, 
and registered landscape architect in Arizona, and the author of the 
award-winning Forgotten Rain. She is president of Forgotten Rain 
LLC, a rainwater harvesting and stormwater reuse company. This 
article was adapted with permission from her most recent book on 
rainwater harvesting, Design for Water ( New Society, 2007). 



www.homepower.corn 






Clean energy made ...clean! 

Our commitment to clean energy goes 
way deeper than just the quality inverters 
we manufacture. Our entire corporation is 
dedicated to implementing and innovating 
green business practices from the inside out. 



You see, we believe clean energy 
products should be made with clean 
energy. KACO’s onsite PV systems 
generate more than 100% of the 
electricity that we use on an annual 
basis. Our onsite Biomass Com- 
bined Heat & Power Plant provides 
1 00% of our heating needs. 






KACO also provides employees 
free public transportation passes, 
electric vehicles and bicycles for 
their commute. We have even 
started to plant trees to further 
meet our goal of carbon neutral 
manufacturing. 

We believe quality clean energy 
components should be made clean. 

Learn more about our commit- 
ment to clean energy and other 
important company develop- 
ments at www.kacosolar.com/zero 
emissions.php 





www.kacosolar.co 

415 . 931.2046 



KACO 





It's not only a quality promise, it's a 






If 




T ^ i 






1 














1 i I 
















i 


MBiW 











-j 




i fit y i 







Our passion for solar energy has made us a world 
leader in the field. State-of-the-art designs and rigorous 
quality control result in products that meet the highest 
international standards. We deliver increased energy 
efficiency and environmental benefits, backed with 
dedicated service. Because with Suntech, you can rely 
on the product and on the people. 



B SUNTECH 

Solar powering a green future ™ 



www.suntech-power.com 





Climbing the 
Energy Everest 



The Ups & Downs of 

Creating a Net Zero-Energy Home 

by Mel Tyree 




6 



home power 125 /june & July 2008 




! : U \ ■ I Li 

r ■ 



The Tyrees' barn 
was designed 
to perfectly 
accommodate a 
10 KW PV array. 



carbon free 

Living plants rely on solar energy 
as their primary energy source, so 
why not a house? In July 2000, my 
wife Charleen and I set our sights 
on building a net zero-energy 
home. Our goal was to demonstrate 
that you can operate a comfortable, 
modern home — even in a climate- 
challenged location — without 
burning anything. 



I 




A t the start of the project, I was inexperienced in 
building design. But I had spent much of my 
career in biophysics immersed in numbers and 
calculations, working to quantify the exchange of energy and 
matter between sunlight, the environment, and plants. When 
I began running energy systems design calculations for our 
new home, I was amazed by how well my years of seemingly 
unrelated research had prepared me for the journey ahead. 
Along the way, we had to overcome some unique regulatory 
and technical challenges, but, in the end, patience and 
determination gave way to a carbon-neutral home that 
derives 100% of its energy from the sun and wind. 

The motivation to build our zero-emission home came 
from the desire to reduce our contribution to global warming 
and pollution. That meant eliminating our home's dependency 
on all conventional fuels. Homes with solar- and wind-electric 
systems commonly rely on natural gas, propane, heating oil or 



firewood for cooking, as well as water and space heating. We 
wanted to prove that it is possible to live in a home that offsets 
100% of its energy with renewable, nonpolluting sources. 

The first step was to find a location for our new home. 
Over several months, we came across four suitable properties 
in our home state of Vermont, but our potential neighbors 
were opposed to the notion of having a wind turbine in their 
backyard. Eventually we widened our search to the North 
Country of New York, where we found a beautiful, affordable 
property that met our needs — 102 acres of forest and pasture, 
in Ellenburg, just north of Adirondack Park at 44.9° north 
latitude. 

New York state's net-metering law for residential RE 
systems allowed excess energy credits to be carried forward 
to the end of the annual billing cycle and supported property 
tax exemptions for the systems' value. In addition, the New 
York State Energy Research and Development Authority 



www. homepower . com 



r A 






carbon free 




Erecting the tower — 10 feet at a time. Final section — 120 feet up. Hoisting the rotor. 



(NYSERDA) offered generous financial incentives for both 
PV and wind systems. Based on some initial conversations, 
neighborhood support for wind generators seemed positive. 
I also learned that the town of Ellenburg has no zoning 
regulations that prevent erecting a 120-foot tower for the 
wind genny. Our project's future looked bright. We closed on 
the property in October 2003 and were on our way. 

Our Big Picture Energy Plan 

Offsetting 100% of our energy needs would be no small 
feat given the cold, cloudy winters and humid summers 
in Ellenburg, which sits about six miles from the Canadian 
border. Key to our plan was a ground-source electric heat 
pump for space heating and cooling (see "Get Pumped" 
sidebar). Producing the electricity needed to run our heat 
pump — an estimated 7,400 kilowatt-hours per year — would 
require substantial RE generation capacity. And while our 
heat pump is also designed to assist in domestic water heating, 
we'd still need to generate about 3,000 KWH annually for our 
tank-style, backup electric water heater. Even though using 
energy-efficient appliances and lighting would help keep the 
remainder of our loads to a minimum, our annual electrical 
load still came close to 17,000 KWH. 

Because net-metering eligibility in New York limits the 
size of residential PV systems to 10 KW, we planned to 
add a 10 KW wind turbine to the 10 KW PV array. Based 
on our site's solar and wind resources, this hybrid system 
was projected to offset 100% of our home's energy use. Ice 
storms can cause extended power failures in our area, so we 
wanted a grid-tied PV system with battery backup, which 
would supply electricity for the critical loads: an emergency 
backup oil furnace, well pump, refrigerator, some lights, and 
a microwave. 



Working the System 

Our plan was to install wind and PV systems prior to building 
the house, and we didn't want to waste any time. Within 
days of closing on the property, we contracted Sustainable 
Energy Developments Inc. (SED) of Ontario, New York, to 
install a 10 KW Bergey wind generator on a 120-foot tower. 
But, in all the excitement, we overlooked a few critical details. 
Apparently, our local power company. New York State 

Even just the rotor assembly of the 
10 KW Bergey is big and heavy. 







home power 125 /June & july 2008 




carbon free 



Electric & Gas Corp. (NYSEG), was not very supportive of 
on-site residential power generation. Even more sobering, 
at that time, was that New York's residential net-metering 
legislation for wind systems was not as favorable as it was for 
PV systems. We would be credited only 4.2 cents per KWH 
for excess energy our wind turbine produced but would have 
to pay 17 cents per KWH for this "premium" electricity when 
we needed to buy it back from the utility. 

Another hurdle came when we discovered that the state's 
property tax exemption for solar- and wind-electric systems 
was voluntary, and that our local tax authority was one of the 
few in the state that had opted out of the program. Based on 
the full-retail value of our planned RE systems, the associated 
property tax payment would amount to $3,000 per year. By 
the numbers, our project made little economic sense. But we 
weren't going to give up that easily. 

We became frequent faces at city council and school board 
meetings, grabbing anyone and everyone's ear whenever we 
could to make our case for reversing the property tax policy. 
For all our effort, we did persuade the local tax assessor to 
add a new stipulation that the property taxes for each new 
system would not exceed $227 per year — versus the $3,000 
we had originally projected. Other good news was that the 
New York state legislature was on board to approve a bill 
that restructured the net-metering rules for wind energy. 
According to these rules, which went into effect in 2006, we 
would get full retail value for excess energy produced in any 
given year, provided that the energy credits were used within 
the same 12-month period. With the dollars-and-cents side of 
things looking more promising, we decided to proceed with 
our project. 

Wrangling the Wind 

Due to all of the regulatory hurdles, it wasn't until August 
2005 that the Bergey wind generator was up and spinning. 
The actual wind turbine installation went very smoothly. 
SED did a fantastic job assembling the tower, turbine, and 
balance of system components. However, we couldn't find 
an appropriately sized crane within any reasonable distance 
from the site to lift a pre-assembled tower. The resulting 
section-by-section installation of the tower using rigging and 
a gin pole turned out to be one of the highlights of the project 



Get Pumped 

The ground-source heat pump that heats and cools our 
home — and supplements domestic water heating — is our 
biggest load, consuming almost half of the electricity our RE 
systems generate. This amount might sound high, but it's 
actually quite low because of the high efficiency of the heat 
pump and its ability to take advantage of ground temperature. 
If we burned carbon-fuel (like oil or natural gas), the heating 
load would account for 72% of our home's total energy 
consumption. 

Since our goal was to reduce our carbon footprint to zero, 
fossil-fueled appliances were out. Electric resistance heating 
would have been an option, but ground-source heat pumps 
deliver heat with less energy input. A ground-source heat 
pump takes advantage of the relatively constant temperature 
below frost level in the ground — transferring ground heat to 
the home in the winter and the home's heat to the ground 
in the summer. These systems put out a lot more heat 
energy than the amount of electric they consume (300% 
plus), even on the coldest of winter nights. In our system, for 
every 4.3 KWH of energy sent to the house, the compressor 
consumes just 1 KWH for an overall efficiency of 330%. (For 
more on heat pumps, see "Heat from the Earth — A Heat 
Pump Primer" in HP98.) 



Heat Exchanger: 

Refrigerant to 
potable water 
and air 



Compressor ( • 

Heat Exchanger: 

Groundwater to 
refrigerant 

~50°F 




40°F 



Source Well: 

190 ft. deep 



Dump Well: 

220 ft. deep 



for me. 

Anyone with long-term experience with home-scale wind 
systems will tell you that the technology isn't for the faint- 
hearted, and my experience mirrors this seasoned perspective. 
Compared to low-maintenance PV modules, which have 
no moving parts and typically carry 25-year warranties, 
wind turbines are inherently reliant on rotating parts that 
are exposed to some of the harshest conditions imaginable. 
Turbines have a tough job to do and, over time, can fail. While 
our wind turbine installation went without a hitch, some 
technical issues with the system still lay ahead. 

Not all wind turbines, inverters, and their use together in 
a given system will produce similar results when it comes to 
producing energy. In our system, on days where wind speeds 




www.homepower.corn 





carbon free 



tech specs 

Overview 

System type: Grid-tied, solar- and 
wind-electric with battery backup 

Location: Ellenburg, New York 

Solar resource: 4.3 average daily 
peak sun-hours 

Average annual PV system 
production: 10,400 AC KWH 

Wind resource: 12 to 13 mph average 
wind speed 

Average annual wind system 
production: 8,800 AC KWH 

Utility electricity offset: 100% plus 

PV System 

Modules: 80, BP 3125, 125 W STC, 
17.6 Vmp 

Array: Five subarrays of 16 modules 
each, four modules per series string, 
70.4 Vmp, 10 KW STC total 

Array installation: UniRac SolarMount 
racks on south-facing roof, 45° tilt 

Array combiner box: Five OutBack 
PSPV with four 15 A breakers each 

Batteries: 36 Rolls Surrette KS-21, 

2 VDC nominal, 1,000 AH at 20-hour 
rate, flooded lead-acid 

Battery bank: Three series strings, 
3,000 AH total at 24 VDC nominal 

Charge controllers: Five OutBack 
MX60, 60 A, MPPT, 70.4 Vmp input, 
24 VDC nominal output 

Inverters: Two Xantrex Series 2 
SW4024 inverters with Grid Tie 
Interfaces (GTIs), 4 KW each, 8 KW 
total, 24 VDC nominal input, 120/240 
VAC output 

System performance metering: Two 

form 12S AC KWH meters 

Wind System 

Turbine: Bergey Excel-S 

Rotor diameter: 23 ft. 

Rated energy output: 10,800 DC 
KWH/month at 12 mph (5.4 m/s) 

Tower: Bergey XLG37 guyed-lattice, 
120 feet 

Inverter: Xantrex GridTek 10, 10 KW, 
batteryless grid-tie, 240 VAC output 

System performance metering: AC 

KWH meter 



repeatedly exceed 28 mph, our Xantrex 
GridTek 10 inverter spends much of its 
time in standby mode. The turbine's 
power output increases as blade speed 
increases to 300 rpm — where the nominal 
maximum output of 10 KW is produced. 
In winds exceeding 28 mph, the turbine's 
rpm continues to slowly increase. At 
420 rpm (12.4 KW output), the inverter 
goes into standby mode to protect it 
from being overloaded. The inverter is 
designed to stay in standby for five 
minutes before turning on again. It will 
attempt to go back online regardless of 
how fast the blades are spinning. 

But if the inverter tries to reconnect 
when the turbine is spinning faster than 
460 rpm, it goes offline and stays that way 
until I notice it and do a manual reset. At 
times, there may be hours or days of lost 
production if I'm traveling or don't notice 
that the inverter is offline. This issue 
isn't unique to my unit: Testing at the 
National Renewable Energy Laboratory 
(NREL) documented this behavior back 
in 2002. Because I only recently added 
anemometers to the tower for measuring 
wind speed, I can't yet be certain how 
much energy production is lost due to 
this issue, but I estimate between 8% 
and 15%. 

Considering what was to follow, the 
inverter performance issue was minor. 
In February 2006, the wind generator 
threw a blade. This caused the turbine to 
vibrate so violently that it broke the pivot 
point connecting the turbine mount to the 
tower and the turbine fell — my $23,000 
wind generator was toast. Fortunately, 
the 1,100-pound turbine did not hit any 
guy wires on its way down — otherwise 
it could have taken down the tower with 




Mel and 
Charleen with 
the PV system's 
component wall. 




home power 125 /june & july 2008 



carbon free 




www.homepower.corn 








carbon free 




it A batch of defective blades was the cause of the failure. The 
system sat idle for almost six months until we received a new 
turbine in August 2006. The five-year warranty covered all the 
costs, and Bergey generously compensated us for the value of 
our lost electrical production — above and beyond the warranty 
terms. 

Harnessing the Sun 

In the spring of 2005, while we waited for our replacement 
wind turbine to arrive, construction of a new barn was 
underway. The barn faces toward true south with 1,000 square 
feet of roof area for our 10 KW PV array. We contracted 
Vermont Solar Engineering to design and install a grid-tied 
solar-electric system with about 60 KWH (at 80% depth of 
discharge) of battery backup for critical loads. An array of 80 
BP Solar 125-watt modules would feed five OutBack MX60 
charge controllers. But before we got very far into the project, 
we hit a few more regulatory stumbling blocks. 

NYSEG rules did not allow both a wind and a PV net- 
metered system on the same residential line. A call to NYSERDA 
confirmed this, but they said they were in the process of 
redrafting rules. NYSERDA contacted all power companies 
in New York and found that Niagara Mohawk would allow 
that combination. This gave the NYSERDA the leverage they 
needed to rule that all New York power companies must follow 
the policy allowed by Niagara Mohawk. 

That good news came with caveats, though. Due to the 
state's 10 KW cap on residential net-metered PV systems, 
NYSEG would not approve the use of more than 10 KW of 
rated inverter capacity. This restricted our inverter choices 
and ultimately resulted in a less-than-optimal system. To 
meet code, we ended up undersizing the inverter capacity 
to 8 KW and selecting older-model Xantrex SW inverters. 
It was a clear case of poor regulations dragging technology 
down with them, as a variety of more efficient battery-based 
inverters are currently on the market. 

Setting aside the regulatory walls we hit, our PV system 
has been operating without a serious glitch since November 
2006. We were pleased with the job Vermont Solar did on our 
installation, and they promptly corrected a couple of minor 
problems. 



Hitting Zero 

At long last, the day came to break ground for our new home. 
After nearly four years working through the regulatory and 
technical issues related to the power systems, building the 
house went surprisingly smooth, taking only about four 
months. By January 2008, we were moved into our new two- 
story home. The home features all the modern conveniences 
and amenities, as well as low-E windows, low-toxicity 
materials, and energy-efficient electric appliances. 

Although the up-front costs of our home's energy systems 
tacked on an extra 40% to the cost, the investment was well 
worth it. NYSERDA provided a 50% rebate on the installed 
cost of both systems, and we were able to take advantage of 
state and federal tax credits, which lowered our initial system 
costs significantly. In the long run, as utility rates continue 
to climb, the cost to operate the home will be far less than a 
conventional home that depends on fossil fuels. Over the past 
nine years, the price of electrical energy has been increasing 
at 3.7% annually and fuel oil has increased 14.6% per year. 
Taking this into account. I've calculated that our initial return 
on investment is about 5.4% per year and increases each year 
as the projected cost of energy goes up. This results in an 
estimated financial payback period of 10 to 11 years. 

While there were definitely some frustrating phases during 
the project, our solar-electric and wind systems have been 
operating smoothly for more than a year. I'm proud to say that 
we've reached an actual production of 19,000 KWH, and are 
offsetting more than 100% of the energy required to heat, cool, 
and power our new home, without relying on any fossil fuels 
or wood. Despite the problems, I wouldn't hesitate to tackle 
the project again. 

Access 

Mel Tyree (Mel.Tyree@ales.ualberta.ca) is a university professor who 
likes to build scientific equipment and tinker with electronics. As a 
public service, he compiles and posts information about small wind 
turbines on a University of Alberta Web page, called the Small Wind 
Information Exchange Program (www.ualberta.ca/~mtyree/SWIEP). 

Sustainable Energy Developments Inc. • 585-265-2384 • 
www.sed-net.com • Wind power equipment and installation 

Vermont Solar LLC • 800-286-1252 • www.vermontsolar.com • 
Solar-electric equipment and installation 

Small Wind Info: 

AWEA Small Wind Listserve • www.groups.yahoo.com/group/awea- 
smallwind/ 

SWIEP • www.ualberta.ca/~mtyree/SWIEP or http://tech. groups. 
yahoo.com/group/SWIEP • Consumer reporting group on wind 
systems 

System Components: 

Bergey • www.bergey.com • Wind turbine 

BP Solar • www.bpsolar.com • PV modules 

OutBack Power Systems • www.outbackpower.com • 

Charge controllers 

Surrette • www.surrette.com • Batteries 
UniRac • www.unirac.com • PV mounts 
Xantrex Technology Inc. • www.xantrex.com • Inverters 



home power 125 /june & july 2008 



Apricus Solar Hot Water Systems 




Perfect For 




V' Residential hot water 
Space heating 
S Hot tub heating 



V" Commercial heating 



The brightest way to capture the sun 



Distribution 
partners and 




installers still 
needed in many 

*> 



regions. 







■B 



The Apricus Advantage 

V Proven Designs 
S Long Warranty 

V' Customer Service 
S Reliability 
S Performance 

V Quality Installation 







North America Toll-free: 877-458-2634 
Visit: www.apricus.com 




POWER. DURABILITY. PERFORMANCE , 




Depend on the Power of Maroon for your most 
demanding off-grid and grid-tie backup applications: 

• Building the most trusted deep cycle flooded batteries in the world since 1 925 

•The next generation of Deep-Cycle Gel™ and AGM batteries for maintenance free 
cycling and backup applications 

Our signature deep cycle construction and durable Polyon™ casing are available through 
Trojan Battery's worldwide distribution network. 



Visit our booth #609 at SOLAR 2008 
May 3-8, 2008, San Diego, CA 



Trojan, 

BATTERY COMPANY# 

Clean energy for life m 




For live technical support, call 800-423-6569 or visit us at www.trojanbattery.com. 







Harvest the 



f£r of 



Season after season, 

the sun gives its light to the earth, 

allowing life to bloom. 



Every day a limitless crop of free, 
clean energy reaches our planet. 



Stiebel Eltron manufactures all the tools you 
need for a successful thermal solar harvest. 



And we've been doing so since 1976. 



From our highly efficient flat plate collectors and 
storage tanks to our complete line of mounting 
hardware, pump stations, controllers, and 
accessories, we have it all. 



Stiebel Eltron is your one stop solar shop. 

SOLKIT 2 includes: 



2 x SOL 25 PLUS 
Flat Plate Collectors 



Pump station with 
SOM 6 Controller 



SBB 300 Plus Storage Tank 



Because every installation is 
different, we have a full line of 
SOLKITS and mounting 
hardware kits available. All 
components and accessories are 
available for individual sale. 



Stiebel Eltron is the 
authorized distributor 
of Thermomax® 
vacuum tube collectors 
for New England. 



S TIEBEL ELTRON 

Simply the Best 

800 - 582-8423 

17 West Street 
West Hatfield, MA 01088 
info@stiebel-eltron-usa.com 

www.stiebel-eltron-usa.com 




Hydro-Electric Penstock Design 



by Jerry Ostermeier 



If you want to extract every last bit of energy from your 
microhydro system, three main components are critical 
to optimal performance — intakes, penstocks, and turbine 
selection. Intake options were covered in HP124, along with 
various methods of diverting water from the source. Here, 
we'll talk about best practices for penstocks, which channel 
the water from the intake to the microhydro turbine, building 
up pressure along the way. 

In many ways, the penstock (pipeline) is the most 
important part of your hydro-electric installation. It's the 
"engine" in your system. Trying to cut corners on this design 
element can cost you in performance. And poorly installed 
penstocks can give you trouble, instead of what you're really 
after — maximum energy generation. 

Pipe Types & Pressure Ratings 

Almost any type of pipe will work as a penstock, at least to 
some degree. The most common types are white polyvinyl 
chloride (PVC) and "poly pipe" (black polyethylene, PE; or 
high-density polyethylene, HDPE), which come in several 
pressure ratings. Common drainpipe is thin- walled and not 
rated for pressure. Though it can accommodate up to about 
30 feet of head if you are careful opening and closing valves, 
drainpipe is not normally a recommended choice. 




Intake and top section of penstock with standpipe vent. 



Standpipe 
or Vacuum Release Valve 



Weir & Intake: 

See HP124 




The rules are simple 
straight as possible, round sweeps, 
and steady elevation declines. 



Supports: 

Keep pipe run 
smooth over 
varied terrain 



home power 125 /june & july 2008 



hydro penstock 



In selecting pipe with the correct pressure rating, be sure 
to allow an extra 40% above the static water pressure in the 
pipe. For example, with 200 feet of head, the static pressure 
is about 87 pounds per square inch (psi). Multiply that by 1.4 
(140%) to reach the needed pipe pressure rating of 122 psi. 
To compute the static pressure for the proposed penstock (in 
psi), divide the total head (in feet) by 2.3. 

To save on penstock costs, a system can use pipes of 
increasingly higher pressure ratings as it gets closer to the 
bottom of the run, where pressure is highest. In that case, 
calculate the pipe pressure ratings for different total heads as 
you move down the pipeline. 

Some hydro installers will disagree, but my strong 
preference for penstocks is to use PVC pipe in 20-foot lengths 
with a bell end for gluing lengths together. Splices used 
for other pipe types are not reliable at high pressure or for 
unrestrained pipe movement. Thin-wall poly pipe comes in 
a long roll and can be easy to use, especially if your penstock 
has to weave through trees and over rocks to the turbine, and 
if you can complete the entire run without splices. Thick-wall 
poly pipe requires special butt-welding equipment. The welds 
will leave a bead on the inside of the pipe that will affect flow. 
In our area, the critters tend to like chewing on poly pipe, but 
in other parts of the country, they seem to have a taste for the 
white PVC. 

Aluminum pipe can be easy to get in agricultural areas 
but generally should only be used for pressures up to about 
125 psi. It should not be buried unless treated to deal with 
the acidity in soils. Steel will handle very high pressure but 
should also not be buried, since it will rust out over time. 
Common PE poly pipe and HDPE have pressure ratings 
around 80 psi. They are available at even higher pressure 
ratings but can be hard to get in larger sizes. 

Dealing with Losses 

Aluminum, steel, and poly pipe have comparatively high 
friction loss (resistance to flow), so it is important to factor this 
loss into sizing — which can play a part in system cost. As with 
different types of electrical wire, every pipe type has different 
resistance to flow based on the roughness of the walls. Also 
like wire, the diameter of the pipe determines the resistance 
to flow and how much flow the penstock can handle. In 
very high-head situations, steel pipe might be the only pipe 
capable of handling the high pressures. 

Pipe friction-loss tables for each pipe material will tell 
you how much flow a particular pipe size can handle. Then, 
by comparing prices, you can determine if changing pipe 



Round 

the 



Bad: 90° elbow; 
lots of friction loss 




Good: Multiple 22.5° 
sweeps; far less 
friction loss 



Pipe lengths: At least 
three times pipe 
diameter 



diameter or material type is worthwhile. Steel and aluminum 
pipes generally have double or more the resistance of PVC, 
and the larger sizes tend to make it prohibitively expensive 
for use in small systems. 

Friction-loss tables are commonly used for hydro penstock 
sizing (visit www.homepower.com/penstocktables), but 
precise friction-loss calculations can become complicated 
because they deal with velocity, pressure rise, critical time, 
and pressure wave velocity — frankly, it can become a physics 
exercise. But more simplified pipe sizing " rules" can address 
all the factors adequately. The following rules are for typical 
PVC schedule-40 pipe with runs of 300 to 1,200 feet. Short, 



Choose your pipe type based on head, 
flow, run length, and your budget. 





hydro penstock 





straight pipe runs can exceed these max flow rates a little — 
longer pipe runs need to be reduced. 

• Up to 7 gpm can use 1-in. pipe (300 ft. of static head or 
higher) 

• Up to 15 gpm can use 1.25-in. pipe (250 ft. of static head or 
higher) 

• Up to 25 gpm can use 1.5-in. pipe (200 ft. of static head or 
higher) 

• Up to 45 gpm can use 2-in. pipe (any head) 

• Up to 75 gpm can use 2.5-in. pipe (any head) 

• Up to 110 gpm can use 3-in. pipe (any head) 

• Up to 190 gpm can use 4-in. pipe (any head) 

• Up to 300 gpm can use 5-in. pipe (any head) 

• Up to 430 gpm can use 6-in. pipe (any head) 

The "rules" list is based on rounded estimates. If you are 
pushing the envelope within a pipe size, it is usually better to 
go bigger. This strategy will almost always improve system 
performance. The same holds true for long pipe runs. Bigger 
pipe will make more power available to your hydro plant at 
the bottom end of the penstock. 



Web Link: For more information on determining 
pipe and fitting friction loss, go to www.homepower. 
com/penstocktables 

Penstock Protection 

Poly pipe is well known for being chewed on by rats, 
raccoons, and bear, to name just a few — but PVC has been 
attacked too. On the other hand, poly pipe can sometimes be 
better than harder-shelled pipe types because it is relatively 
freeze-tolerant and can be a little tougher for laying over 
treacherous terrain. Buried pipe offers more protection from 
toothsome critters, freezing, and falling trees, and more 
stability to handle pipeline movement. 

If you are burying the penstock, the recommended trench 
depth is 2 feet for pipe up to 4 inches in diameter. Bury larger 
pipe at least 2.5 to 3 feet deep. Also be sure to check average 
frost depth in your area. Although moving water generally 
won't freeze in most climates, snafus — such as blocked 
nozzles in the turbine — can stop the flow of water and lead to 
freezing during a cold snap. 

The trench bed should be free of sharp rocks that can 
damage the pipe. A layer of sand or pea gravel under the 
pipe works great. The trench should not curve beyond the 



Supporting the penstock with brackets and cables helps 
keep the run smooth and prevents pipe movement. 




home power 125 /june & july 2008 



hydro penstock 

Valves St Vents: Microhydro Relief 



Placing a valve between the intake's pipe and the main penstock 
can be quite handy when you need to shut down a hydro system 
for maintenance or freezing weather. Any type of valve, other 
than a plastic slide-gate, will work. I usually place a union close- 
coupled just below the gate valve, so I can clear pebbles or other 
debris that might accumulate in the cavity at the bottom of the 
valve and prevent the valve from closing completely. 

Sometimes, instead of adding a valve, the connector between 
the penstock and the intake pipe, such as a rubber compression 
union, can be removed to keep water out of a penstock. This is 
not only a hassle and slower than a valve but also problematic 
if the pipeline has to be shut down in a hurry. Some systems 
may use a rubber hose to connect the two pipes. In this case, it 
is important to make sure that the hose is suction-rated and has 
wire coil molded into the rubber to prevent collapse. A screw- 
apart union or a compression splice can also work to keep water 
out of the penstock. 

At the turbine, consider using a gate valve for the main shutoff — 
especially for high-head systems. Compared to a ball valve, they 
operate slower, reducing the risk of water hammer — an effect 
caused by stopping a flow of water too quickly. There's a lot 
of kinetic energy in water flowing down a pipe, and gradually 
slowing the flow to a stop will avoid the high pressures that can 
break or weaken a pipe and its joints. A ball or vane valve can be 
a better choice on lower-head applications because they create 
less turbulence at their typically higher-flow rates. Regardless of 
your system type, this rule is paramount: Be careful to shut the 
main valve at the turbine slowly to avoid water hammer. 

Venting also should be included in any design, especially in 
a system that has an upper shutoff valve, because there is a 
chance that the intake screen could become blocked enough to 
collapse the penstock. The down-pipe movement of water can 
create tremendous suction in the pipe if its flow is stopped from 
above. At 200 feet of head, a pipe has greater risk of collapsing 
from suction than breaking from water hammer when a turbine 
shutoff valve is suddenly closed. 



A manual valve works as an air-vacuum release. 





Top-of-penstock components. 



The diagram above shows an automatic air-vacuum-operated 
release valve. If a vacuum occurs, the valve lets the penstock 
drain without damage. Penstocks 4 inches and smaller should 
use a V 2 -inch or larger valve. Larger pipe should have a valve 
sized no less than one-sixteenth the diameter of the penstock. 

Another method for suction relief uses a standpipe, which must 
be placed below the valve to the penstock and extend above the 
maximum level of the water source at the diversion. This keeps 
the penstock open to the atmosphere above the water level. Be 
sure to place the standpipe far enough down the penstock so that 
the system will have enough suction to draw through the intake 
instead of sucking air down the standpipe. 

A standpipe can also help purge from the penstock any air 
bubbles mixed in with the water that result from turbulence 
in the intake area. Spring-loaded and manual vents are also 
available. Avoid the floating ball type because they tend to open 
when they shouldn't, sucking air at higher-flow rates or in the 
event of partially obstructed intake filters. Air trapped at any 
high points in the pipeline can slow or stop water, decreasing or 
even stopping turbine output. At low heads (32 feet or less), this 
is not usually a problem, but air in the penstock can also lead 
to premature bearing failure in the turbine, or even damage the 
runner, when an on-off repeated pulse set up by water-airspace 
repetitions acts like little hammer blows hitting the runner. The 
higher the head and the bigger the airspace, the greater the blow 
to the turbine. 

Another air-removal method is to use permanently installed 
manual valves to bleed the air from the high spots when the 
penstock is full but not flowing. Some hydro system owners will 
simply thread a screw into the penstock at the high points, and 
occasionally back the screw out to bleed any accumulated air. 

The bottom of the system should always include a drain valve for 
draining all piping or bypassing the hydro plant. In cold climates, 
the unburied end of the penstock, valves, and hydro manifold 
are susceptible to freeze damage if the flow is stopped, so it is 
critical to keep the drains or bypass open if freezing weather is 
imminent. This applies to all nozzles on the hydro — not just the 
ones that are currently "on." Re-jet the nozzles if necessary to be 
able to open them all. If you can't, it is better to shut the whole 
thing down and drain everything. Not paying attention to this can 
cost you several hundred dollars in freeze damage. 



www.homepower.corn 




hydro penstock 




A penstock, heavy with water, should be anchored at the 
turbine to keep from moving downhill. How much anchoring 
is necessary is calculated in the same manner as any other thrust 
blocking. In areas with very steep terrain, there may be no way to 
apply thrust blocking in the normal manner. Instead, the pipe can 
be anchored with wire rope by attaching one end to the hillside's 
rocks or trees and the other end to the pipe, and then, using 
tumbuckles for adjustment. 

Lower Penstock & Hydro Connection 

Connecting the turbine to the penstock usually involves 
correcting the angle of the downhill pipe run to match the 
turbine's angle, which is usually zero. You can change the 
angle with a king nipple (similar to a hose barb) and a short, 
high-pressure piece of rubber hose, or you can use two 
22.5-degree elbows that can make any correction up to 45 
degrees. Correction may be unnecessary for hydro turbines 
that have a gang manifold at the end of the penstock or 
use valves and hoses to feed the individual nozzles. Some 
manifolds are hard-plumbed, and will likely need an angle 
correction where they meet the penstock. A cleanout valve at 
the end of the manifold may also be helpful for draining or 
flushing leaves and trapped sediment. 

The most visually impressive installations have the pipe 
exiting the ground at a 22.5-degree or 45-degree angle inside 
a shed or protected area that houses the hydro turbine. If you 
keep your turbine out of the weather, it will last longer and 
need less service, especially the wound-field models. 

Hydro Mounting & Tail Race 

Since most turbines are meant to discharge water out the 
bottom, it's important to design your system so the "waste" 
water can move away freely. In constructing a turbine mount, 
be sure that the cutout is not smaller than the turbine's tail- 
water opening. A cutout that is too small will deflect water 
back into the runner and reduce the system's performance. 

At the Turbine 



recommendations for the particular pipe being laid in it, or else 
the pipe could break or distort to the point of flow restriction. 

Water weight and normal vibrations from water moving 
through the pipe can cause the pipes to move. Where a 
change in flow direction occurs, like at an elbow, powerful 
forces can break or separate connections. "Thrust blocking" 
at the bends in the system prevents that pipe movement. 
Blocking is usually unnecessary for 3-inch or smaller pipe 
that is buried in most soils. The illustration above shows 
recommended thrust blocks for different bends commonly 
found in penstocks. For pipes up to 5 inches, it is prudent 
to dig a little deeper at the critical points, build a makeshift 
form, and pour concrete over the entire corner. Though the 
concrete does a good job at keeping the pipe in place, it also 
can make pipe replacement or repairs difficult later on. For 
larger pipe and high-flow situations, the size of the thrust 
block must be calculated precisely, (see "Calculating Thrust- 
Block Size" sidebar). 



From Penstock 




home power 125 /June & july 2008 



hydro penstock 



Calculating Thrust-Block Size 



Preventing pipe thrust from harming a penstock is critical to 
a successful hydro installation. Here is a sample thrust-block 
design calculation for a 45-degree bend in the penstock. This 
case assumes that a 4-inch pipe under 87 psi of pressure is 
buried in medium, clay-type soil. 

Determine pipeline thrust. From the "Pipe Fitting Thrust" table, 
the factor is 12.4 Ibs./psi for a 4-inch pipe and a 45° elbow. 

Calculate the total thrust at the fitting. 12.4 Ibs./psi x 87 psi 
working pressure = 1,078.8 lbs. of thrust 

Determine soil load strength. From the "Soil Load Strength" 
table, the soil load strength is 2,000 lbs. per sq. ft. 

Calculate the size of the thrust block. 1,078.8 lbs. 2,000 lbs. 
per sq. ft. = 0.54 sq. ft. of thrust-block surface area 

The computation means that 0.54 square feet of blocking is 
necessary to hold the bend against the medium clay-type soil. 
Concrete is usually poured over the pipe fitting, filling the area 
against the undisturbed trench sides for thrust blocking. 

For unburied pipe or pipe in soft soils with little resistance to 
movement, thrust blocking needs to rely on mass instead of the 
area resting against trench wall. Here is an example calculation 
of thrust block weight for a 6-inch pipe at 139 psi with 8 degrees 
of deflection: 

Determine the thrust factor. From the "Side Thrust" table, 

6-inch pipe has 61 lbs. of thrust per 100 psi per degree of 
deflection. 

Calculate the amount of thrust. 0.61 Ibs./psi x 8° x 139 psi = 678 lbs. 

This means that there needs to be 678 pounds of mass (usually 
poured concrete) to keep this penstock from moving at the 
bend. 



A chunk of concrete, cast in place, acts as a thrust block for a 
small change in direction of this penstock. 




Pipe Fitting Thrust 



Thrust (Lbs./psi) 



Pipe 

Size (In.) 


Tee 


90° 

Elbow 


45° 

Elbow 


22.5° 

Elbow 


1.5 


2.94 


4.16 


2.25 


1.15 


2.0 


4.56 


6.45 


3.50 


1.80 


2.5 


6.65 


9.40 


5.10 


2.60 


3.0 


9.80 


13.90 


7.50 


3.80 


4.0 


16.20 


23.00 


12.40 


6.30 


5.0 


24.70 


35.00 


19.00 


9.70 


6.0 


35.00 


49.00 


27.00 


14.00 


8.0 


59.00 


84.00 


45.00 


23.00 


10.0 


92.00 


130.00 


70.00 


36.00 


12.0 


129.00 


182.00 


99.00 


50.00 



Soil Load Strength 



Soil Type 


Safe Bearing Load (Lbs./Sq. Ft.) 


Shale 


10,000 


Cemented sand & gravel; 


4,000 


hard to pick 


Good mix compact soil 


3,000 


Clay — medium 


2,000 


Clay — soft 


1,000 


Side Thrust 




Pipe Size (In.) 


Thrust Factor* 


1.5 


5 


2.0 


8 


2.5 


12 


3.0 


17 


4.0 


28 


5.0 


43 


6.0 


61 


8.0 


103 


10.0 


160 


12.0 


225 



*Lbs. per 100 psi per degree deflection 



Although the most common mount is a simple, 2- by 4-foot 
plywood, structure, built close to the water source, the most 
durable mounting platforms are sturdy plates on permanent 
concrete structures with the tail or waste water exiting the 
bottom or side, either into a wide opening or a drain pipe. The 
drainpipe needs to be at least twice the diameter of the supply 
pipe, with a reasonably steep downward slope. An air vent in 
the tailbox will help prevent the tail water from sucking on 
the water running through the hydro, creating a power loss 
on an impulse turbine. The vent also removes pressure so that 
water won't find its way into the front bearing, which can 
lead to a bearing failure in some hydro turbines. 



www.homepower.corn 



61 



Courtesy www.microhydropower.com 



hydro penstock 

Another popular hydro mounting method uses a modified 
55-gallon metal drum, with the turbine fastened to the drum 
top with bolts. The bottom third of the drum is secured into 
the creek bank with concrete or by loading the drum with 
rocks. The middle third has a hole drilled out, which allows 
water discharge. These drums will usually last about 10 to 15 
years before they rust out. 

Alternatively, an up-ended culvert pipe that is 24 inches 
or larger can be used, though fabricating a top will be more 
difficult. My preferred top is a high-density polyethylene 
sheet at least V2-inch thick. This special-order item is more 
expensive, yet longer lasting, than plywood. 

Mounts can have more elaborate masonry spillways or 
even drains that feed to a decorative water feature in the 
yard. Other times, the tail water can be used for a secondary 
purpose, such as filling a pond or irrigating a garden. Let 
your imagination be your guide, but remember that once you 
have extracted the energy for making electricity, the water 
will not be pressurized for other uses and gravity needs to 
take the water away freely. 

The final consideration for hydro mounting is protection 
for electrical portions of the control panel. Though rain 
needs to be kept out, the unit should not be so well sealed 
that condensation becomes a problem. A roofed, three- 
walled structure for the turbine works great. One side is 
left open for easy access to the hydro plant. Although most 
permanent-magnet turbines are built for outdoor operation, 
they will last longer if protected from the elements. In terms 
of human resilience — an all-important factor to enable turbine 
maintenance — having a shelter makes repairs, flushing the 
penstock, and cleaning the turbine jets much more tolerable. 

The components at the bottom: Thrust block, coupler, pressure 
gauge, cleanout valve, nozzle valves, turbine, and tailrace. 






Tailrace Hole: 

Cut from middle 
section 



Ballast: 

Rocks in bottom 



55-Gallon Drum 



Best Penstock Practices 

For penstocks, the rules are simple — straight-as-possible, 
round sweeps, and steady elevation declines. Unfortunately, 
that's usually easier said than done. Often times, site constraints 
make it necessary to break or bend the rules. You should do 
what you have to do, but know that your system will be more 
vulnerable to performance and maintenance issues. Any low 
spots in the pipeline, for example, could become sediment 
traps that will occasionally need to be blown out by opening 
the pipe at the bottom and letting it run full volume. High 
spots in the penstock will create air pockets that will need to 
be bled. Finally, any bend in the pipeline will mean greater 
resistance to flow and reduce the energy available. 

Include a pressure gauge in the pipe on the uphill side of 
the lower shutoff valve to help diagnose problems. A higher- 
than-normal reading usually indicates a plugged jet. A lower- 
than-normal reading can mean that the pipe or filter screen 
is plugged, or that there is not enough water available to the 
penstock. A pulsating gauge indicates turbulence, usually 
caused by running a higher flow rate than the penstock is 
designed for, which can result from installation errors, such 
as too many bends or an uphill run somewhere. 

Select the right pipe, anchor it well, and keep it straight 
and simple. Follow these rules, and the penstock "engine" 
will serve you and your turbine well — and get the most 
energy out of your hydro system. And be sure to check out 
the next installment, where we'll take a look at the electrical 
and wiring aspects of your hydro system. 

Access 

Jerry Ostermeier (altpower@grantspass.com) owns Alternative 
Power & Machine in Grants Pass, Oregon (541-476-8916 • www. 
apmhydro.com). He has been designing and installing microhydro 
and off-grid power systems since 1979. He also manufactures a user- 
friendly residential-scale microhydro turbine. 



home power 125 /june & july 2008 




We DESIGN, MANUFACTURE and DELIVER the 

sun’s unlimited energy to your everyday life 



We are an internationally recognized manufacturer of high quality mono 
and multicrystalline PV modules with locations around the globe. We are 
one of the few PV manufacturers that has developed a vertically integrated 
business model from the production of crystalline ingots, wafers and cells to 
the assembly of high quality modules. Producing each step of the value 
chain in-house helps to ensure that we deliver high quality products to our 
customers for clean and efficient residential, commercial and utility-scale 
solar solutions. 

TRINA SOLAR. CELEBRATING TEN YEARS OF SUCCESS IN SOLAR, THANKS TO YOU! 

Visit us: InterSolar North America, San Francisco, CA, July 15-17, 2008 (Booth #: 9112) 



Trmasolar 

www.trinasolar.com 

usa@trinasolar.com 

NYSE:TSL 



A 

B 



A « 




www.homepower.com 




rebuilt & fully loaded for 2008 



F or more than twenty years, Home Power magazine has inspired and 
educated readers with practical, reliable information about renewable 
energy and sustainable living technologies. Homepower.com now enables 
you to conveniently browse, download, and print the best of that content 
online, anytime, for just $24.95 (one year). 



Membership to homepower.com includes: 



► Access to a growing pool of more than 1,300 feature articles, columns, Q&As, and more 

► Advanced search and filtering functionality to quickly find what you’re looking for 

► Access to three years of complete back issues in PDF, exactly as published 

► E-mail notification when each new issue of Home Power is available for you to download 

► The option to add a subscription to Home Power’s print edition for just $9.95 per year! 



Already a subscriber to the print edition of Home Power ? 
Add an online membership for just $9.95 per year. 




Visit homepower.com to explore what’s new and activate your membership today: 

www, homepower, com / j om 









DC Power\ 

Systems^ 



Proud Distributor of Sharp Solar Energy Products 




fr 

£ 






!!-; 

to 

m 




V ! 1 

A? J 

Vi Jr 1 


'it:: \ 


sen 




in 

Efl j 














Sharp Solar Racking System (SRS): 

• Integrated grounding • Shared rail design 

• No protruding screws • Ultra low profile 

• No cutting, no drilling • Covered rails 

• Fast, simple installation • Economical 

To order the new Sharp SRS System 
call us at 800-967-6917 

DC Power Systems 

Full spectrum of solar energy products, in-house tech support, product training, 
financing solutions and unparalleled product availability 

Become a DC Power Systems dealer today 

103 W. North St. Healdsburg, CA 95448 phone 800-967-6917 fax 707-433-5698 
info@dcpower-systems.com www.dcpower-systems.com 






String Theory 






PV Array 
Voltage Calculations 



by Ryan Mayfield 



A decade or so ago, most PVs were designed with 
battery charging in mind. Module open-circuit and 
maximum power voltages fit into simple 12- volt 
nominal building blocks — one or more modules wired in 
parallel provided ideal voltage for charging a 12 V battery 
bank. Strings of two modules wired in series charged 24 V 
battery banks, and "high" voltage systems had four modules 
in series and operated at 48 V nominal. But as inverter 
and charge controller designs have evolved, the concept of 
designing systems in 12 V increments has faded. 

Today, grid-direct battery less inverters are designed for 
up to 600 volts open circuit (Voc). Several brands of maximum 
power point tracking (MPPT) charge controllers are able to 
charge a lower-voltage battery bank (12 to 48 V nominal) 
from higher-voltage arrays with open-circuit voltages of 
approximately 150 Voc. Even module design voltages have 




The Fronius IG 5100 
inverter has an 
operating voltage 
range between 150 
and 450 VDC, and 
a maximum input 
voltage of 500 Voc. 



The Fronius string- 
sizing calculator 
is available 
online and for 
downloading. 



deviated from the simple 12 V building-block approach. First, 
24 V nominal modules hit the market, and now many modules 
operate at voltages either above or below 24 VDC nominal. In 
fact, in most systems, the concept of PV array nominal voltage 
has been left by the wayside. Open-circuit voltage (Voc) and 
maximum power voltage (Vmp) are now the basis of PV array 
design. 




home power 125 /June & july 2008 





String Sizing Considerations 

A number of variables affect PV array 
voltage and performance. Module- 
specific operating characteristics, the 
number of modules in series, cell 
temperature, mount type, inverter or 
charge controller specifications, and 
the coldest historical temperature at 
your site all come into play. Most, 
if not all, high-voltage-string inverter 
manufacturers have online calculators 
to help system designers determine 
the maximum, minimum, and the ideal 
number of modules per series string 
for their equipment. Similar calculators 
have yet to be developed by all MPPT 
charge controller manufacturers, so 
system designers need to run their 
own calculations to determine an 
array's acceptable voltage range. 
While string-sizing calculators remove 
much of the math from system design, 
understanding how the calculations are 
made will help you better understand 
how a PV array functions day to day 
and season to season. 



string theory 

IV Curve per Cell Temperature 




HighTemp. (63°C; 145°F) STC (25°C; 77°F) Low Temp. (-22°C; -8°F) 



Temperature Effects & Array Voltage 

A PV module's voltage is directly affected by its operating 
temperature. As module temperature increases, voltage 
decreases. PV module manufacturers rate a module's open- 
circuit and maximum power voltages at a standard test 
condition (STC) of 25°C (about 77° F). As module temperature 
rises above 25°C, the voltage drops. Conversely, if the 
module's temperature drops below 25°C, the module's 
operating voltage will be greater than its rating at STC. 

Because temperature has a significant effect on module 
output, PV manufacturers specify a module's temperature 
coefficient, which is represented as a percentage of voltage 
loss per 1°C above 25°C. A common temperature coefficient 



value for crystalline PV modules is -0.38% per degree Celsius; 
so for every 1°C above 25°C, the module temporarily loses 
0.38% of its voltage. And for every 1°C below 25°C, the 
module voltage will increase by 0.38%. 

Another approach to specifying the effect of changing 
module temperature is a voltage correction value — the 
number of volts per degree Celsius that the module will 
lose as its temperature rises above the 25°C reference point. 
For example, a crystalline module with a maximum power 
voltage of 34.8 volts might have a temperature correction 
factor of approximately -0.144 Voc per degree Celsius. These 
figures are provided on the module's specification sheets. 




The Kaco 3601xi 
inverter has an 
operating voltage 
range between 125 
and 300 VDC, and 
a maximum input 
voltage of 400 Voc. 



The Kaco string- 
sizing calculator 
is one part of the 
system design 
software available 
for download. 




www. homepower . com 





string theory 




It may not sound like much, but when the temperature 
values are applied, the combined effect can be substantial. 
For example, on a sunny summer day, module temperatures 
in a parallel-to-the-roof array installation will typically be 
about 35°C (63°F) above ambient temperature. If the module's 
temperature coefficient was -0.38%, for every degree Celsius 
in temperature rise array voltage will be reduced by this 
percentage. In this case, if the ambient temperature was 25°C 
(77° F), the module temperature would be approximately 60°C 
(140°F), and the actual array voltage would be about 13.3% 
below its rated value at STC. 

Sizing to the Voltage Window 

The power processing equipment connected to a PV array also 
has an allowable voltage range. This is true of high-voltage 
string inverters, battery-based MPPT charge controllers, and, 
less commonly, DC loads, such as well pumps that are 
directly connected to PV modules. 



The SMA online 

string-sizing 

calculator. 



The SMA Sunny Boy 
SB7000US inverter 
has an operating 
voltage range 
between 250 and 
480 VDC, and a 
maximum input 
voltage of 600 Voc. 




These components have both maximum Voc and minimum 
Vmp requirements. Together, these specifications represent the 
"voltage window" within which the components can operate. 
For example, a high-voltage grid-direct inverter might have a 
maximum Voc rating of 600 volts, and an operating voltage 
range or window between 240 and 550 VDC. 

In many cases, inverters and charge controllers can be 
damaged if the array produces voltage greater than the 
maximum value of the equipment, which can happen in 
cold, sunny weather if the design voltage is too close to the 
maximum. In turn, if the array voltage drops below the 
minimum value due to elevated temperatures, inverter or 
controller power production will stop until the array cools and 
the voltage rises. Because of this, PV system designers need to 
account for both extremes of the voltage window to ensure that 
the PV system will perform in the full range of conditions. 

For a particular piece of equipment, voltage correction 
factors must be applied to the array's assumed operating 
temperatures for the system's site. This information is one 
piece of the puzzle that will help determine the appropriate 
number of modules allowed in a series string. 

It all boils down to choosing a string size that meets three 
very important parameters while trying to optimize a few 
more. You must satisfy a voltage window that, on the high 
end, is limited by the maximum open-circuit voltage that 
the inverter or controller can handle before you harm its 
electronics. On the low end, there are two limiting factors — 
the minimum MPPT voltage that the inverter can operate 
at and the minimum start-up voltage the inverter needs to 
have. If the maximum Voc and minimum Vmp values are 
correctly calculated and the array designed to these specs, the 
minimum start-up voltage will always be met. 

Once you have satisfied these requirements, you'll still need 
to determine the appropriate array wattage to ensure you are 



home power 125 /june & july 2008 




string theory 



using the inverter or controller efficiently. Oversizing an array's 
wattage typically won't damage inverters or controllers, but a 
portion of the array's output will be dumped (wasted) as heat, 
and elevated operating temperatures may lead to shortening 
the operational life of the equipment. When sizing the array, 
you'll also have to stay within the inverter or controller's 
amperage limit, and size transmission wiring to keep voltage 
drop to a minimum. Finally, because PV module output is 
inherently temperature dependent, all of these parameters 
are moving targets, with cold and hot weather performance 
varying greatly, and array output current changing throughout 
the day as irradiance levels fluctuate. 

Maximum Modules in Series 

PV modules reach open-circuit voltage with very little irradiance 
striking them, approximately 200 watts per square meter. This 
can often occur within half an hour of sunrise, before the sun 
has the opportunity to warm the modules. And although the 
array will be at Voc and not producing any power, that voltage 
will be applied to whatever component it is connected to. 

To determine the maximum number of modules allowable 
in series for a given piece of equipment, you'll need to 
determine array Voc at the coldest historical temperature 
where the array will be installed (see www.weather.com/ 
common /home/ climatology.html). You may need to adjust 
this value somewhat for your microclimate and elevation. 
The temperature used in this calculation is most often the 
record low temperature at the array location. To determine 
the adjusted open-circuit voltage (Vadj) for the PV module, 
use the following equation: 

Vadj = Voc x {1 + [(Tcell - Tstc) x temperature coefficient]} 

Where: 

Vadj is the adjusted voltage for the module; 

Voc is the STC open-circuit value for the module; 

Tcell is the module's cell temperature in degrees Celsius 
(the cell temperature in this situation will be the same as 
the coldest historical ambient temperature at the site); 

Tstc is the STC temperature value for the module, 
generally 25 °C; and 

Temperature coefficient is the percentage loss of voltage 
specified for the module. 

To determine the maximum number of modules allowed 
for a piece of equipment, the adjusted voltage must be divided 
into the equipment's given maximum voltage (Vmax). Round 
down to the next whole number to ensure the array's voltage 
will not exceed the maximum value. 

Minimum Modules Needed Per String 

After calculating the maximum number of modules allowable 
per string, verify the minimum number of modules needed. The 
array needs to be sized so that when the system is operating at 
high temperatures, the array voltage remains above the minimum 
voltage-window threshold to ensure continued operation. To do 
this, you'll need to determine the array voltage (Vmp) based on its 
typical operating temperature during the hot summer months. 



Example String-Sizing 
Calculations 

Location & Climate 

Location: Corvallis, OR 
Record low: -22°C (-7°F) 

Average low: 1°C (34°F) 

Average high: 28°C (82°F) 

Record high: 42°C (108°F) 

Photovoltaics 

Module: SolarWorld 175 W 
Voc: 44.4 V 
Vmp: 35.8 V 

Temperature coefficient: -0.33%/°C 
Mount type: Parallel-to-roof mount 

(4 in. from roof surface to back of module) 

Equipment 

Inverter: PV Powered 5200 
Maximum Voc: 500 VDC 
Minimum Vmp: 240 VDC 

Calculations 

Step 1. Calculate the adjusted voltage for low 
temperatures. 

Vadj = 44.4 V x {1 + [(-22°C - 25°C) x -0.33%/°C]} 

Vadj = 51.3 V 

Determine the maximum number of these modules in 
series for this inverter at this location: 

Maximum number per string: 

Component's max. Voc Vadj for low temperatures 

500 VDC - 51.3 V = 9.7 modules 

Round down to the next whole number — in this case, 
nine modules is the maximum number in series. 

Step 2. Calculate the adjusted voltage for high 
temperatures. 

Vadj = 35.8 V x {1 + [(28°C + 35°C - 25°C) x -0.33%/°C]} 

(Note the additional temperature — 35°C — due to the 
racking method.) 

Vadj = 31.3 V 

Determine the minimum number of these modules in 
series for this inverter at this location: 

Minimum number per string: 

Component's min. Vmp Vadj for high temperatures 

240 VDC -r 31.3 V = 7.7 

Round up to the next whole number — in this case, 
eight modules is the minimum number in series. 

Comparing these calculations to those for other equipment 
will determine if you may be better off with a different 
combination of equipment. The minimum value calculated 
should always be carefully considered and is rarely the 
best choice. In this example, if strings of eight modules 
are used, the resulting Vmp on an average day will only 
be 250.4 — precariously close to the low value (240 VDC) of 
the sample inverter's operating window. 



www.homepower.corn 




string theory 







The Xantrex GT5.0 
inverter has an 
operating voltage 
range between 240 
and 550 VDC, and 
a maximum input 
voltage of 600 Voc. 



The Xantrex 
online string- 
sizing calculator. 



Hacking Correction Figures 

Two things — array mounts and operating temperatures — are 
important in evaluating the array's operating voltage. The type 
of module mounting used influences heat dissipation — some 
methods allow for better airflow than others (see "Rack & 
Stack" in HP123). And although there are methods to estimate 
the module's operating temperature based on mounting 
method and irradiance, it is common to use industry-accepted 
factors based solely on mounting methods. These values are 
added to the ambient temperature to estimate the array's 
operating temperature. 

The racking correction temperatures are applied to the 
highest average ambient temperature at the array's location: 

• Parallel to roof (<6 in. standoff): +35°C 

• Rack-type mount (>6 in. standoff): +30°C 

• Top-of-pole mount: +25°C 

The highest temperature used is generally the average 
high temperature during the summer months, although some 
designers prefer to use the annual record high temperature for 
this calculation. Using the annual record high temperature for 
the calculation is a more conservative approach that ensures 
that the array will operate in all conditions it is subjected to 
without dropping below the inverter's voltage window. 

After the module's voltage is corrected for maximum 
temperature, this value is divided into the component's 
minimum voltage window. The result is a fractional value 
that must be rounded up to the next highest whole number, 
since at times the array will be operating at temperatures 
higher than the average value used. 

When determining the minimum number of modules in 
series, designers need to be careful not to design a system 
that will normally operate at the very bottom of the voltage 
window. An array's voltage that consistently drops to or 
near a component's minimum window on "average" days 
increases the possibility of reduced energy output on days 
that exceed the average temperature. And, while PV modules 



C K * — - -»» -■ ■« ■ ■ i - 1 




XBntTEX 




are built to last, some degradation occurs over time. This is 
primarily due to moisture ingress that gradually corrodes 
a module's internal electrical connections, creating higher 
resistance that, in turn, results in lower operating voltages. 
In extreme cases, this voltage degradation could amount 
to as much a 1% annual drop in module voltage. So you'll 
also need to account for this over the array's lifetime. Given 
these considerations, designing string sizes well above the 
minimum acceptable voltage level is sound system design. 

Access 

Ryan Mayfield (ryan@renewableassociates.com) has a degree in 
environmental engineering from Humboldt State University and lives in 
Corvallis, Oregon. He teaches PV classes at Lane Community College 
and Solar Energy International, and is a principal at Renewable Energy 
Associates, a firm focusing on PV system design, implementation, 
commissioning, and industry-related training. He holds a Renewable 
Energy Technician license in Oregon. 

Online String Calculators: 

Fronius • www.fronius-usa.com 

Kaco • www.kacosolar.com 
PV Powered • www.pvpowered.com 
SMA America • www.sma-america.com 
Solectria • www.solren.com (charts only) 

Xantrex • www.xantrex.com 



home power 125 /june & july 2008 







RV Solar Packages 



Natural Light Solar Attic Vent/Fan 
10W&20W Modules 



alternative energy store 

www.altenergystore.com 

Shop online 24/7 or call now (M-F, 9AM-7PM EST) 
Toll-free: 1.877.878.4060 or Direct: +1.978.562.5858 



Learn about Renewable Energy 
with our new Webinars! 



Energy Basics • Solar Air Heating Basics • Solar Electricity Basics • More to come! 
Now available online at: http://learn.altenergystore.com. Sign up today! 
Remember to use code HP125 for an extra discount! 






Xantrex XW 

Inverter/Chargers 

Successor to the robust, 
well-regarded SW series. 

True sine wave, 120/240-volt 
AC, split-phase, inverter/char- 
ger that incorporates a DC to 
AC inverter, a battery charger, 
and an AC auto-transfer switch. 

starting at $2,599 



Southwest Windpower 

Air Breeze Wind Turbine 



Quieter, more efficient, and 
precision engineered to 
deliver more energy at lower 
wind speeds than any other 
wind generator in its class! 



starting at $557 




“Making renewable do-able” 

The Alternative Energy Store is 
the premiere retailer of renewable 
energy goods. We provide not only 
the expertise and the technical 
service the Do-It-Yourselfer needs, 
but also a place for learning & 
sharing with others who have 
the same passion. 

We make renewable do-able. 



Power your RV with the sun! 

Packaged systems in stock and ready to go. 
(Airstream not included!) 




starting at $139 



Sun-Mar 

Garden Composters 




Reduce your contribution 
to landfills AND produce 
beautiful compost for 
your garden! 

Made in the U.S.A.! Get 
'em while we’ve got 'em! 



starting at $288 



Apollo Solar 

T-80 MPPT Charge Controller 

Reduces the cost of your solar electric system 
dramatically by reducing the number of PV panels 
required, decreases your need for expensive 

I illl 1 , heavy gauge wiring, and gives you 

the freedom to grow to a large system 
as you can afford without buying 
another controller. Up to 35% more 
HII efficient than traditional solar charge 
controllers and you can upload 
charging data to a < 1*790 

PC or 

the ‘net. 



A simple and environmentally sensible solu- 
tion that can save you money! 
Powered completely by solar 
energy, these efficient 
units are installable by 
the do-it-yourselfer. 



starting at: $350 




We even 



Solar Panels 

Call today for updated pricing 
and availability on your favorite 
solar module brands! 

eveignew '2 KSDLtud 

t A tWV and many 
more! 



P3 International P4400 

Kill-A-Watt Power Meter 




Use the Kill-A-Watt Meter to 
discover how much energy 
your appliances and electronics 
are REALLY using and where 
you can start saving on your 
electricity bills! 



$33 



Great Prices • Friendly Service • FREE Online Educational Materials • NEW! Public Renewable Energy Training Workshops 




Puzzled? We’ve Got the Solution. 




A well designed renewable energy system is much more than a pile of hardware. 




We live on renewable energy, have 20 years of 
experience, and have established over 500 systems. 

Your best resource is a local pro. Tap into our network 
of qualified, competent Electron Connection associates 
across the country. 

Installing RE and looking for a competent distributor? 

Why talk to a sales technician when you can talk 
to an electrician? We know what works and how it 
works. We offer technical support, system design help, 
prompt shipment, fair pricing and NO BULL. Local 
referrals always. Electrical competence required. 



Bob-0 Schultze 
CA Electrical Lie # 
613554 
OR CCB Lie # 
149724 




Authorized Distributor Authorized Distributor 



■■wfcl 91 r LI r I i ■ 



Authorized Distributor 



WE PROVIDE COMPLETE SERVICE: 

• Solar 

• Wind 

• Micro-hydro 

• Water Pumping 

• Load Analysis 

• Local Site Survey 

• System Design & Installation 

• User Training & Tech Support 




Inert USB 




Authorized Distributor 



800.945.7587 toll free 

www.electronconnection.com online catalog 



P.O. Box 203, Hornbrook, CA 96044 U.S.A. • Voice/Fax: 530.475.3401 • E-mail: bob-o@electronconnection.com 















inter 

solar 



North America 




July 15-17, 2008 

i Francisco I California I Moscone G your place 



Intersolar North America will be the 
largest exhibition serving the entire solar 
technology supply chain in the United 
States. The event focuses on photovoltaic 
technologies, solar thermal technologies 
and solar architecture. 



5EMIGON 



ESS 

nfeture: SynPow^ Corporation- « - S _ 

www.intersolar.us 






mping Water 
ith Sunshine < 



by Erik Lensch 



One of the simplest and most 
economical uses of solar 
energy is for pumping water. 
With advancements in pumps 
and pump controllers, solar 
water-pumping systems have 
become fairly easyio install, 
operate, and maidfSilm^ / 



If you live beyond the reach of the grid, or have a remote 
pumping need like irrigation or livestock watering, 
a solar-electric pump system can be a solution that's 
reliable and sustainable. This article covers the basics of 
several types of PV-powered pumping systems, including 
array-direct, battery-based, and both pressure-tank and 
high-volume water storage. 

Solar Pump Types 

There are two basic types of solar water pumps — 
submersible and surface. In this article, we'll be looking 
primarily at submersible pumps used to deliver potable 
water for domestic use. A submersible pump is usually 
positioned in a well, although there are instances 
where a stream or pond is used as the source. Unlike 
surface pumps (installed above the source's water 
level) that draw water up from shallow sources like a 
pond, submersible pumps push water up to a holding 
tank or pressure tank. The right-sized submersible can 
pump water out of deep wells, up to 1,000 feet or more. 
Most models are durable and can tolerate water with 
relatively high levels of silt. 



Submersible pumps break down into three main 
categories — centrifugal, helical rotor, and diaphragm. 
Centrifugal pumps have an impeller that spins at high 
speeds, producing a high flow of water. Because the 
spinning rate is high, the flow rate is generally high. 
However, pressure, and therefore the amount of pumping 
height (head or lift) that can be attained, is usually lower 
than in other types of pumps. 

Higher lift can be achieved with helical rotor pumps 
(a type of "positive displacement" pump), which will also 
provide a flow rate great enough to meet most household 
demands. With these pumps, picture the water being sent 
out of the pump body in small "packets" that are pumped 
very quickly to provide a constant flow. An analogy that is 
sometimes used is that of a spiral staircase in a sealed shaft, 
with the staircase spinning around very quickly. Each "stair 
step" lifts water toward the top of the pump, then to the 
k pump outtake, and eventually out the top of the well. 
Since the water needs to be carried through the pump 
body, the result is a lower flow compared to centrifugal 
pumps. However, with its higher pressure, a helical rotor 
pump can deliver water against higher heads. 




home power 125 /June & July 2008 



pumping 



Depending on the model, submersible diaphragm pumps 
(another type of positive displacement pump) can pump up 
to about 5 gpm from shallow wells (under 100 feet), or lower 
volumes from well depths down to approximately 250 feet. 
A 4-inch well casing is typically required. Although these 
pumps are less expensive than centrifugal or helical pumps, 
they require significantly more maintenance. 

Different models of submersible pumps are designed to 
run on AC, DC, or both. To simplify wiring, off-grid residences 
with AC PV systems often rely on an AC submersible pump. 
It's important to note that most "AC" pumps actually 
utilize brushless DC motors. In this case, the pump contains 
electronics that allow it to be powered by a standard AC 
source like an inverter or the grid. The pump is just another 
AC load to be considered when sizing the system's battery 
bank, inverter, and charge sources. Many AC pumps will 
require two or more times the power (wattage) to start the 
pump than is needed when the pump is running, and the 
system's inverter needs to be able to handle this extra start- 
up load. The Grundfos SQ series of pumps is very popular in 
the off-grid world. These pumps have no start-up surge, and 
have a great reliability record in the field. 

But DC submersibles take more efficient advantage of 
battery-based PV systems compared to AC pumps. AC pumping 
includes DC-to-AC conversion losses: A PV array's direct 




A pump controller 
like this SunPumps 
PCB-180BT balances 
PV voltage and 
current to optimize 
pump performance 
throughout the day. 



current is stored in batteries before being converted to AC by the 
system's inverter, which in turn, powers the pump. Inefficiencies 
associated with the charging and discharging of batteries can 
account for losses of 5% to 10% or more, depending on the age 
and condition of the battery pack. And with an inverter average 
conversion efficiency of approximately 85%, an AC pump will 
require approximately 20% to 25% more PV energy to pump the 
same amount of water compared to a DC-direct pump. 



Submersible Pump Types 



A DC submersible diaphragm pump (middle) 
and a centrifugal pump (right), with controller 
(left), by SunPumps. 






www. homepower . com 





pumping 



Component Considerations 



For either PV-direct or battery-based solar water pumping, the 
following design practices can ensure a top-notch system that 
maximizes your investment. 

Site Right. For optimal performance, the array must be free 
of shading during the day and must be facing as close to 
true south as possible. For most residential water-pumping 
systems, the modules are set at a fixed tilt. But for applications 
that require a lot of water pumping during the summer, like 
irrigation, a sun-tracking PV module mount can maximize 
power production and pumping. 

Trackers keep the modules perpendicular to the sun as it 
moves through the sky, providing more power to the pump 
over a longer period of the day. In the summertime, a tracked 
system with a clear horizon-to-horizon solar window can 
provide 20% to 40% more water than a fixed array. 

Minimize Voltage Loss. To limit wiring voltage loss and minimize 
the length and the gauge of wire needed, locate the PV array as 
close to the pump or battery bank as possible. The greater the 
distance from the PV modules to the pump, the greater the 
voltage drop. Too much voltage loss can significantly reduce the 
amount of water pumped, and in some cases may be so great 
that the pump will not operate effectively. 

Voltage loss should not exceed the accepted standard of 2%. 
For long distances, wire size must be increased, at additional 
expense. With the price of copper at an all-time high, it's 
usually cost-effective to locate the array as close to the pump 
or battery bank as possible. Your system designer can provide 
the wire-sizing calculation for you, or you can use software 
provided by the pump manufacturer. 

Free Flow. Pipe friction is another important factor in 
optimizing pump production. The greaterthe distance between 
the pump's outtake and the delivery point, the greater the 
flow restriction from pipe friction. Much like voltage drop 
can be mitigated with larger wire size, flow restriction can be 
reduced by increasing the pipe size or reducing the distance. 
For household use, 1.25-inch- or 1.5-inch-diameter pipe is 



typical. However, if the distance exceeds 500 feet or the flow 
rate is expected to be unusually high, consider increasing the 
pipe diameter to 2 inches to keep friction losses down. 

Pump Protection. To regulate flow, pressurized systems use a 
pressure switch. If a holding tank is used, a float or level switch 
turns off the pump when the water rises to a certain level. 
Some pumps require a "reverse-acting" pressure switch. 
Most pressure switches operate by closing the contacts when 
the pressure has risen to a preset point. Conversely, in a 
reverse-acting pressure switch, the contacts open when the 
pressure falls to a certain level. 

Just as important is providing a shutoff mechanism for the 
pump. Damage can occur to the pump if it pumps against 
"shutoff" head when the holding tank is full and there's no 
overflow pipe or float switch in place. And to avoid damaging 
the pump if the water source runs dry, use dry-run protection (a 
water-level sensor) at the source. Some pumps have this built in, 
so check a given pump's specifications. 

Under Control. All submersible water-pumping systems should 
have a controller between the power source and the pump. In 
PV-direct systems, the control can be as simple as using a linear 
current booster (LCB). An LCB optimizes array voltage and 
current, maximizing the volume of water pumped and helping 
the pump start sooner in low-light conditions. More advanced 
controllers include pump motor speed-control and low-water 
cutoff circuits. Some even provide information related to the 
system status, including how many watts the PV modules are 
producing, and can be helpful for system troubleshooting. 
Most pump manufacturers offer one or more controller options 
designed to be used with their pump model. 

Arresting Lightning. Proper system grounding will usually 
protect the pump and control. But some manufacturer warranties 
also require a lightning arrestor be installed. As with any PV 
system, the array and its modules should be properly grounded. 
While a direct lightning strike will likely damage the controller, 
the pump may survive if the system is well-grounded. 



Lorentz manufactures a range of pumps, some of which 
operate at up to 200 volts open circuit. Centrifugal DC pumps 
manufactured by SunPumps operate at up to 245 Voc. They 
offer models that can pump 4 gpm from wells up to 650 feet 
deep, or up to 250 gpm from shallow wells or surface water 
sources. SunPumps and Shurflo also make less expensive 
diaphragm pumps that can be good choices in array-direct 
(batteryless DC from PV modules) applications for domestic, 
irrigation, or livestock watering, provided that the water is 
relatively silt free. 

Grundfos manufacturers the SQFlex, a centrifugal pump 
that can run on either AC or DC power — no special equipment 
is needed to make the switch. In DC systems, the pump only 
requires 30 VDC to get going, but the pump's 300-volt open- 
circuit limit allows the array to be wired at higher voltages, 
decreasing both wire size and cost. With the addition of a 
generator interface box, the pump can be switched to accept AC 
power from a generator during sunless periods. 




A Lorentz PS150 Boost diaphragm 
surface pump is typically used to 
pressurize water systems. 



home power 125 /June & july 2008 




Solar Pumping Systems 

There are three general solar water-pumping system types. 
Your best solution will depend on elevation changes at your 
site, whether there are inverters in your system, and how much 
flexibility you have when it comes to when you pump water. 

Array-Direct to Elevated Storage. The most efficient 
solar water-pumping systems are PV-direct without 
batteries. This classic off-grid pumping solution connects 
a DC submersible pump directly to the PV array. One 
additional component, either a controller or linear current 
booster (LCB) wired between the PV array and the pump, 
optimizes the relationship between array voltage and 
current to maximize the amount of water pumped under 
varying sunlight conditions. When the sun is shining, the 
pump moves water to a tank located above the water's point 
of use. (For potable water, use only drinking-water-grade 
tanks.) For each 2.31 feet of elevation, there will be 1 psi of 
water pressure. Many household water supplies operate 
at about 40 psi (though down to 20 psi can often work), 
so locating the storage tank about 100 feet higher than the 
point of use will provide adequate water pressure. 

The beauty of these systems lies in their simplicity. 
The tank acts as a large "battery," storing the pumped 
water for later use. And since the elevation of the tank 
provides the needed water pressure, no pressurizing 
pumps or pressure tanks are required. For household 
domestic water systems, I recommend sizing the storage 
tank to hold at least five days' supply of water to cover 
those inevitable periods of cloudy weather. If properly 
sized, the pump will slowly fill the tank when the sun 
is shining. When the sun isn't shining, the pump doesn't 
run. It does not damage the pump to go on and off during 
the day as clouds pass over. 

Other advantages of PV-direct pumping are the efficient 
use of PV energy (no losses to battery charging or inverter 
conversion) and the potential for reducing generator 
run-time. Off-grid system users often limit generator- 
based charging (and the associated noise, pollution, and 
fuel expense) by waiting to perform energy-intensive 
activities — like running the vacuum or shop tools — until 
there's plenty of solar energy available. This limits 
battery bank depth of discharge to extend battery life. In 
properly sized PV-direct to storage tank systems, several 
days' worth of water will be stored in the tank. During 
cloudy periods, you will already have pumped the water 
you need, and the generator won't be needed to keep the 
batteries topped off while pumping. 

Array-direct to elevated storage systems will save 
you money in the long run and add more flexibility to 
your off-grid energy lifestyle. But keep in mind that 
the additional expense of the tank and for trenching 
the pipeline deep enough for freeze protection can 
make these systems more expensive up front than other 
options. 

Array-Direct to Storage Tank with Pressure Pump. If you 

like the efficiency of DC pumping and want stored water at 
your disposal, but don't have enough of an elevation change 
on your property for a gravity system, there are still options. 



solar pumping 



Array-Direct to Elevated 
Storage 



Float Switch 



Storage Tank: 

Elevated 2.31 ft. for every 
psi of pressure needed; 
sized for days without 




Static Water Level 
Drawdown Level 



DC Submersible Pump: 

Sized for head to tank inlet 



Array-Direct to Storage 
Tank with Pressure Pump 

Photovoltaic Array: 

Sized for pump load 




Well 



StorageTank: 

At grade; sized for days 
without sun 



Static Water Level 
Drawdown Level 



DC Submersible Pump: 

Sized for head to top of tank 



www.homepower.corn 




3lar pumping 

A PV-direct DC pump can be configured to fill a storage tank 
near its point of use, and an additional DC or AC booster 
pump can be installed at the tank to pressurize the water. This 
solution gets the heavy lifting (from the well to the storage 
tank) done whenever the sun's shining, and limits energy 
use during cloudy periods to a smaller pressure pump that 
activates via a pressure switch when water is used. 

While this configuration gives you more flexibility to 
choose when you consume the energy required to pump well 
water, the up-front costs of the storage tank and additional 
pressure pump add to overall system cost and installation 
complexity. 

Pump to Pressure Tank. The most conventional of the 
three pumping systems described uses an AC submersible 
pump to push water directly to a pressure tank. A DC pump 
sized to meet the site's flow rate requirements can also be 
run directly from the battery bank, eliminating inverter 
conversion losses. A standard pressure switch activates the 
pump when the pressure in the tank drops below a set level, 
say 30 psi. At 50 psi or so, the switch's upper-limit shuts off 
the pump. Instead of a 1,200-gallon or larger water storage 
tank, a smaller 40- to 60-gallon pressure tank is all that is 
needed. 

Compared to the systems described earlier, pump-to- 
pressure tank systems usually have the lowest up-front 
component costs (there's no large storage tank or secondary 
booster pump), and pump installers everywhere are familiar 
with these systems. But they may not be familiar with the 
limitations of battery-based power sources (pump surge, 
inverter capacity issues, and the like), so pay close attention to 



Pump to Pressure Tank 




Photovoltaic Array: 

Sized for pump load 
or part of whole-house 
system 



Battery: 

For pumping 
at any time 



Pressure Tank: 

Charged by well pump, 
maintains house pressure 



Inverter: If AC system 
(not shown) 



Pump 

Controller 



Well 



Point 
of Use 



Static Water Level 
Drawdown Level 



AC or DC Submersible Pump: 

Sized for head to point of use, 
plus final pressure 




Installation of a Grundfos SQFlex submersible pump. 



the pump's operating characteristics and seek out an installer 
familiar with off-grid pumping systems whenever possible. 

For off-grid installations, the downside of pump-to- 
pressure tank systems is that the pump will need to come 
on during most water draws. During cloudy weather or 
overnight, the energy to repressurize the tank will come 
from your battery bank. Batteries like to be fully charged, 
and the deeper you discharge them and the longer they stay 
in that state, the shorter their service life will be. Another 
consideration is that, compared to array-direct systems with 
high-volume storage, increased generator run-time during 
cloudy weather will be a necessity. 



Access 

Erik Lensch is the owner of Innovative Solar Solutions 
(www.innovativesolar.com), based in Charlotte, North Carolina. 
Formerly SC Solar, the company has been designing and supplying 
solar water-pumping systems since 1999. 

Submersible Pump Manufacturers: 

Conergy • www.conergy.us • DC pressure & surface pumps 

Grundfos • www.grundfos.com • AC & DC/AC submersibles 

Lorentz • www.lorentz.de • DC pumps & solar trackers 

March • www.marchpump.com • AC & DC pressure pumps 

Shurflo • www.shurflo.com • AC & DC pressure pumps & DC 
submersibles 



SunPumps • www.sunpumps.com • DC pressure 
& submersibles 



home power 125 /june & july 2008 





GPS monitoring station at Cape Roberts, Antarctica operates year-round with solar power and a large bank of Deka Solar Gel Batteries. 



How Far Off The 



PROVEN PRODUCTS IN DEMANDING PHOTOVOLTAIC APPLICATIONS U.L. RECOGNIZED COMPONENTS COMPETITIVE WARRANTY MADE IN THE U.S.A. 



Photb Courtesy of UNAVCO 



EAST PENN INTERNATIONAL INQUIRIES: 
manufacturing co.,inc. 610-682-3263 9 www.dekabatteries.com 



DOMESTIC INQUIRIES: 

800-372-9253 9 www.mkbattery.com 



No matter where you are, depend on Deka Solar. 



Antarctica is the coldest continent on the planet. Only the toughest plants and animals are 
able to survive the cold. And the same goes for your batteries. So when a government 
funded agency needed to deploy a photovoltaic system for monitoring land mass 
movement in this harsh environment, they chose Deka Solar Batteries. 



Whatever the demands of your renewable energy application, Deka Solar Gel/AGM 
or flooded batteries are the proven choice. 



NEW from MORNINGSTAR . . . 




TM 



Maximum PV input of 400W 

• Enables use of high voltage 
modules up to 75Voc 

Converts up to 36 volt PV to 24V 
or 12V battery 

• Provides power boost and 
maximizes PV output 

• Smaller and less expensive than 
other MPPT controllers 



jidjil&t Mm 

Solar Controller with Maximum Power Point Tracking 



Please Visit Us at the MREA Energy Fair BOOTH A20 



O MORNINGSTAR 

1Y1 corporation 



Phone: +1-215-321-4457 Fax: +1-215-321-4458 
info@morningstarcorp. com www.morningstarcorp. com 



www.homepower.com 



The Solar Thermal Contractor’s Bible! 







DOWNLOAD NOW 

fJ^www ihu fan* you &vk 
LW fikmtt jlrii'.^Af rf Ctntayrra 
J CTm^uw 7 tVwfr Wdi i 

iwwvr,«c 3 ' 9 glar,cent 



1 







f.fw w£ J 2 i' 






Sotar Hal Water, Solar Space H eati ng. 
and Pool Healing; Installation and Ltestgn 
High Performance-Law Maintenance Systems 
Reality Checks Using Current Technology 



In this ckalmiCsve ?30- page manual, solar cnrgy pwnDer 
Tam Liw, In 20&& IrwlUettii Into thfl lull or f ume, 
tiuC&nes how E lie laleit Eechndegy and valuable lossens laamed 
from the past can help a new ger eraticn of solar contractors 
eipa nd their hiisinraus and liCisfy Ifttlf ciiitGflnen . 



Urzfcf miimhit frtw w.tfcs-sdjr.-eanO sm eredif card 
ar land 1 frhwt or -moniv rm 

Energy Conservation Services 

5JM Siv J3<*| St ■ dWmMfe fL $2603 

OSH} 3fMB6& 



i"rJcn Ii&SimL' DtspKS ? Sil S e»di — S_ 

K*i> and Vi r HCti EtiMft . C^rfcii ff &JB <*idi * 



l>GMTwisr:iG Shipping ariirHais<il*iQ; S i.M 
TOTAL: 5_ 




Solar Converters Inc. 



IVe design and manufacture Power Con frof SoJutrons for your PenekvaJife Energy Systems? 




Li nea r Currant DC ^ Battery Linear Voltage Generator 

Boosters Autotransformers DttlllphJtOrl Boosters Starter* 



frmuu Mar Pmrw 
PctfamwKa 

BFTpt 

r FlfHti U.l^ijl 


B*-BttVGtrariw} K*QC 
Comwlwt 

t ftafUPjs ■ Eqiijlir 

‘CffWl* F,ir*fv Pptf to 
DMwIWtW] 

- U£ I to Gtfrfcm 


t.r* rtdi tsiftn^Lirr 
* 6mwt 

■ WjvWWl F\it» Sain?ti 


K«Apx a Conitifrt flfttwy 
WHY#pf-toynurtgu^enr 
J tah*Y *vn i 

LiwUil^ 

- WBhf ftdTip Eo»i#f ifid 
GMolv 


Sfjrta / di l Lf>5 GttnS-rfi iMBfld 
an 

»Sfl^ipnifi94iv 

k TmfCenw i tlM 





also 4 MPPT Power Ti 3 Gker lv Charge Coelr oilers * Voltage Controlled Switches 
• Catfnd ic Proteclion Controllers * Solar Lighting Conlrollers 



Please visit www.solarconverters.coTn for MORE products and details 

CM» Victoria Road S. Guelph, On. Nl£ &T 9 , Canada Plmna ■: SI 9 -! 2 <-S 2 Xi Fan: 5 l«! 2 IHJ 325 tmall: lnto<gstf areMivcrtcf sjcom 



home power 125 /june & july 2008 




BackHome 



Magazine 



Free 

Wind Turbine 
..Plans 

lira BackHome 

FROM — Ml" 

Wind 

Build Your Own 

Low Cost > 




Wind Turbine 1 

Wbs* 1 1 

.$400 Estimated Cost ^ 

This low-cost, high-output f 


Subscribe to 

BackHome 

for just 


turbine is constructed of 


$21.97 per year. 


salvaged materials and can be 


Call us at 


built for about $400. To receive 


800-992-2546, 


your free PDF download of this 


write to us at 


plans booklet, just go to the 


P.0. Box 70hp, 


Web site below for details 


Hendersonville, NC 


and learn how BackHome can 


28793 or visit our 


“EM-POWER” you. 


Web site 



www.BackHomeMagazine.com 



“Its hard to imagine a more comprehensive, and 
comprehensible, guide to making your home work for you 
and for the planet, inside and out. Its frugal, its sensible, and it 
will help!” — Bill McKibben, author of Deep Economy and 
Fight Global Warming Now 



THE 

CARBON-FREE 

HOME 




3ft ■■'■ iil lli| n l-atlt li Hip- 




Chelsea 
Green 

PUBLISHING 

the politics and practice of sustainable living 




Visit us at: 



chelseagreen.com 

800.639.4099 




Quality First! 



TM 

Inc. 



SOLAR PUMPING PRODUCTS 




Brushless DC Submersible Pumps 
up to 2 HP. Heads up to 650 feet 
and flow rates up to 250 GPM. 




Diaphragm Submersible 
Pumps with heads up to 
230 feet and flow rates 
up to 5 GPM. 




Centrifugal Booster Pumps 
from 24 volt battery home 
pressure systems to 180 
volt panel direct systems, 
6 GPM to 30 GPM. 



DC Pool Circulating Pumps 
from y 2 HP to 1 y 2 HP, 

20 GPM to 100 GPM. 




PCA & PCB SERIES 




Micro-processor based pump 
controllers up to 3 HP. 

Current boosting and voltage 
boosting models available. 



PUMP CONTROLLERS 



SHARP 



For more products and services 
check our web site on-line at: 

www.sunpumps.com 



Phone: 

Fax: 



1 - 800 - 370-8115 
( 928 ) 348-9652 

( 928 ) 348-9653 



www.homepower.com 



81 















_ 




F 

T7 







For 28 years, my company has been 
helping its customers meet their energy 
needs with the power of the sun, but 
only recently, with our move into a 
new headquarters, have we been able 
to walk our talk by operating in a net 
zero-energy facility. When I started this 
business, working with only a part-time 
plumber, I never would have imagined 
that the company would grow to a 
team of more than 20 employees. With 
each new employee, I've become more 
and more aware of the energy impact 
of our day-to-day operations. 




home power 125 /june & july 2008 




net zero 



I n 2002, after almost ten years working out of a solar 
demonstration home that I had built near downtown 
Portland, Oregon, I moved our offices into a nearby 
commercial facility. Though the building suited our operations 
in many ways, it had one major drawback: The landlord 
would not allow us to put PV or solar hot water systems on 
the roof. 

Because I'm in the solar business, I dreamed of housing 
our offices and warehouse in an energy-efficient building 
with solar systems providing 100% of our energy needs. 
Though I initially had mixed emotions about starting over in a 
new building, I began to see the move as an opportunity — the 
first step in achieving zero net-energy use. 

Of course, while energy efficiency was a high priority, I 
had other considerations too — namely, I needed a loading 
dock. At our previous location, wheeling a 14-foot solar 
collector down the hallway, out the door, and hoisting it up 
onto the truck while cars sped by only a few feet away was 
precarious to say the least. So when I found a south-facing 
building with loading docks, it was a double bonus. The fact 
that the building was in a highly visible spot near Portland 
International Airport made it that much more appealing. 
Plus, the location was central to the city and Vancouver, 
Washington, where we perform most of our installations. 

The 10,000-square-foot building had been built as a 
sandblasting facility in 1950. More recently, it had been used 
by a trailer manufacturer, with a portion of the space divided 
into offices. The building was sturdy as a rock and had both 
single-phase and three-phase electricity. On the other hand, 
it was filthy, and the low ceilings and lack of windows in the 
office area made it dark and gloomy. For six months, I resisted 
purchasing the building just because I dreaded the work that 
I'd need to do to get it into shape. 

In December 2005, I finally gave in. The plan was to 
expand the existing office area, which had been sectioned into 



small rooms, to accommodate our showroom. The remaining 
8,000 square feet with 16-foot- tall, open- truss ceilings would 
become a warehouse, shop, and production area. 

Getting Comfy with Efficiency 

From an energy and comfort standpoint, the building was 
a disaster — and I wanted no part of the $l,500-per-month 
energy bills that the previous occupant reported. The office 
area had only two windows. The carpet was more blackish- 
gray than beige from years of hard wear and greasy boots. 
The whole space smelled like a mechanic's garage. Light- 
defying walnut paneling engulfed the four office walls. The 
ceilings were oppressively low and dingy. 

Improving Insulation. The only insulation in the building 
was ancient R-ll fiberglass batting haphazardly placed above 
the false ceilings in the office area. The first order of business 
was to blow an 18-inch- thick layer of new cellulose insulation 
right on top of the fiberglass. This filled in many of the voids 
and raised the insulation value in the attic to an estimated 
R-50. 

The building's exterior walls are 1-foot-thick concrete. 
The interior wall surface was furred with wood nailers 
and covered with paneling. We attached R-16 rigid-foam 
insulation sheets directly over the existing walls and installed 
new drywall over that. Though the layering reduced the size 
of our already-small offices, the added insulation made all the 
difference in comfort. 

Next, we searched for air leaks. We sealed all the ducts, 
replaced broken window panes, and weather-stripped the 
outside doors. Because all the electrical outlets and switches 
had to be extended 2.5 inches to accommodate the thicker 
walls, we even sealed out any drafts around the boxes with 
insulation pads specially made for this purpose. 

Lighting Strategies. The building's only natural light came 
from a bank of inoperable, steel-framed, single-pane windows 



Glass blocks, filled with water and dyes, are part of the 
showroom's daylighting strategy. 




Natural sunlight, 
provided by tubular 
skylights, brightens 
the office space. 



a 









net zero 




Tubular skylights bring sunlight into interior spaces to reduce 
daily lighting loads. 



on the south and west walls. A fresh coat of light-colored paint 
covered dark, ugly interior walls and helped to brighten the 
office space some, but the building needed serious help in the 
lighting department. We swapped out the existing 10-kilowatt 
lighting system — 40 industrial light fixtures drawing 250 
watts each — with industrial-sized tubular skylights, reducing 
the need for supplemental lighting during the day. Eight 
tubular skylights provide 90% of the lighting for the shop/ 
warehouse space and office during business hours. 

Next, we added two tube-fluorescent fixtures for task 
lighting in the production area. For our most creative lighting 
project, we fit 1-foot-square glass blocks — filled with water 
for thermal mass — into the frames of a permanently locked, 
south-facing garage door that had been covered with drywall 
by the previous owner. For an interesting and colorful effect, 
we added yellow and orange dye to the water in some of the 
glass blocks. 

All of these upgrades 
dropped our lighting 
load from 80 KWH to 
approximately 2 KWH per 
day, reducing our lighting 
costs by $240 per month. 

The skylights cost about 
$1,000 each, installed ($450 
materials; $550 labor). At 
present electricity rates, it'll 
take us less than three years 
to recoup our costs. 

Solar Water Heating. 

Within a year of moving into 
the building, we installed 



The storage tank (left) and 
the hot water collectors 
with the module for the DC 
pump (right) make up the 
solar water heating system, 
which provides 100% of the 
building's hot water. 




a solar water heating system and removed the backup 
electric water heater. Solar energy now provides 100% of the 
building's hot water, which serves two lavatories and two 
showers in the bathrooms. The system features a 56-square- 
foot thermal collector typically suited for a family of four. 
We located the solar storage tank in the showroom area so 
visitors can observe the water temperatures from the solar 
collectors — typically 140°F in the summer and 80°F in the 
winter. Even on the cloudiest days, visitors are pleasantly 
surprised to see the results of the system's PV-powered pump 
(a 12-volt DC Hartell pump directly powered by a 36 W 
module) in the glass flow meter. 

Space Conditioning. The mass of the slab-on-grade 
concrete floors in the building help moderate interior 
temperature swings. In the summer, the cool soil below 
the concrete floor tempers summer temperatures, while an 
awning shades the south-facing side of the building and 
prevents the summer sun from charging the concrete floor 
mass. As a result, our air conditioning unit is never used. On 
sunny wintertime days, the concrete absorbs solar energy, 
providing some offset for the electric air-source heat-pump 
system that serves the office space. 

To improve the efficiency and operation of the heat-pump 
system, which was installed in the 1950s, I hired an HVAC 
contractor to inspect and service the equipment. He inspected 
the ducts, sealed air leaks, and replaced the dirty, blackened 
filter that looked as if it was original to the system. For added 
conservation, I installed a programmable setback thermostat. 

Heating 2,000 square feet of segregated space efficiently 
takes some creativity and staff buy-in. Employees dress 
warmly in the winter, when the thermostat remains at 65 °F 
during work hours. As needed, a 1,000 W radiant electric 
heater supplements the main heating system in the colder 
back offices. Overnight, the programmable thermostat allows 
interior temperatures to drop as much as 20°F. But because the 
functional mass of the concrete floor tempers heat loss through 
the night, the space reheats quickly — about an hour after the 
thermostat turns on the heating system in the morning. 

The 8,000-square-foot warehouse is mainly used to store 
vehicles and renewable energy equipment inventory, so heating 
and cooling it is less of a priority. In the winter, which tends to 
be mild and mostly overcast, another 1,000 W electric radiant 
heater keeps temperatures tolerable in a production area. In the 
summer, two solar attic fans help by drawing hot air out. 




home power 125 /June & july 2008 



Running the Numbers 

After almost two years of tightening our energy belts and 
making efficiency upgrades, we were ready to calculate what 
it would take to reach net zero-energy usage. Our utility. 
Pacific Power, made it easy by providing a bar graph with 
the average daily KWH consumption for each month of the 
year. Upon poring over a year's worth of utility bills, we 
determined that our PV system would need to average at least 
23 AC KWH per day to offset our usage. 

From my experience, this load was on par with that 
of a highly efficient, all-electric home with passive solar 
design and solar hot water, and in which occupants practice 
energy conservation. In our case, besides space heating, we 
power one laptop and four desktop computers, a photocopy 
machine, a security system, and a dozen or so 15 W compact 
fluorescent lights in the office and showroom. We also have a 
total of six T-8 fluorescent tubes (32 W each) at task-lit stations 
in the production area. On a typical day, there are also six 
cordless-tool battery chargers plugged in. 

Once we determined the load, it was time to size the 
system. Peak sun is a standard measurement of the sun at its 
brightest, and varies depending on the location's weather, 
latitude, and other factors. One peak sun-hour is equivalent 
to 1 KWH per square meter per day. In other words, a 100% 
efficient solar module that's 1 square meter in size would 
produce 1 KWH per hour under the best circumstances — 
on the brightest day at high noon, with the PV module 
perpendicular to the sun and at a time of year when the sun 
is passing through the least amount of atmosphere. Of course, 
PV modules are really in the 11% to 19% efficiency range, but 
you get the picture. 

Most inhabited places have between 3 and 7 peak 
sun-hours per day. To calculate peak sun-hours in our 
location, we used the University of Oregon Solar Radiation 
Monitoring Laboratory's data. According to their analyses, 
average peak sun-hour equivalents for a fixed PV array in 
Portland are 3.9 hours per day. This assumes a true-south 
orientation, no shading, and a 30-degree tilt. 

We elected to mount the modules at a 15-degree tilt to 
aesthetically fit them to the space we had. The shallower 





For easier and speedier installation, the array was divided into 
three-module subarrays. 



angle reduces performance by about 4%, but the concession 
for the array's more streamlined appearance was worth it. 
We also recognized that there would be about 5% in losses to 
convert DC to AC through the inverter, and an additional 1% 
voltage drop through the wires carrying the solar-spawned 
electrons. This added up to 10% in reductions for our planned 
layout, leaving us with the equivalent of 3.5 peak sun-hours 
(90% of 3.9 peak sun-hours). 

It could be argued that a 15% correction factor might be in 
order, allowing for temperature derating, soiling, and other 
factors. However, we felt 10% would be a reliable number, 
given Portland's moderate average daytime temperature 
(62°F), plenty of rain to keep modules clean, and an awning- 
mounted system with excellent backside air circulation that 
keeps module operating temperatures lower than if they were 
mounted parallel to the roof. 

To calculate the size of the PV array we'd need, we 
divided the average daily KWH load by adjusted peak sun- 
hours to get the peak kilowatt rating of PV modules needed 
to reach net zero-energy. Although calculations showed that 



The Sunny Boy inverter, with the combined 
DC/ AC disconnect, and a KWH production meter. 




net zero 



Mr. Sun Solar's Grid-Tie PV System 




Inverter: 

Sunny Boy SB 6000US, 
6KW, 600VDC 
max input, 
250-480 VDC MPPT 




operating range, 
240 VAC output 



o 



o 



Sunny Boy 
AC/DC/Disconnect 
Combiner, 15 A fuses 
(representational) 




® 0 ®©@© 










Photovoltaic Array: 

Thirty-three Sharp ND-208U1F, 208 W each at 28.7 Vmp, 
wired in three series strings for 6,864 W total at 315.7 Vmp 



Note: All numbers are rated, 
manufacturers' specifications, or nominal 
unless otherwise specified. 



Utility KWH 
Meter 





we'd need a 6.57 KW array, it's good to oversize slightly. 
As it happened, 33 Sharp 208 modules in landscape layout 
perfectly fit the awning area we planned for the PV array. 
This configuration gave us a DC-rated 6.86 KW and a 4% 
margin of error in our estimate to reach zero. 

To verify the sizing, I ran another calculation based on the 
actual annual production of installed PV systems in the area. 
I had good data from several customers. One in particular 
had installed a 3 KW system three years prior. He found that 
he was getting an average of 1,214 KWH per year for each 
peak KW of PV on his roof. Using his real-world numbers, 
I multiplied 1,214 and 6.864 (the size of our PV array) to get 
8,333 KWH for the year. Dividing 8,333 by 365 days, I got 22.8 
KWH per day — almost exactly what we needed. 



System Rebates 

Item 


Amount 


Initial cost 


$67,500 


Incentives 


Oregon tax credit 


-$27,000 


Federal tax credit 


-11,670 


Energy Trust of Oregon rebate 


-8,580 


Total Incentives 


-$47,250 


Total Cost 


$20,250 



home power 125 /june & july 2008 




































net zero 



Configuring the System 

The array is comprised of three, 11-module strings, feeding 
a single SMA America Sunny Boy 6,000 W inverter. The SB 
6000US features a handy and time-saving extra — a built-in, 
four-pole disconnect, so both the AC and DC can be turned 
off with one switch. As required by Energy Trust of Oregon, 
we installed a Centron permanent KWH meter to keep an 
uninterrupted record of the system's AC output in the event 
that the inverter might have to be serviced. 

Before installing the system, we hired an engineer to make 
sure the steel awning on the front of the building would 
support a half-ton of additional module and racking weight. 
Once we received the thumbs up, we got to work, mounting 
groups of three modules together on the ground, which 
allowed us to precisely set two parallel underside rails to 
match the modules' bolt-hole pattern. Because someone had 
recently stolen modules from a similar awning mount system 
on a nearby building, we riveted cover plates over the bolts 



the net meter and brought along a photographer to cover 
the story for their company's newsletter. Our project was 
apparently big news, as it had established the first "truly" net 
zero-energy commercial facility in the company's six-state 
service district. 

Even as a solar installer who has personally completed 
almost 2,000 solar projects, I still get a thrill when flipping 
the switch for the first time. Ironically, the big moment was 
delayed by a local power outage caused by a car accident that 
had damaged a transformer. But we didn't let an outage slow 
down the party. We quickly rigged a battery-based portable 
PV system to provide electricity for lighting and music, 
including the ever-so-appropriate Beatles' classic, "Here 
Comes the Sun." We roasted hot dogs and baked cookies in 
solar cookers. 

Unfortunately, when we did finally flip the switch later 
that day after power had been restored, we discovered a 



as a theft deterrent. 

Using a boom lift, we raised each three-module group 
and positioned it on the frame. Four assistants put up the 
whole PV array in a day. We had already installed the 
inverter, had an electrician do the AC wiring, and ran 
conduit while waiting for the engineering report. It just 
took one more day to complete the DC wire run and then 
the system was ready to go. 

Throwing the Switch 

On August 25, 2007, the day after we finished installing the 
system, we hosted a "Throwing the Switch" open house to 
celebrate. Representatives from Pacific Power came to install 



Tech Specs 



Overview 

System type: Batteryless, grid-tie solar-electric 
Location: Portland, Oregon 

Solar resource: 3.9 average daily peak sun-hours 

Average monthly production: 694 AC KWH 
Utility electricity offset annually: 100% 

Components 

Modules: 33, Sharp ND-208U1F, 208 W STC, 28.7 Vmp 

Array: Three, 11-module series strings, 2,288 W STC 
each, 6.86 KW total, 315.7 Vmp 

Array installation: Custom 1.5 in. aluminum square tube 
mounts installed on south-facing awning, 15-degree tilt 

Inverter: SMA SB 6000US, with integrated 15 A fused 
combiner and AC/DC disconnect, 6 KW rated output, 
600 VDC maximum input, 250-480 VDC MPPT operating 
range, 240 VAC output 

System performance metering: Centron Itron KWH meter 



Paying for the System 

Professionally installed PV systems in our area run about 
$10 per peak watt. For the system I sized for our net zero- 
energy building, I was looking at an investment of almost 
$68,000. My first thought was, "Yikes! Where am I going 
to get that kind of money?" 

I considered the possibility of finding a third-party 
investor, who would buy the system, take the tax credits, 
utility incentives, and depreciation, and then lease the 
equipment to our business. In turn, we'd pay rent on the 
system for a cost roughly equal to the projected energy 
savings. However, since this option is generally used 
with larger systems, I had trouble finding a third party 
interested in our relatively small project. I did eventually 
have one taker, but in the end, the buy-out provision of 
the lease asked for "fair market value," which could have 
been $50,000 or more with appreciation — more than I 
was willing to pay. I didn't want to end up paying for the 
system twice. 

Instead, I found unsecured private financing at 7%. A low- 
interest loan through the state of Oregon's Solar Energy 
Loan Program would have come with a slightly more 
competitive rate, but the terms required that I take out a 
second mortgage on the building — which didn't appeal to 
me. Though I was not wild about taking on such a large 
loan, the numbers were less daunting once I factored 
in all the tax credits and incentives: an $8,580 rebate 
from the Energy Trust of Oregon; a $11,670 federal tax 
refund (30% of the system's cost, less the Energy Trust 
of Oregon incentive); and a $27,000 state tax credit taken 
over five years. 

In the first six months of the loan, I recovered about half 
of the loan amount. By the time all the credits come in, I 
will have covered nearly 80%. With all the incentives, the 
actual tax reduction from depreciation, and the value at 
current electric rates of the energy saved by the system, 
I estimate full payback in seven years. It was that easy. 
With just a few pushes of the pencil, I went from "Yikes! " 
to "Done deal!" 



net zero 



Phantom Protection 



Any net zero-energy home or business must zealously 
guard against phantom loads — energy that is gobbled 
up even when equipment is turned "off." To slay these 
energy wasters, we plug our photocopy/fax machine and 
every computer into power strips that are switched off 
every night. All devices with wall cubes are also plugged 
into power strips. We even went so far as to do away with 
a doorbell, and selected a microwave that does not have 
an LED clock. The building is as phantom-proof as we 
know how to make it. 

An exception — over coffee — was almost made when 
office java drinkers organized and requested an automatic 
coffee maker. Brewing coffee and keeping it hot all 
day was not something I was excited about, especially 
since I'm not a coffee drinker. But we compromised — I 
allowed the coffee maker, but only on the grounds that 
it is turned off immediately after coffee is brewed, and 
the coffee is transferred into an insulated dispenser that 
keeps it warm all day. 



technical problem — the SMA inverter kept blowing fuses. We 
got the company's technical support on the phone and worked 
through the possible scenarios. Based on their suggestion, we 
decided to rewire and bring the three individual strings into 
the inverter rather than combining them at the array. 



A week later, with the rewiring complete, we gave it 
another go on a gorgeous, sunny day. The system cranked 
out 31 AC KWH on that first day. And the best part: Our new 
Pacific Power bidirectional meter read zero when it was first 
installed, and the first number recorded was -1. There was 
nothing like watching the meter spin backward, knowing that 
we were well on our way to net zero-energy use. 



Access 

John Patterson (jp@mrsunsolar.com) is president of Mr. Sun Solar 
and inventor of the Sol-Reliant solar water heating system. Over 
the past 28 years, his company has installed more than 1,900 solar 
energy systems, including solar hot water, solar pool heating, and 
photovoltaic systems. 

Suzanne Olsen (suzolsen@integra.net) is a writer and photographer 
specializing in renewable energy and the environment. 

Tubular Skylights: 

Naturalite • www.vistawall.com 

Velux Sun Tunnel • www.veluxusa.com 



PV System Components: 

Sharp Solar • www.solar.sharpusa.com • PV modules 
SMA America • www.sma-america.com • Inverter 



SUPERIOR 



AESTHETICS 



SonFrame 



CLEAN ENERGY NEVER 
LOOKED THIS GOOD 



Our SunFrame PV module mounting system is 
engineered for exceptional function and design. 
Whether you are planning for your home or 
business, make an architectural statement while 
taking your environmental stand. 



Visit 



to find a distributor near you. 



UNIRAC 















THE STANDARD IN PV MOUNTING STRUCTURES 7 



www.unirac.com 



home power 125 /june & july 2008 



As per your request... 



T-Rex 

Charge Controller 
200 Volts PV Voc 
100 Amps output 
All the T80 features 

SOC Energy Meter 
Wireless Remote 
Optimal MPPT 



cm 




T80 Also 
available 




Off Grid 
Inverter/Charger 

Pure Sinewave 
3600W 48V 3200W 24V 

Split Phase 120/240VAC 




Wireless Remote 
Display 



Apollo 

Solar 



www.ApolloSolar.com 

203-790-6400 







gr Solar 




^^^iSotar 


*P/< 

c 


} 1 SunWize 

HU 


Aunttrar 




Visit us or write: 
Backwoods Solar Electric Systems, 
1589-HP Rapid Lightning Creek Rd, 
Sandpoint, Idaho 83864 USA 



For an earth restored and a world at peace. 

Solar • Wind • Hydro 



Specializing in Independent Electric Power for the Remote Home 
where utility power is not available. For 30 years, your questions have 
been personally answered by the good folks at Backwoods Solar that use 
these products everyday. Each Backwoods Solar employee owns and 
operates an off-grid home powered by the solar, wind, and/or micro- 
hydro systems offered in our catalog. We know what works and how it 
works! Our catalog /planning guide teaches the basics of installing solar, 
wind and hydro electric residential power and we offer free system 
design service either by telephone, email, or your visit to Backwoods. 



Phone: (208) 263-4290 • Fax only (208) 265-4788 
Website: www.backwoodssolar.com 
Email: info@backwoodssolar.com 



BACKWOODS 

Solar Electric Systems 



www.homepower.corn 





SOLECTRIA 

RENEWABLES 



GRID TIED INVERTERS 
for kW to MW systems 

Best Volue 
Fully Featured 
Premium Efficiency 
Easy to Install 

www.solron.com PH 978.6S3.97QD FAX 978.6e3.97p2 C A 562.608.8913 






o 

CM 

O 

CM 

a> 

■d 

o 



BAnERY System 
Monitor 




Displays vital battery system data to help users 
provide better battery care, increase conservation 
awareness and aid system maintenance. 



• Volts • Amps • Amp-hours • Min/Max volts 

• Days since charged • Battery % full 

• Remote locatable • About $169 



Bogart Engineering • (831) 338-0616 
www.bogartengineering.com 
020 Two Bar Rd. Boulder Creek, CA 95006 USA 




with more capability 

Data logging, five customizable buttons and displays, 
audible/visual alarms, three "amps" input channels, 
relay control, computer interface 

Is data logging really useful 
in a system monitor? 

When an offgrid system is first 
installed everything usually starts 
out working OK. But after awhile 
it may not work quite like it used 
to. Bad battery cell? Solar panel 
developed a problem? You can 
download the last few weeks of 
logged data to your computer and 
compare it to data recorded earlier 
when everything was working 
OK. Or email the file to some 
other "expert" who can analyze it 
without even coming to your home. 

On our website download the document: " How to graph 
and analyze renewable energy system performance using 
the PentaMetric logged data". 

The PentaMetric system with computer interface only is about 
$320. LCD Display unit (above) additional $199. 

See website for more information. 




home power 125 /june & july 2008 






Can something this beautiful really save you money? 



Y 



ou bet it can! The Sol-Reliant solar 



water heating system will pay for itself 
in energy savings within 3 to 7 years, 
depending on your hot water usage. 
Tax credits and incentives in some 
states pay up to half the cost or more! 

Sol-Reliant systems feature a photo- 
voltaic powered pump. They’re easy to 
install and reinstall after re-roofing. There ’s 
no visible plumbing, and best of all, Sol- 
Reliant systems won’t freeze or overheat. 
OG-300 and Bright Way certified. 



Designed to last over 25 years. 



S#L-REL1AINT 

The S&inr Fii'JJi-r f ft' titer Built To Last 



Dealer inquiries welcome! 

Call (888) SOL-RELY (888-765-7359) 



CCB#33716 

www.SolReliant.com 



EnengyTruSt 

f r I* - 




Industry Leaders In MPPT 
Solar Charge Controllers 

Look For New Products & New Ideas In 2008 




With the largest MPPT Solar Charge Controller product line 




on the market today, Blue Sky Energy, Inc. has a controller 
that’s right for your needs. From Solar Lighting, RVs & 
Marine to Telecom & many other off grid applications, 
Solar Boost™ Charge Controllers get the job done. 




Visit www.blueskyenergyinc.com 



Contact today for more info. 
800-4Jr7877 or 760-597-164^ 
2598 fortune Way, Suite K, 
■S^A92081 USA 
Hueskyener 2 yi 11 c.com 



SOLAR PUMPING LIGHTING 



MARINE OFF GRID HOMES 



QUALITY....RELIABILITY....BLUE SKY ENERGY, CHANGING THE WAY SOLAR IS USED EVERYDAY 



www.homepower.corn 



91 





Chuck Marken 
with Doug Puffer 



F or most of us, performance matters, whether we're 
shopping for a new car or choosing a solar water heating 
system. For cars, their estimated fuel economy — miles 
per gallon — can influence which model offers the best 
value. Although these EPA testing numbers aren't necessarily 
"real-world," they can give us a guideline to go by. Solar hot 
water (SHW) system performance is not much different. In 
this case, systems are evaluated by an independent testing 
agency — then certified by the Solar Rating and Certification 
Corp. (SRCC). And their ratings are the next best thing to real- 
world performance. 

Considering Your Choices 

Our list of solar water heating systems is condensed from 
the SRCC's Operating Guidelines 300 (OG-300) catalog, since 
we didn't have room to list the more than 500 SRCC certified 
systems. Instead, we tried to include every SHW system 
manufacturer, but pared the list to 130 individual systems, 
which were selected by two criteria: typical residential tank 
size (40 to 120 gallons) and typical collector sizing (1 square 
foot of collector area to every 1 to 2 gallons of water stored). 

Only seven or eight efficient systems per manufacturer 
were included in each climate category. To compare apples to 
apples, all the systems listed in our table are assumed to have 
electric backup heating. The included data is current as of March 
1, 2008 — for updates, visit the SRCC Web site. If you want a 



more detailed look at all the systems, but don't want to wade 
through the SRCC's 309-page catalog, check out our complete 
spreadsheet of OG-300 systems at www.homepower.com. 

System Certification 

In HP123, we featured a guide to selecting a solar hot water 
collector — the "engine" of a SHW system that gathers the 
energy. While the collector is the most important component 
in a solar water heating system, it is only one component of 
several that work together. Once the energy is gathered, it 
needs to be stored for on-demand use. The other components 
of an SHW system facilitate the storage and distribution of 
the solar-heated water, and greatly influence how much hot 
water is available. 

While choosing a collector is important, knowing how the 
entire system will perform is crucial. And getting an idea of how 
one system stacks up against another will help you maximize 
your investment. The SRCC OG-300 standards provide a 
relative performance comparison of various solar water heating 
systems. Certification requires testing the collectors under the 
OG-lOO standard and testing the entire system. (Note that 
some collectors are integrated with the storage tank, such as 
integral collector and storage and thermosyphon systems, and 
are listed only in the OG-300 catalog.) Before a system can be 
certified, a design and installation review, and a performance 
computation must be completed. 



home power 125 /june & july 2008 



Courtesy 



certified solar 



SRCC's OG-300 Certification Process 



SRCC OG-IOO: 




OG-300 


Collector test 




Design and Installation 






Guidelines Review: 




Drawings, 




^ T 


installation manual. 


System Test 




component labels 






TRNSYS 

Computer Modeling: 

Performance computation 



Certification: 

Rating label 



Collectors and systems are tested under standard 
laboratory conditions that are certain to be different from 
those at your home. Testing is a combination of durability 
and performance, with the test procedures for performance 
specified by the American Society of Heating, Refrigerating, 
and Air-Conditioning Engineers (ASHRAE Standard 93, 
"Methods of Testing to Determine the Thermal Performance 
of Solar Collectors"). 

What’s Your Climate? 

Before you select a system, you'll need to classify your climate 
area as either "mild" or "harsh." For the purposes of the table 
(see page 96), we split the list according to each system's 
freeze tolerance — or lack of it — and set the dividing line at 
10°F. 

However, since water freezes under different conditions 
of temperature, pipe size, liquid flow, insulation, and time, 
there are no hard-and-fast divisions — it's very difficult to give 
a rule that will work everywhere under all conditions. 



In "mild" climates, where freezing conditions are 
uncommon, potable water can be used directly in the collector 
loop. In SRCC lingo, this is a "Type I fluid system." These 
mild-climate systems have no heat exchangers, and are usually 
simpler and less expensive, with few components. However, 
because of their limited freeze tolerance, these systems, which 
include integrated collector storage (ICS) systems, direct 
forced-circulation systems, and open-loop thermosyphon 
units, are generally limited to installation in Hawaii and the 
southernmost part of the United States — states that border 
Mexico or the Gulf of Mexico. 

The rest of the United States is classified as falling in 
the "harsh" climate, since the probability of freezing is 
far greater. These areas are best served with true freeze- 
tolerant systems, which have heat exchangers, and are either 
drainback systems that use potable water (Type I fluid 
system) or nontoxic antifreeze systems (Type II fluid system). 
The SRCC catalog refers to these systems as "indirect forced- 
circulation systems." 



Solar Hot Water System -Types Compared 



System Type Climate & Description Advantages Disadvantages Installation 



Integral Collector 
Storage (ICS) 


Passive: Open loop for 
mild climates 


Simplicity; lowest cost 


Poor freeze protection; 
poor tank insulation 


Heavy units; easy 
to install; can have 
cosmetic-appearance 
issues 


Thermosyphon 


Passive: Open loop for 
mild climates; closed 
loop can be used in 
harsh climates 


Simple open loop; 
tank is insulated 


Open loop has poor 
freeze protection; 
closed loop needs 
a heat exchanger; 
potable water lines 
to collector subject to 
freezing 


Very heavy systems; 
easy to install; can have 
cosmetic-appearance 
issues 


Direct Pump: 

Direct circulation 


Open loop for mild 
climates only 


Simple active system; 
can be PV powered 


Poor freeze protection; 
freeze valves can give 
false security 


Easy installation; needs 
electrical source 


Drainback: 

Closed loop, forced 
circulation 


Closed loop for all 
climates 


Simple system when 
compared to antifreeze 
systems; limited 
overheating 


Needs a high-head 
pump and heat 
exchanger; harder to 
power with PV 


Slope of collectors and 
piping is critical 


Closed-Loop 

Antifreeze: 

Forced circulation 


Closed loop for all 
climates 


Best freeze protection; 
easily PV powered 


Most complex; can 
have overheating 
problems; needs a heat 
exchanger 


Most difficult 
installation 



www.homepower.corn 









certified solar 



MILD CLIMATE SYSTEMS 



Integral Collector Storage 

Passive ICS systems (batch water heaters) are the simplest 
solar water heater. Cold water flows under normal water 
pressure to the bottom of the tank, and hot water is taken 
off the top. Whenever there's a call for hot water, hot water 
moves from the top of the solar batch heater as cold water is 
pushed into the bottom. Most of the ICS units produced in 
the United States today are progressive-tube-type heaters as 
opposed to single-tank units. Although the storage tank(s) of 
ICS systems are freeze-tolerant in normal operation, the weak 
point in the system is the potable water pipes running to and 
from the units. These systems are climate limited and are 
included in the mild-climate listings. (For more information 
on ICS systems, see HP 9 3 & HP 10 8.) 

Thermosyphon 

These systems position an insulated solar storage tank higher 
than the collector, relying on the principle of heat rising to 
move water through the system. These open-loop systems 
are more climate-limited than ICS systems because the 
small riser tubes in the collector are vulnerable to freezing. 
However, thermosyphon systems can be configured in a 
closed-loop design, using antifreeze in the collector and a 
heat exchanger and potable water in the tank. Because closed- 
loop thermosyphon systems have potable domestic water 



lines to and from the collector, their Achilles' heel, they are 
vulnerable to freezing. 

The advantage of this system over the batch heater is 
that solar heat is stored in a well-insulated tank, so hot water 
can be used any time with lesser penalty of overnight losses. 
The SRCC lists open-loop systems as "direct thermosyphon" 
and closed-loops as "indirect thermosyphon." (A direct 
thermosyphon system is described in detail in HP 97.) 

Direct Pump 

Used in tropical settings where freezing never occurs, this 
is the simplest of the active systems, using a pump and a 
standard tank with electrical elements teamed with a solar 
thermal collector. A direct-pump system is also known as a 
"direct-forced circulation" system by SRCC classifications. 
In this open-loop system, the collector-loop fluid is potable 
water. As with ICS and open-loop thermosyphon systems, 
potable water must run outside to the collector, and the 
associated plumbing is vulnerable to freezing. A weaker freeze 
link is the smaller riser tubes connected to the header tubes. 
They are subject to freezing before the insulated potable water 
lines. Direct-pump systems can easily be married to a PV 
module that will power a DC pump. Direct forced-circulation 
systems are very popular in places like Hawaii, which has 
mild temperatures and plenty of sunshine. 



Freeze-Protection Gizmos— 
Caveat Emptor 



In an attempt to have their systems reclassified to gain 
more sales, some manufacturers have incorporated freeze- 
protection schemes into their "mild climate" systems. The 
bottom line? Buyer beware if you're considering installing 
one of these systems in your "harsh" climate. Only two 
designs — drainback and antifreeze systems — offer reliable 
freeze protection in these areas. Here are some freeze- 
protection devices that have caused collectors to freeze in the 
past — and consequently have required expensive repairs or 
replacement. 

Direct pump with recirculation. Some differential controls 
for turning pumps on and off also have a "freeze-protection 
feature" that can be set to recirculate water from the storage 
tank to the collector. The logic is that the warmed, stored water 
can be routed to the collector to prevent it from freezing. But 
this method has ruined collectors when unusually bad winter 
storms move in and power outages occur. Without electricity 
to power the control and pump, water can stagnate in the 
collector, and a hard freeze can burst the collector riser tubes. 



Freeze valves (a.k.a. dribble valves). For freeze protection, 
some direct-pump, ICS, and thermosyphon systems use a 
freeze valve, a passive valve that is set to open at a low 
temperature (either 35°F or 45°F). When the valve opens, 
water from the municipal or well system enters the collector, 
and the near-freezing water in the collector dribbles from the 
valve onto the roof or the ground. Although this strategy is 
perhaps more reliable than recirculation systems, it is far from 
fail-safe. Hard (mineral-laden) water can eventually clog the 
valve, and poof! — the supposed freeze protection is gone. 

Draindown valves, which were incorporated into direct-pump 
systems all over the United States, have been one of the worst 
hiccups in solar-thermal history. At a preset, low temperature, 
a controller activated the valves to divert water in the collectors 
to drain outside. However, like freeze valves, draindown valves 
were prone to failure due to corrosion, hard-water deposits, 
and clogging. Typically, the first winter freeze ruined the 
collector — when the valve failed, the collectors remained full 
of water and froze. 



home power 125 /June & july 2008 




certified solar 



HARSH CLIMATE SYSTEMS 



Drainback 

These indirect forced-circulation systems are reliable, 
freeze tolerant, and fairly easy to install. The closed-loop 
drainback system requires perhaps the least amount of 
maintenance of any indirect, active system. The heat- 
transfer fluid is distilled water, which seldom has to 
be changed. When the system is not pumping, the 
solar collector is empty with the water having drained 
to the reservoir tank, usually located just above the 
solar storage tank. Higher-capacity reservoir tanks are 
typically required in large systems. The system relies on 
the collectors and piping being drained when freezing 
conditions are possible. Both are sloped toward the 
drainback tank so that when the pump turns off, the water 
in the collector loop passively drains back into the tank. 

Since the pump must have enough power to push 
water from the drainback-tank fluid level to the top of 
the collectors — a distance that can be 20 or 30 feet — most 
installations require a high-head pump. Because of the head 
requirements and the limited choices in DC pumps, drainback 
systems are tougher to adapt to direct PV power. (Drainback 
systems are featured in HP 8 6 & HP 97.) 



Antifreeze 

This is the most complex indirect forced-circulation, closed- 
loop system — and therefore the most difficult to install. It also 
is the system with the best freeze protection, and as such, is 
popular in northern climates. 

In this active, closed-loop system, incoming potable 
water is routed to the solar storage tank, but never into the 
collectors. A water-antifreeze mixture circulates from the 
collectors through a heat exchanger and then is pumped back 
through the collectors. 

Antifreeze systems can overheat in the summer if there 
is too much collector surface area relative to tank storage 
volume. Overheating can be combated by using the 'Vacation 
mode" of newer differential controls, which will allow 
fluid to circulate through the system at night, cooling the 
fluid. PV-powered systems can incorporate a bypass valve 
around the check valve, which will allow the system to 
reverse thermosyphon at night to cool the antifreeze. (See 
Bob Inouye's article in HP123 for details of a bypass valve. 
Antifreeze systems were covered in depth in HP85 & HP95.) 
For a good overview of the five systems mentioned here, see 
"Solar Hot Water: Simplified" in HP107. 



Basic Open-Loop 
System 



Cold to Collector: 

Potable water in 
collector loop 



Solar Thermal 
Collector 



Hot from 
Collector 



Basic Closed-Loop 
System 



Cold to Collector: 

Antifreeze in 
collector loop 



Solar Thermal 
Collector 



Hot from 
Collector 




Hot Out: 

Potable to house 
or backup heater 



Note: Pumps and other 
components not shown 



Heat Exchanger: 

External (shown) or 
internal;Transfers heat 
without mixing fluids 



Cold Supply In: 

Potable 




Hot Out: 

Potable to house 
or backup heater 



Note: Pumps and 
other components 
not shown 



www.homepower.corn 



MILD CLIMATE SYSTEMS 



certified solar 
TABLE SPECS 

Freeze-Tolerant Temperature — The temperature at which 
manufacturers estimate some part of the system is vulner- 
able to freezing. The SRCC says that " unless a system is 
installed in a nonfreezing climate, every system must have 
an automatic mechanism to at least partially protect it 
from freezing (i.e., automatic draining, antifreeze fluids, or 
thermal mass)." 

Collector Size — The collector size for a given system is 
determined by the storage-tank volume and the amount 
of sunlight available at the installation site. The size of the 



collector is important: It must be large enough to do the job but 
not so big that it is a waste of money or causes overheating. 

Storage Tank Size — System sizing is normally based on a 
one-day recovery time, which means that the storage tank 
should be large enough to satisfy the demands of a household 
for one day, at a minimum. 

Annual KWH Saved — The SRCC catalog boils performance 
data down to savings estimates — given in annual estimated 
KWH — in several cities. We chose San Diego; Richmond, 
Virginia; and Seattle to represent sunny, partly cloudy, and 
cloudy climate conditions, respectively. The SRCC has modeled 



Manufacturer 



Freeze Tolerant 
Temp. (°F) 



Collector Size Storage Tank Size 
(Sq. Ft.) (Gal.) 



Annual KWH Saved 



San Diego, CA 



Richmond, VA 



Seattle, WA 



ACR Solar Inti. 


30 ° 


40.1 


50 


2,600 


2,100 


1,700 


Energy Laboratories 
Inc. 


22 ° 


30.8 


68 


2,500 


2,100 


1,600 



Heliodyne Inc. 



27 ° 


53.5 


80 


3,600 


3,200 


2,600 


27 ° 


64.5 


120 


3,700 


3,300 


2,700 


27 ° 


64.5 


80 


3,600 


2,900 


2,400 


27 ° 


80.3 


120 


3,500 


3,400 


2,900 


27 ° 


80.3 


120 


3,800 


3,500 


2,900 


27 ° 


96.7 


120 


3,700 


3,100 


2,500 


27 ° 


120.4 


120 


3,500 


3,400 


3,000 



Integrated Solar LLC 


20 ° 


25.0 


40 


1,500 


1,200 


1,000 


20 ° 


33.2 


50 


1,900 


1,600 


1,300 


Rheem Water Heaters 


19 ° 


42.7 


77 


2,200 


1,600 


900 



19 ° 


85.4 


113 


3,300 


2,500 


1,600 


19 ° 


85.4 


113 


3,300 


2,500 


1,600 


19 ° 


64.0 


77 


3,000 


2,600 


2,100 


19 ° 


85.4 


113 


3,200 


2,800 


2,200 


19 ° 


85.4 


113 


3,200 


2,800 


2,300 


41 ° 


64.0 


90 


3,500 


2,700 


2,200 


41 ° 


64.0 


114 


3,600 


2,700 


2,200 



Solnhnrt Industries 



Solene 



20 ° 


64.0 


120 


3,500 


3,100 


2,500 


20 ° 


80.1 


120 


3,700 


3,600 


3,000 


20 ° 


60.6 


80 


3,800 


3,500 


2,800 


20 ° 


80.1 


120 


3,900 


3,900 


3,100 


20 ° 


77.7 


120 


3,700 


3,500 


2,900 


20 ° 


63.6 


120 


3,800 


3,600 


2,800 


20 ° 


77.7 


120 


3,800 


3,800 


3,000 



SunEarth Inc. 



20 ° 


39.7 


64 


2,400 


2,000 


1,700 


20 ° 


49.8 


84 


2,600 


2,200 


1,800 


41 ° 


40.9 


80 


3,000 


2,500 


2,000 


41 ° 


40.9 


80 


3,100 


2,600 


2,000 


15 ° 


73.9 


116 


3,000 


2,600 


2,100 


15 ° 


81.7 


116 


3,300 


2,800 


2,300 


15 ° 


65.7 


80 


3,000 


2,500 


2,000 



10 ° 


32.1 


40 


2,200 


1,900 


1,500 


10 ° 


32.1 


50 


2,300 


1,900 


1,500 



Thermal Conversion 
Technology Inc. 



home power 125 /june & july 2008 




certified solar 



the systems data for many other cities in the United States and 
also provides listings on systems with gas backup, which are 
not included in our condensed table. 

System Type — The catalog lists the systems by four types: 
integral collector storage (ICS, a.k.a. batch water heater); 
thermosyphon systems (open and closed loop); forced- 
circulation systems (direct pump, drainback, and antifreeze); 
and self-pumping systems. (Note: There are no self-pumping 
systems currently certified.) 

Controller — Found only in forced-circulation (active) systems, 
controllers energize the system pump at the appropriate time. 



There are differential controllers, systems without controllers, 
and systems that use a PV module to automatically turn on 
the pump when the sun shines. 

Fluid Used — Only two types of fluids, water (Type I fluid) 
and nontoxic propylene glycol antifreeze (Type II) mixed 
with water, are used in modern SHW systems. 

Heat Exchanger — Transfers the energy collected by the 
collector-loop fluid to the domestic water used in the 
home. The type and size of heat exchanger can influence 
the system efficiency significantly. (For more info, see 
HP92.) 



System Name 


System Model 


System Type 


Collector Model 


Aux. Tank 
Size (Gal.) 


Fluid 


Controller 


Supply-Side 
Heat Exchanger 


Skyline System 3 


200132C502TE 


Direct Forced 
Circulation 


ACR Solar 20-01 


50 


Water 


PV Panel 
Controller 


None 




Roof Integrated 
Thermosyphon 


RITH 72 E 


Direct 

Thermosyphon 


Energy Lab. RITH-72 


50 


Water 


None 


None 







HF 23366 G 80 AC S E 




Heliodyne - 336 000 












HF 2408 G 120 AC S E 




Heliodyne - 408 000 


None 










HF 2408 G 80 AC S E 


Direct Forced 
Circulation 


Heliodyne - 408 000 






Differential 

Controller 




Helio-Flo 


HF 2410 G 120 AC D E 


Heliodyne - 410 000 


50 


Water 


None 




HF 2410 G 120 AC S E 


Heliodyne - 410 000 


None 








HF 3408 G 120 AC S E 




Heliodyne - 408 000 










HF 3410 G 120 AC D E 




Heliodyne - 410 000 


50 









Sun Systems - CS 340 


50 


Sun Systems - CS 450 


50 



CopperSun 



CS340SV-E 



CS450-E 



Direct Integral 
Collector Storage 



Water 



None 



None 







Indirect 

Thermosyphon 










Mantle Heat 


Rheem Solaraide 


RS80-42BP 


Rheem - RS21-BP 


None 


Glycol 


None 


Exchanger with 
a Single Wall 



Glycol 


None 


Mantle Heat 
Exchanger with 
a Single Wall 


Water 


Differential 

Controller 


None 



Solahart 



Streamline Electric 



444BCXII 



444KF & 444KF Free Heat 



ASE 303BCXII 



ASE 444BCXII 



ASE 444KF & ASE 444KF 
Free Heat 



340SL-3Bt 



430SL-3Bt 



Indirect 

Thermosyphon 



Direct Forced 
Circulation 



Solahart - KF 



Solahart - Bt 



None 



Solene/Chromagen 


SLCR64DC-80 




Solene - SLCR-32 






Differential 




DC Open Loop 


SLCR80DC-120 




Solene - SLCR-40 






Controller 




Solene/Chromagen 


SLCR60PV-80 




Solene - SLCR-30 






PV Panel 




PV Open Loop 


SLCR80PV-120 


Direct Forced 


Solene - SLCR-40 


None 


Water 


Controller 


None 


Solene/Corona DC 
Open Loop 


SLC080DC-120 


Circulation 


Solene - SLCO-40 


Differential 

Controller 


Solene/Corona PV 


SLCO64PV-120 




Solene - SLCO-32 






PV Panel 




Open Loop 


SLC080PV-120 




Solene - SLCO-40 






Controller 





CopperHeart 


CP-60P 


Direct Integral 
Collector Storage 


SunEarth - CP-30 


50 


CP-80P 


SunEarth - CP-40 


50 


SunSaver 


NF40P-80S 


Direct Forced 
Circulation 


SunEarth - EP-40 


None 


NF40P-80T 


SunEarth - EP-40 


SunSiphon 


EPGX1 16-63-2 


Indirect 

Thermosyphon 


SunEarth - EP-24 


50 


EPGX1 16-80-2 


SunEarth - EP-40 


50 


EPGX80-64-2 


SunEarth - EP-32 


50 



Water 



None 



Differential 

Controller 



None 



Glycol 



None 



Mantle Heat 
Exchanger with a 
Single Wall 



TCT - PT-40-CN 


50 


TCT - PT-50-CN 


50 



ProgressivTube 



PT-40-CN 



PT-50-CN 



Direct Integral 
Collector Storage 



Water 



None 



None 



www.homepower.corn 



MILD CLIMATE SYSTEMS 




HARSH CLIMATE SYSTEMS 



certified solar 



Manufacturer 


Freeze Tolerant 


Collector Size 


Storage Tank Size 




Annual KWH Saved 




Temp. (°F) 


(Sq. Ft.) 


(Gal.) 


San Diego, CA 




Richmond, VA 


Seattle, WA 


ACR Solar Inti. 


-54° 


40.1 


80 


2,300 


1,900 


1,600 


-54° 


40.1 


80 


2,200 


1,800 


1,500 





Alternate Energy 
Technologies 


-20° 


98.0 


120 


3,200 


3,000 


2,400 


-20° 


63.8 


120 


3,300 


3,100 


2,500 


-20° 


65.3 


120 


3,300 


3,100 


2,500 


-20° 


79.6 


120 


3,400 


3,300 


2,700 


-20° 


63.8 


80 


3,300 


3,000 


2,400 


-20° 


65.3 


80 


3,300 


3,000 


2,400 


-20° 


79.6 


80 


3,400 


3,200 


2,600 



BFT Ltd. 


-50° 


33.1 


65 


1,500 


1,300 


1,100 


-50° 


66.2 


80 


2,400 


2,000 


1,700 



Bobcat & Sun Inc. 


-60° 


64.5 


80 


2,800 


2,500 


2,000 


-60° 


64.5 


80 


3,000 


2,700 


2,200 


-60° 


64.6 


80 


2,900 


2,600 


2,100 


-60° 


65.7 


80 


2,900 


2,600 


2,100 



Butler Sun Solutions 


-54° 


40.9 


80 


2,400 


2,000 


1,600 


-54° 


40.9 


80 


2,500 


2,000 


1,500 


-54° 


40.9 


80 


2,500 


2,000 


1,500 



Enerworks Inc. 


-50° 


61.9 


80 


3,000 


2,700 


2,200 


-50° 


92.8 


120 


2,700 


2,500 


2,200 



Fafco Inc. 


-20° 


47.4 


50 


1,800 


1,500 


1,300 


-20° 


47.4 


80 


1,900 


1,600 


1,300 


-20° 


94.9 


50 


2,200 


1,800 


1,500 


-20° 


94.9 


80 


2,300 


2,000 


1,600 




Heat Transfer 
Products 


-60° 


43.6 


80 


NA 


NA 


NA 



Heliodyne Inc. 


-60° 


53.5 


80 


3,200 


2,800 


2,200 


-60° 


64.5 


120 


3,300 


3,000 


2,300 


-60° 


80.3 


120 


3,500 


3,200 


2,600 


-60° 


53.5 


80 


3,400 


2,800 


2,200 


-60° 


80.3 


120 


3,600 


3,200 


2,600 


-60° 


80.3 


120 


3,600 


3,200 


2,500 


-60° 


96.7 


120 


3,700 


3,400 


2,700 



Integrated Solar LLC 


-60° 


79.8 


120 


3,000 


2,500 


1,900 


-60° 


39.9 


65 


2,200 


1,800 


1,400 


-60° 


39.9 


80 


2,700 


2,300 


1,800 



Morley 

Manufacturing 


-60° 


39.9 


60 


2,500 


2,000 


1,600 


-60° 


40.1 


60 


2,500 


2,000 


1,600 


-60° 


40.9 


60 


2,500 


2,000 


1,600 



Mr. Sun Solar 


-50° 


39.8 


80 


2,900 


2,500 


2,000 


-50° 


55.7 


80 


3,400 


3,000 


2,400 



home power 125 /june & July 2008 




certified solar 



System Name 


System Model 


System Type 


Collector Model 


Aux. Tank 
Size (Gal.) 


Fluid 


Controller 


Supply-Side 
Heat Exchanger 


Skyline System 5 


200152C80EX 


Direct Forced 


ACR Solar 20-01 


None 


Glycol 


PV Panel 


Tank Wraparound 
Heat Exchanger 
with Double Wall 
and Positive Leak 
Detection 


200152C80EX2TE 


Circulation 


ACR Solar 20-01 


50 


Controller 



EagleSun 


DB-120-96 




MSC-32 








Tank Wraparound 
Heat Exchanger with 
a Single Wall 




DX-1 20-64 


Indirect Forced 
Circulation - 
Drainback 


AE-32 












DX-1 20-64 


MSC-32 


None 


Water 


Differential 




EagleSun DX 


DX-1 20-80 


AE-40 


Controller 


Immersed Coil Heat 
Exchanger with a 
Single Wall 


DX-80-64 




AE-32 










DX-80-64 




MSC-32 










DX-80-80 




AE-40 











BFT - SP-20 


50 


BFT - SP-20 


50 



Solar Patriot 



SP20-1-65G-PV-E 



SP20-2-80G-PV-E 



Indirect Forced 
Circulation - 
Antifreeze 



Glycol 



PV Panel 
Controller 



Immersed Coil Heat 
Exchanger with 
a Double Wall 



Heliodyne - 408 000 


None 


Heliodyne - 408 000 


None 


Radco - 408P-HP 


None 


SunEarth - EP-32 


None 



Sun-Pak 



SP64CHE 



SP64CHE-1 



SP64PHE-1 



SP64PHE-1 



Indirect Forced 
Circulation - 
Antifreeze 



Glycol 



Differential 

Controller 



Tank Wraparound 
Heat Exchanger 
with Double Wall 
and Positive Leak 
Detection 





BSS-PV1-80E2b 


Indirect Forced 
Circulation - 
Antifreeze 


SunEarth - SC-40 


50 




PV Panel 


Immersed Coil 


Solar Butler 


BSS-PV1-80Ea 


SunEarth - SC-40 




Glycol 


Controller 


Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 


BSS-S1-80Ea 


SunEarth - SC-40 


None 


Differential 

Controller 



Solar Water 
Heating Appliance 



EWRA2-E80 



EWRA3-E120 



Indirect Forced 
Circulation - 
Antifreeze 



Enerworks - COL-4x8-TL- 
SG1-SD10US 


50 


Enerworks - COL-4x8-TL- 
SG1-SD10US 


50 



Glycol 



Differential 

Controller 



Plate Heat Exchanger 
with a Single Wall 





VDB-48U-50E-50S 






50 








Polymer Drainback 


VDB-48U-50E-80S 


Indirect Forced 
Circulation - 
Drainback 


Fafco - Revolution 


50 


Water 


Differential 


Plate Heat Exchanger 


VDB-48UX2-50E-50S 


50 


Controller 


with a Single Wall 




VDB-48UX2-50E-80S 






50 









SuperStor 
Contender Solar 


SSC-80SE 


Indirect Forced 
Circulation - 
Antifreeze 


Apricus - AP-30 


None 


Glycol 


Differential 

Controller 


Immersed Coil Heat 
Exchanger with 
a Single Wall 





16 DWCL HP 2 3366 G 
80 ACS 




Heliodyne - 336 000 










Heliopak 


16 DWCL HP 2 408 G 
120 ACS 




Heliodyne - 408 000 






Differential 

Controller 






16 DWCL HP 2 410 G 
120 ACS 


Indirect Forced 
Circulation - 
Antifreeze 


Heliodyne - 410 000 








Shell-and-Tube 
Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 




HP HX SS 2 3366 G PV 
80 EES 


Heliodyne - 336 000 


None 


Glycol 




Helio-Pak Helix 


HP HX SS 2 410 G PV 
120 SE S 


Heliodyne - 410 000 






PV Panel 


SS PV 


HP HX SS 3 3366 G PV 
120 SE S 




Heliodyne - 336 000 






Controller 






HP HX SS 3 408 G PV 
120 SE S 




Heliodyne - 408 000 











RadCo Drainback 
Heat Exchanger 


R-DBHX-8-120S-80P 


Indirect Forced 


Radco - 410P-HP 






Differential 

Controller 


Immersed Coil Heat 


R-DBHX-8-65S-40P 


Circulation - 


Radco - 410P-HP 


None 


Water 


Exchanger with 


R-DBHX-8-80S-40C 


Drainback 


Radco -410C-HP 






a Single Wall 



High Sierra 
Drainback 



HS60B/40 



HS60B/40 



HS60B/40 



Indirect Forced 
Circulation - 
Drainback 



Radco -410P-HP 


50 


Heliodyne - 410 000 


50 


SunEarth - EC-40 


50 



Water 



Differential 

Controller 



Shell-and-Tube Heat 
Exchanger with 
a Single Wall 



AE-40 


50 


AE-56 


50 



Sol-Reliant 



SR 40/80 E PVDB 



SR 56/80 E PVDB 



Indirect Forced 
Circulation - 
Antifreeze 



Glycol 



PV Panel 
Controller 



Tank Wraparound 
Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 



www.homepower.corn 



HARSH CLIMATE SYSTEMS 




HARSH CLIMATE SYSTEMS 



certified solar 



Manufacturer 


Freeze Tolerant 


Collector Size 


Storage Tank Size 


Annual KWH Saved 




Temp. (°F) 


(Sq. Ft.) 


(Gal.) 


San Diego, CA 


Richmond, VA 


Seattle, WA 




-40° 


58.1 


80 


3,000 


2,700 


2,200 


Schuco USA L.P. 


-40° 


87.1 


120 


3,300 


3,100 


2,500 


-40° 


49.7 


80 


2,900 


2,500 


2,100 




-40° 


74.6 


120 


3,300 


3,000 


2,400 



Solar Energy Inc. 


-20° 


115.7 


120 


3,400 


3,100 


2,500 


-20° 


119.4 


120 


3,400 


3,100 


2,500 


-20° 


95.7 


120 


3,300 


3,000 


2,300 


-20° 


98.5 


120 


3,300 


3,000 


2,300 


-20° 


65.6 


80 


3,100 


2,700 


2,200 


-20° 


77.1 


80 


3,200 


2,900 


2,300 


-20° 


79.6 


80 


3,200 


2,900 


2,300 



Solarhot 


-10° 


64.0 


80 


3,400 


3,200 


2,600 


-10° 


64.5 


80 


3,400 


3,200 


2,600 



Solene 


-10° 


60.6 


80 


3,200 


2,900 


2,300 


-10° 


64.0 


80 


3,300 


2,900 


2,400 


-10° 


63.6 


80 


3,200 


2,800 


2,300 


-10° 


77.7 


80 


3,400 


3,000 


2,500 


-10° 


77.7 


80 


3,200 


2,900 


2,300 


-10° 


63.6 


80 


3,200 


2,800 


2,300 


-10° 


77.7 


80 


3,400 


3,000 


2,500 



Stitt Energy 
Systems Inc. 


-40° 


79.6 


120 


3,100 


2,600 


2,100 


-40° 


39.8 


80 


2,300 


1,900 


1,600 



SunEarth Inc. 


-50° 


65.7 


80 


3,200 


2,900 


2,400 


-60° 


65.7 


80 


3,500 


3,200 


2,600 


-60° 


65.7 


80 


3,500 


3,000 


2,400 


-60° 


65.7 


80 


3,400 


3,100 


2,500 


-60° 


81.7 


120 


3,600 


3,400 


2,800 


-60° 


81.7 


120 


3,400 


3,300 


2,700 


-60° 


81.7 


120 


3,700 


3,300 


2,600 


-60° 


81.7 


120 


3,600 


3,300 


2,700 



Synergy Solar 


-50° 


39.6 


80 


2,700 


2,200 


1,800 


-50° 


53.4 


80 


3,100 


2,600 


2,100 


-50° 


53.4 


80 


3,000 


2,600 


2,100 


-50° 


59.4 


80 


3,000 


2,700 


2,200 


-50° 


53.4 


80 


2,700 


2,300 


1,900 



Thermomax 
Industries Ltd 


-60° 


65.9 


80 


3,200 


2,900 


2,300 


-60° 


82.2 


120 


3,400 


3,100 


2,500 


-60° 


98.6 


120 


3,500 


3,400 


2,700 


-50° 


92.1 


120 


3,400 


3,100 


2,500 


-50° 


92.1 


80 


3,400 


3,100 


2,500 


-50° 


107.4 


120 


3,500 


3,300 


2,600 




Trendsetter 

Industries 


-20° 


81.7 


120 


2,800 


2,500 


2,100 



lOO 



home power 125 /june & july 2008 




certified solar 



System Name 


System Model 


System Type 


Collector Model 


Aux. Tank 
Size (Gal.) 


Fluid 


Controller 


Supply-Side 
Heat Exchanger 


Premium Package 


Premium II-80E 




Schuco - V, H, LA 








Tank Wraparound 


Premium III-120E 


Indirect Forced 
Circulation - 
Antifreeze 


Schuco - V, H, LA 


None 


Glycol 


Differential 


Heat Exchanger 
with a Double Wall 
and Positive Leak 


Slimline Package 


Slimline II-80E 


Schuco - V, LA 


Controller 


Slimline III-120E 




Schuco - V, LA 








Detection 





D2B-12009120 




Solar Energy - SE-40 












D2B-12009120 




Alternate Energy Tech. 
- AE-40 








Shell-and-Tube Heat 


Duro-Drainback 


D2B-12009-96 


Indirect Forced 


Alternate Energy Tech. 
- AE-32 






Differential 

Controller 


Exchanger 


Solar Water Heating 
System 


D2B-12009-96 


Circulation - 
Drainback 


SunEarth - EP-32 


None 


Water 




D2B-8009-63 


Solar Energy - SE-21 












D2B-8009-80 




Solar Energy - SE-40 








Tank Wraparound 




D2B-8009-80 




Alternate Energy Tech. 
- AE-40 








Heat Exchanger 





Solvelox DB 


S-SV-DB100 


Indirect Forced 
Circulation - 
Drainback 


Solene - SLCR-32 


None 


Water 


Differential 

Controller 


Plate Heat Exchanger 
with a Single Wall 


S-SV-DB100 


Heliodyne - 408 000 





Solene/Chromagen 
DC Closed Loop 


SLCR60DC-80HE 


Indirect Forced 
Circulation - 
Antifreeze 


Solene - SLCR-30 


None 


Glycol 


Differential 

Controller 


Tank Wraparound 
Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 


SLCR64DC-80HE 


Solene - SLCR-32 


Solene/Corona DC 
Closed Loop 


SLCO64DC-80HE 


Indirect Forced 
Circulation - 
Drainback 


Solene - SLCO-32 


Water 


SLC080DC-80HE 


Solene - SLCO-40 


SLC080DC-80HE-XE 


Solene - SLCO-40 


50 


Solene/Corona 

Drainback 


SLCO64DC-80DB 


Solene - SLCO-32 


None 


SLC080DC-80DB 


Solene - SLCO-40 



Sup.plen.ergy Solar 
Water Heater 



SESI-120-80 



SESI-80-40 



Indirect Forced 
Circulation - 
Antifreeze 



Alternate Energy Tech. 
- AE-40 



Alternate Energy Tech. 
- AE-40 



None 



Glycol 



PV Panel 
Controller 



Tank Wraparound 
Heat Exchanger with 
a Double Wall 



Cascade 


ECRD-64-80 


Indirect Forced 
Circulation - 
Drainback 


SunEarth - EC-32 


None 


Water 


Differential 

Controller 


Solaray 


TE64C-80-1 


Indirect Forced 
Circulation - 
Antifreeze 


SunEarth - EC-32 


Glycol 


TE64C-80-PV 


SunEarth - EC-32 


PV Panel 
Controller 


TE64P-80-1 


SunEarth - EP-32 


Differential 

Controller 


TE80C-120-1 


SunEarth - EC-40 


TE80C-120-2 


SunEarth - EC-40 


50 


TE80C-120-PV 


SunEarth - EC-40 


None 


PV Panel 
Controller 


TE80P-120-1 


SunEarth - EP-40 


Differential 

Controller 



Tank Wraparound 
Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 





40-1T 




Synergy - TC-19.78 


None 








Drainback 
Stainless HX 


53- IT 


Indirect Forced 


Synergy - TC-26.52 




Differential 

Controller 


Plate Heat Exchanger 
with a Single Wall 


53-2T 


Circulation - 


Synergy - TC-26.52 


50 


Water 


60-2T 


Drainback 


Synergy - TC-19.78 


50 






S53-2T 




Synergy - S26.68 


50 











Mazdon 40-R80 




Thermo Tech. - 
TMA-600-20 










Thermomax 

Mazdon 


Mazdon 50-R120 


Indirect Forced 
Circulation - 
Antifreeze 


Thermo Tech. - 
TMA-600-50 








Tank Wraparound 
Heat Exchanger 
with a Double Wall 
and Positive Leak 
Detection 




Mazdon 60-R120 


Thermo Tech. - 
TMA-600-30 


None 


Glycol 


Differential 

Controller 


Thermomax 

Solamax 


Solamax 60R-R120 


Thermo Tech. - AST30 








Solamax 60R-R80 




Thermo Tech. - AST30 










Solamax 70R-R120 




Thermo Tech. - AST70 











Six Rivers Solar 


SRS-100-2-40-PC-E 


Indirect Forced 
Circulation - 
Drainback 


SunEarth - SP-40 


50 


Water 


Differential 

Controller 


None 



www.homepower.corn 



101 



HARSH CLIMATE SYSTEMS 




certified solar 



Certification for 
Tax Credit Eligibility? 

Unless federal tax credits for SHW systems are extended, 
this may be the last year you can take advantage of 
Uncle Sam by installing a solar hot water system. Under 
the existing federal tax credit law, owners of new SHW 
installations are eligible for a tax credit of up to $2,000. 
But when it comes to what kind of certification is required 
to receive a break from the Feds, the waters are muddy. 
The law states that "the property" of residential solar 
water heaters must be certified by the SRCC, but it's 
unclear whether this refers to the collector or the whole 
system. 

While we aren't aware of anyone being denied the 
federal tax credit from basing their claim on the OG-100 
standard, some states and utility districts are requiring 
OG-300 ratingsto be eligiblefortheir incentives, including 
Arizona; California — Sacramento Municipal Utility District 
and City of Thousand Oaks; Colorado; Illinois; Nevada — 
Public Utilities Commission; and Oregon — Eugene Water 
and Electric Board and the City of Ashland. 



System Selection Considerations 

Once you've classified your climate, you can determine 
what system is right for your site. What's best? If you live 
in a freezing climate — or in a milder climate but just want to 
hedge your bets, use a drainback or antifreeze closed-loop 
system. If it doesn't freeze, or freezes are rare and mild, one 
of three "mild-climate" systems can fit your needs. Passive 
or active, PV or AC powered, these choices are up to you. 
Systems with quality components should have decades of 
good performance. 

Access 

Contributing editor Chuck Marken (chuck.marken@homepower.com) 
is a New Mexico-licensed plumber, electrician, and heating and air 
conditioning contractor. He has been installing and servicing solar 
thermal systems since 1979. Chuck is a part-time instructor for Solar 
Energy International and the University of New Mexico. 

Home Power Data Manager Doug Puffer (doug.puffer@homepower. 
com) holds a master's degree in Environmental Studies from Clark 
University and an associate's degree in software engineering. He has 
installed solar hot water systems and worked in other areas of the RE 
industry. 

Solar Rating & Certification Corp. • www.solar-rating.org 




HaRruess the 

PQUUtM 



www. u om 

|>h SOD-6 9 5-0 5 A 5 



U S Ropery offers lh& perfecf s-olufion for off of 

your ollcrn ci rive energy sforogc requirement. 

^ EXTREME CAPACITY 
v EXTREME LIFE 
c EXTREME POWER 



home power 125 /june & july 2008 






© f % p p @ r 




1 1 ^ \i W7 1 1 



r 


N 


^ * 


■F 



Modified Sine Wave 
Inverters 



Light Duty 
Pure Sine Wave 
Inverters 



Samlex America Power Conversion Solutions are available through: 



Commercial Grade 
Pure Sine Wave 
Inverters 



EKXTER3 





Muti Stage 
Battery Chargers 



StepUp/Step Down 
DC-DC Converters 



NEW BATTERY MONITOR 



Uk 






rn 



i t - h k <> i ■ 



www.samlexamerica.com 



Get Solar Access and Shading Data On-Site 
with the Touch of a Button. 




The Solmetric SunEye™ 
is all you need. 



• Integrated fish-eye lens and digital camera 

• Captures image of obstructions and 
superimposes sunpaths 

• Works anywhere in the world 

• Accounts for panel tilt and orientation 

• Simulates removal of shade-causing obstructions 

• Generates reports and archives data 




To purchase, contact 1-800-967-6917 
or www.dcpower-systems.com 




Solmetric 

w.solmetric.com 




GPS Add-on: 

• Automatically detects location for each Skyline 

• Compatible with new and existing SunEye units 





m 



Energy Efficient. 
B Jmi a 



Available in 1 2/24V DC or new 1 20V AC 






FEATURES: 



3 [F^aaajoa^ 
5 






www.homepower.corn 






'a WA Wa 



FEATURING: 



tpCI i h [j !]rHTiT&i 

Serving the Solar Industry Since 1 979 





Also Featuring: 

SUN AIRE 




Liquid Collectors 
for Solar Hot Water 
& Radiant Floor Systems 



Other Solar H 2 0 
Products & Parts 

• Pumps 

• Heat Exchangers 

• Storage Tanks 

• Complete Systems 

• Controls 

• Batch Water Heaters 



d i Ft-Ti-n- 






Air Collectors 
for Home Heating 




Other Solar Hot Air 
Products & Parts 

• Blowers 

• Backdraft Dampers 

• Controls 

• DIY Systems 



l BOO | 345-0311 • www.aaasalar.cam • salarstuff@aaasalar.cam 



2021 ZearingNW, Albuquerque, NM8701 4 



ELECTRO AUTOMOTIVE 

Electric Car Conversions Since 1979 
Books Videos ^=^Kits Components 

Catalog Send $6.00 for our catalog, or visit our web site. 

"Convert It" We wrote the book on electric car conversions - literally! 
Send $30.00 postage paid for this hands-on how-to conversion manual, 
written in plain English for the home hobbyist mechanic. 

Conversion Kits Complete custom bolt-in kits for the VW Rabbit 
and Porsche 914, or a universal kit for other small cars and light trucks. 

Web Site Visit our web site for our complete catalog, price list, 
gallery of conversions, and extensive conversion information section. 

P.0 Box 1113-HP, Felton, CA 95018-1113 -=<^>^831-429-1989 
WWW.ELECTROAUTO.COM -<^n>^ELECTRO@CRUZIO.COM 




104 



home power 125 /june & july 2008 





www.homepower.corn 







Not 



to Fuse? 

by John Wiles 

Sponsored by the U.S. Department of Energy 



Most people agree that the National Electrical Code (NEC) 
improves with each edition. However, photovoltaic technology 
is still evolving, with new equipment, new wiring procedures, 
and new installation requirements being developed constantly. 
With these changes, and more inspectors and installers coming 
into the field every day, questions are bound to arise. 

Some procedures and best approaches continue to stump 
both old timers and newcomers alike. The question of when 
to use overcurrent devices, such as fuses or circuit breakers, 
in direct-current circuits between PV modules and utility- 
interactive inverters is one in particular that plagues PV pros, 
since the solution is not directly found in the NEC but must 
be evaluated on a case-by-case basis. 

Before answering this question, we first should address 
the issue that properly rated fuses and circuit breakers are 
functionally equivalent for this application, and are collectively 
known as overcurrent protective devices (OCPDs). This is 
true even though the required label on the back of certified/ 
listed PV modules says "fuse." 

In general, PV arrays operating at DC voltages above 
150 volts (cold-weather, open-circuit voltage) may use fuses, 
and those operating below this voltage may use either fuses 
or circuit breakers. These applications are due to the ratings, 
availability, and cost of the different devices. 

Protecting the Conductor 

The NEC requires that, in most electrical systems, every 
ungrounded circuit conductor be protected from overcurrent 
that might damage that conductor. OCPDs provide that 
function. However, smaller utility-interactive PV systems 
may not need OCPDs in the DC circuits connected to the PV 
modules. 

PV modules are current-limited devices, and their 
worst-case, continuous outputs, according to NEC Section 
690.8(A)(1), are 1.25 times the rated short-circuit current 
(Isc). An exception in Section 690.9(A) allows conductors 
(typically rated at 1.56 times Isc) to be used with no OCPD 
where there are no sources of external currents that might 
damage that conductor. 

However, if there are external sources of current that 
can potentially damage the internal module conductors. 
Underwriters Laboratories (UL), in its safety standard for 
modules (UL Standard 1703), has established that modules 
must have an external series OCPD. The NEC outlines 



^ WARNING 

r, * a * 

u mf h' r ■ ■ * "■* 

1 *v-n. LLLv IL 

CO NOT TOUfr TEBM4L5. 




* n 



■ — mmm mm 


ce ED 


mu 


kcso 


m HD. 


0065100*92 




DATE 1 


2000.6 




iFPWAKf 1 
WO ttU 
TFj^BUTlHE 


Ml 1 E 
p C 


^TT.h 

AT 4 C 


iw.tn mr 




eow 


se w 




VTMx 


16 . sv 


15,2 V 


7 d 




4. 73A 


3,33 A 




ITc-t 


at, sv 


- - - 


_ a, 0 kol 


IH 


4, 97ft 


- - - 








FIELD VIRIW 

uimii 1 1 -■ 

*f I. JF|| FJi || I 



rinr flAT i mg. 






eg KyncERa 

Hbdf r iirib 



mm iM'ituiiiniw 



This PV module label states the maximum series fuse size. 



protection for the wire, while the UL standard addresses 
protecting the module. Without an OCPD, the module can be 
damaged if reverse currents are forced through the module 
(due to an external or internal fault) in excess of the values of 
the maximum series fuse marked on the label on the back of 
the module. 

External sources of current vary from system to system. 
They can originate from modules or module strings paralleled 
to the module of interest; from batteries backfeeding through 
charge controllers; or from utility currents backfeeding 
through utility-interactive inverters. (Note that the scenarios 
discussed below apply only to batteryless, utility-interactive 
PV systems.) 



106 



home power 125 /June & july 2008 





code corner 




Utility- Interactive Inverters & 

Utility Backfeed Currents 

Most smaller utility-interactive inverters (10 KW or less) 
are designed so that they cannot backfeed current from the 
utility into array faults. These inverters have a maximum 
utility backfeed current of 0 amps. Although tests for 
abnormal operation and backfeeding exist, these tests do 
not rule out possible backfeed during an inverter's normal 
operation. Certification, usually in the form of a technical 
bulletin or technical specifications from the manufacturer, 
that the inverter cannot backfeed into an array fault under 
normal operation should be obtained from the inverter's 
manufacturer. 

If the inverter can backfeed utility currents into the DC 
PV wiring, the NEC requires that an OCPD be installed in 
series with the output of all strings (or modules) to protect the 
cables and the modules from reverse currents. Inverters that 
have a maximum utility backfeed of something other than 
0 A may be inverters larger than 10 KW or those designed for 
transformerless or bipolar operation. In cases where there are 
fused combiner boxes mounted at the array, an OCPD may 
also be needed at the inverter input, since the inverter can 
be a potential source of overcurrent. This OCPD will have a 
minimum rating based on the number of strings connected 
in parallel on that circuit and the short-circuit current of 
each string. This OCPD is sized to allow maximum forward 
currents from the array (all strings of modules) to pass 
through without interruption and to keep the overcurrent 
device from operating at more than 80% of rating. 



Faults & Parallel Strings 

The most common backfeed situation occurs in systems where 
there are multiple strings of modules connected in parallel. In 
the event of a fault, nonfaulted strings may be able to supply 
sufficient overcurrents (through the parallel connection) to 
damage either the conductors or the modules in the faulted 
strings. The inverter, for this example, has not contributed to 
the fault currents. 

Fault currents can increase the normal current being 
carried in wires and modules. So the basic question becomes: 
How many PV modules or strings of modules can be 
connected in parallel and still meet NEC and UL requirements 
(marked on the back of each module) before an OCPD is 
needed on each module or string of modules? 

UL requirements marked on the modules are based on the 
reverse-current tests described, which stipulate a maximum 
value for the OCPD. Section 110.3B of the NEC requires that 
installers follow the manufacturer's instructions and labels. 
However, lesser values can be used as long as they meet the 
NEC requirement of being 1.56 times the module short-circuit 
current (1.56 Isc) to protect the conductor associated with the 
module or string of modules (Section 690. 8 A and B). 

In a few cases, module manufacturers have not met 
the code requirements, and the value of the module OCPD 
marked on the back of the module is less than 1.56 Isc. This 
poses a code conflict (110.3(B) vs. 690.8,9) and is an issue for 
UL to rectify. 



www. homepower . com 



107 




corner 



String Scenarios 

Assuming batteryless grid-intertie with an inverter that is 
certified not to backfeed via the AC source, let's examine 
some scenarios. 

One string of modules. In a one-string system, no fusing 
would be required because no external sources of overcurrent 
exist. An unfused DC PV disconnect would be used on 
this type of system. The maximum series fuse rating that is 
marked on the back of the module is at least 1.56 Isc, and 
there are no sources of external currents that could damage 
the modules or the connecting cables (also rated at 1.56 Isc 
or higher). 

Now let's look at a PV system with multiple strings of 
modules connected in parallel. Keep in mind that we are not 
determining the rating of any required OCPD; we are merely 
making some calculations that determine whether or not an 
OCPD is needed on each string of modules. 

Two strings in parallel. Consider two modules or two 
strings of modules connected in parallel, then connected to the 
inverter input. Each string of modules can generate a maximum 
of 1.25 Isc. If a fault occurs in one string, the second unfaulted 
string can try to force 1.25 Isc amps into the faulted string. 
However, the modules in the faulted string can withstand 
currents up to at least 1.56 Isc or higher (if their marked series 
fuse rating is higher), and the conductors have an ampacity of 
at least 1.56 Isc or greater. Therefore, with only two strings of 
modules, no currents exist in the PV array that can damage the 
modules or the wiring — and no OCPDs are required. 

Three strings in parallel. Now consider a system with 
three strings of modules connected in parallel. A fault in one 
string could see currents from the two other unfaulted strings. 
Each of these unfaulted strings could deliver up to 1.25 Isc 
under worst-case conditions for a total of 2.5 Isc (2 x 1.25 Isc). 
Suppose that the module manufacturer had the value of the 
maximum series fuse marked on the back of the module of 
exactly 1.56 Isc and the wiring was sized at exactly 1.56 Isc. 
The currents from the two unfaulted strings at 2.5 Isc would 
be far greater than the series fuse rating of the module and 
the ampacity of the conductors, risking damage. In this case, 
fuses in all three strings at a minimum value of 1.56 Isc would 
be required. 

However, module manufacturers usually do not specify 
a marked maximum fuse value of exactly 1.56 Isc. Typically, 
the module will pass the UL reverse-current tests at a higher 
current, such as 15 amps. As an example, let's take a module 
that has an Isc of 5 amps and a marked value of the maximum 
series fuse of 15 amps. To protect the conductors, the 
interconnecting conductors between the modules must also 
have an ampacity of 15 amps, after the appropriate derating 
for conditions of use have been applied. In a system with 
three series strings of this module, the two unfaulted strings 
could deliver 12.5 amps (2 x 1.25 x 5). Since this current is less 
than the 15-amp ampacity of the conductors and is also less 
than the 15-amp maximum series fuse requirement marked 
on the back of the module, no fuses are required because no 
damage can be caused by overcurrent. The actual conductor 
ampacity would not have to be 15 amps but would have to be 
at least 12.5 amps after derating for conditions of use. 



Determining Fuse 
Requirements 




In another example, let's look at a module rating of 8 amps 
Isc with the module wiring and module fuse rating still at 15 
amps. The two unfaulted strings could send up to 20 amps (2 
x 8 x 1.25). Because this exceeds the conductor ampacity and 
the ability of the module to withstand reverse currents, fuses 
would be required in each string of modules. The OCPD must 
be at least 1.56 Isc — in this case, 12.48 amps (1.56 x 8) and 
not more than 15 amps. A 15-amp OCPD would normally be 
used. 

Modules with low Isc and high series fuse ratings. 

Some modules have a low short-circuit current and a high 
maximum series fuse rating. A module with a 1.5-amp Isc and 
a 20-amp maximum series fuse can have up to 11 strings of 
modules in parallel without any OCPD. 

The bottom line is that when more than two modules or 
strings of modules are connected in parallel, a calculation 
should be done to see if an OCPD is required in each string. 
When three strings of modules are connected in parallel 
without fuses, the conductor ampacity may have to be greater 
than the normal 1.56 Isc, as described in NEC 690.9(A), 
exception (b). For a slightly more technical approach to these 
requirements and calculations, see Appendix J in PV Power 
Systems and the 2005 NEC: Suggested Practices manual (see 
Access). 

Access 

John Wiles (jwiles@nmsu.edu) works at the Institute for Energy 
and the Environment, which provides engineering support to the 
PV industry and a focal point for code issues related to PV systems. 
As an old solar pioneer, he lived for 16 years in a stand-alone PV- 
powered home — permitted and inspected, of course. This work 
was supported by the United States Department of Energy under 
contract DE-FC 36-05-G01 5149. 

Photovoltaic Power Systems and the 2005 National Electrical 
Code: Suggested Practices by John Wiles • www.nmsu.edu/~tdi/ 
Photovoltaics/Codes-Stds/PVnecSug Pract.html 

PV Systems Inspector/Installer Checklist and previous Code Corner 
articles • www.nmsu.edu/~tdi/Photovoltaics/Codes-Stds/Codes- 
Stds.html 




home power 125 /June & july 2008 



1 ^ 



SOLAR 



an SC Solar Company 

Toll-Free 

866 - 856-9819 

innovativesolar.com 




Expert Solar Design, 

Unsurpassed Customer Service 

Whether you are looking for a solar system to power your entire 
home, or a small system to provide back-up during a power 
outage, the sales and design team at Innovative Solar Solutions 
brings the experience and commitment to service that instill 
confidence in our customers. 

■ Solar Water Pumping Systems 

■ Inverters, Charge Controllers and Batteries 

■ Large Selection of Solar Panels 

■ Complete Systems - Grid Tied & Off Grid Systems 

2725 WESTINGHOUSE BLVD., SUITE 100, CHARLOTTE, NC 28273 




H Inc. | Phone (909) 434-31 00 | www.sunearthinc.com 



yfeca 



With Steca's 
Temperature Differential 
Controllers. 

TR 0301 U 

■ Digital acojgQ^ 

■ Lighted animated^CD display 

■ 3 sensor inputs / 1 ’fused 
1 20 V AC output 

■ Freeze recirculation functions 

■ Vacation overheat protection I 



yieca 






Hot water 
from the sun. 








A&C Green Energy has been 
serving the alternative energy 
industry for years. In today’s 
society where energy demand 
is increasing, more attention 
is being paid to the environment 
and the value of clean energy. 
We offer complete wind turbine 
systems from 500 W to 20 kW 
as well as solar panels. 

Wind turbine systems 
• Solar panels 
• Site Assessment 
Installation & Services f'lv. 

Toll Free! 866-WNDPWR-3 

or 866-963-7973 ■ 

PO Box 941122, Plano, TX 75074 
sales@acgreenenergy.com www.acgreenenergy.com 






Wind Turbine DIY Materials 

j-p 




Blades & Hub 
Magnets 
Magnet Wire 
■*~ 4 *eries 



CMS Magnetics has been selling commercial wind generator parts for 
years. Our customers require quality, durability, and efficiency. This is 
why CMS Magnetics is at the top of the small wind generator industry. 
Our powerful neodymium magnets are licensed and include a triple 
layer of coating for added protection. All magnet wire is top quality 
Essex/REAand made in the USA. 



www.homepower.corn 



109 











SOUR HOr HATER SVSTEJHS (3^ 

Self-PrzssuriHf}, Antsfrseie Closed 





CLEAN: Ro^ucoCQj 6 y 2.500 lb* 
P«r Year {"Driving • SrnaH Car) 
AFFORDABLE 1 * Sl.OOmwrm or 
SO.Q^fcWh 



CHJtt 



Year Wjrrjcity. FttJEx Ground . D-l-Y Mj i"uj-I 

ww w. h utfe rs u n so I uti ons .co rn 
(856)259*6895 



Mu*! 












SOLAR WAND SYSTEMS ARE: 




Electricity From the Sun 



Solar Electric Utility Tie 

- .. 

Remote Homes, Water Pumping, RVs 
and Telecommunication Systems. 

Call one of our 
Solar Design. Technicians to 
help design the right system for you. 

m-m 



Come in and visit us 
at our NEW 



AOm E 



> 7 . 




The BEST Tool for Solar Site Analysis 

JUST SOT SETTER! 



Solar 

ASSISTANT 



RAJSING THE STANDARD IN SOLAR SITE ANALYSIS 



3953 Marsh Creek Road, Linden, TN 37096 • 317-501-2529 • Fax 931-589-5400 
info@solarpathfinder.com • www.solarpathfinder.com 



Now, the NEW Solar Pathfinder 
Assistant software, and 
your digital camera, carry 
that shading information 
into a concise, thorough, 
professional-looking solar site 
analysis report in just seconds. 

Solar Pathfinder Assistant: 

automatically adjusts for magnetic 
declination, latitude, azimuth, tilt angle, & 
tracking mode (fixed, 1-axis, 2 axis); 
automatically does yearly energy computations using included NREL data 
(no internet connection necessary); displays “before /after” results of 
removing obstructions; and creates professional-looking reports! 



The original Solar Pathfinder 

with its reflective properties 
gives an excellent “instant solar 
blueprint” of the prospective site. 



AUTOMAGIC BATTERY WATERING 




WE MAKE WATER PROM YOUR GAS 



HvdTOtn tKHSu r y causally nKombr-fld mIg-p.'g 

w 3rd srtw rod to c^ch z^Hory tel . Hoops Brti-zrv tapped rtf tor 
PdOcoded periods rt ton* and- r-educw rrw fiiorvnce certs Esftesrve 
M : W" jas STOluaHy elunraflffi] \\m the kaJlery mm Gwrraw 
way ard fumes Me remained rd washed bac k i n : «:■ each briery oei 
Ekctrrt^e ^ tw*go r . raClendlng fr* usrtu! pewe# ar»d Ha of Iho 
ballery. HYDBOCAP leptac-fl bLaJierye Baflnry 

msinlen-r-ze ri isdu-ied Wme & cal bf rmne rformaHon- 





305^696-2504 
975 MW 95 Si 
Miami FL 33150 



IIO 



home power 125 /june & july 2008 






NEW BOOKS TO 





OURC1 



DO-IT-YOURSELF 



£ if i 



BOOKS TO WALK THE TALK 

New Society Publishers 

WWW.NEWSOCIETY.COM 1 800 567 6772 



/soli 



solarHOt 



MAKING SOLAR MAKE SENSE 



Manufacturing efficient, innovative 
and easy to install solar heating 
solutions for residential, commercial 
and pool applications. 



SOLVE LOl 
EFF«m 



urv'iw f U nH ■ top ibIkI 
5 IMX iw Iwnul fc-fiam 



wwv*,«4a rNrtvs?i .cwn 



Ecopreneuring 

Putting Purpose and the 
Planet Before Profits 

John Ivanko and Lisa Kivirist 

How to grow your own green 
business from the ground up! 

$17.95 



HOW TO BUILD 
WITH GRID BEAM 

A Fast , Easy and Affordable 
System for Constructing 
Almost Anything 

Phil Jergenson, 

Richard Jergenson, 

Wilma Keppel 

Build almost anything! 

$29.95 



c L . L^innpi 



SOLAtf 



Living 



svo 



Powering Your Vehicle 
with Straight Vegetable Oil 



Forest Gregg 



Real Goods 
Solar living 
Sourcebook 

Special 30th 

ANNIVERSARY EDITION 

The Complete Guide to 
Renewable Energy 
Technologies and 
Sustainable Living 



John Schaeffer 



Fuel your diesel engine 
with vegetable oil! 



The essential renewable 
energy resource, completely 
revised and updated for 2008 

$35.00 



User Friendly Hydro Power 



Repair Service 
Parts 

Upgraded Parts 

for many Homescale Hydros including 
Harris, ES&D, Windstream, Little Spokane, 
and others. 

Alternative Power & Machine 



4040 Highland Ave. Unit #H • Grants Pass, OR 97526 

541 - 476-8916 

altpower@grantspass.com 

www.apmhydro.com 



www.homepower.corn 



111 









independent power providers 

Protecting the 
Interests of PV Pros 

by Don Loweburg 



The vast majority of PV pros — both the newcomers and 
the tried-and-true pioneers who have helped shape the 
industry — recognize the need for a trade organization to 
protect and support their interests. These men and women 
have helped the business grow into the mainstream industry 
that it is becoming today, and their position in the industry's 
continued evolution should be maintained. The question is: 
What trade group can step up to meet this need? Maybe it is 
time to reinvigorate this column's namesake organization, the 
Independent Power Providers. 

In 1993, the Renewable Energy Development Institute 
(REDI) held a conference in Willi ts, California. The purpose of 
the conference was to explore various approaches and plans 
for commercializing PV. Attending the conference were utility 
personnel, state regulators, PV industry representatives. Home 
Power magazine staff, and solar installers. One intent of the 
conference was to discuss PV commercialization proposals 
funded by the U.S. Department of Energy (DOE) and the 
Utility Photovoltaic Group (UPVG), a consortium of utilities 
interested in pursuing PV as a utility-service option. 

The basic premise held by UPVG and some within the PV 
industry was that utilities would be the natural market for 
the commercialization of PV. To this end, the utilities — with 
the assistance of UPVG and financial assistance from the 
DOE — would aggregate projects and execute bulk buys from 
PV manufacturers. It was assumed that the utilities would 
be a volume market and, over time, drive down the price of 
PV for all customers. Using this model of "sustained orderly 
development," PV manufacturers would be able to expand 
production to meet the needs of all players in a predictable, 
growing utility market. 

UPVG's commercialization plan was to first focus on 
off-grid applications as a means of familiarizing utilities 
with PV. It was understood that this market itself would be 
insufficient to bring PV to economic parity with grid power, 
but would be a first step — to be followed later with the 
commercialization of grid-connected PV systems. UPVG's 
plan was that regulated utilities would offer PV systems or 
services for sale to off-gridders as a means to bring them into 
the utilities' rate base. 

This proposal did not sit well with two groups attending the 
REDI conference. First, California state regulators pointed out 
a possible conflict with California Public Utility Code 2775.5, 
which would "deny the authorization sought (by an electric 
corporation) if it finds that the proposed program will restrict 
competition or restrict growth in the solar energy industry." 



Further, the statute stipulated that proposed authorization 
would only be granted for a program that "would accelerate 
the development and use of solar energy systems." 

The second group opposed to the UPVG proposal was 
existing PV installers. Fifteen years ago, the market for PV was 
primarily off grid and installers saw no benefit to themselves 
if utilities were to enter the PV installation business — in 
fact, many of them viewed it as giving the utilities an unfair 
advantage within their own industry. 

Preserving the Pros’ Perspective 

A majority of installers at the conference were adamant 
in their opposition and decided to form a formal group to 
represent their interests. Independent Power Providers (IPP) 
was incorporated as a nonprofit public benefit corporation in 
California on September 30, 1994, to "promote and encourage 
the use of renewable energy by developing opportunities for 
end-user ownership of renewable energy generation sources 
and encouraging a professional installation infrastructure..." 

That same year. Southern California Edison (SCE), one of 
the three major California-regulated electric utilities, proposed 
to market PV systems to off-grid customers in keeping with 
UPVG's strategy to commercialize high-value applications 
first. To do so, SCE sought permission from the California 
Public Utilities Commission (CPUC) via an "advice letter" 
(AL), which is intended to be used only for minor changes 
in already-in-place policy. SCE framed their plan as an 
experimental, three-year pilot program. 

IPP responded to the AL, protesting the plan. Specifically, 
IPP asserted that SCE's sale of off-grid systems would not 
only restrict competition but also restrict the development 
and use of PV systems in the state. The response also pointed 
out that about 20 existing PV companies in California already 
specialized in the installation of off-grid systems. IPP also 
questioned the need and legality of a regulated utility entering 
an already-competitive market for PV installation. 

IPP's protest resulted in limited success. The CPUC 
issued a stipulated decision, allowing SCE to market off- 
grid systems but requiring them to bid the jobs out to PV 
contractors. Additionally, the regulators required SCE to 
hold semiannual public meetings at which the progress of the 
program would be evaluated. Within these meetings, it was 
understood that SCE needed to show two things: that their 
program was not restricting competition or restricting growth 
in the solar industry, and that their program was accelerating 
the development and use of solar energy systems. 



home power 125 /June & july 2008 



independent power providers 



IPP’s Solar 
Scorecard 

IPP's action over the past 15 years has strongly 

influenced many aspects of the PV industry and market. 

Here's a sampling of the stances that IPP has taken: 

• Opposed utility ownership of PV resources on 
customer sites. 

• Supported net metering in California and 
nationally. 

• Supported rebates and incentives going directly to 
the customer. 

• Supported simplified interconnection to the utility. 

• Opposed unnecessary extra disconnects. (California's 
PG&E finally dropped that requirement in 2007.) 

• Opposed the levy of "standby" and "demand" 
charges by California utilities on net-metered 
systems. 

• Supported customer ownership of renewable energy 
credits (RECs). 



At the second REDI conference in 1995, as a rebuttal to 
the UPVG plan, IPP presented its own commercialization 
plan. The IPP plan included net metering, simplified utility 
interconnection rules, rebates delivered to the customer, 
UL standards and ratings for equipment, and standards for 
installers. IPP and other organizations continued to promote 
the ideas central to its plan, eventually resulting in some of 
the earliest commercialization regulations and incentives in 
the nation (see "IPP's Solar Scorecard" sidebar). 

The second phase of the UPVG commercialization plan 
was the development of home-scale, grid-connected projects. 
Once again, IPP led the opposition when SCE stated its desire 
to pursue grid-tied systems as a customer sales option. The 
result was that IPP and SCE negotiated an agreement that IPP 
would not protest if SCE pursued an experimental grid-tied 
PV program structured like the off-grid program. 

Overall, only a few off-grid and grid-connected systems 
were sold by SCE, and both programs were discontinued 
mainly because they were not economical for the company. 



As IPP installers had long asserted, the utility's involvement 
resulted in higher-cost PV systems — which few customers 
could afford. 

During the late 1990s, California utilities underwent 
restructuring. Given the minimal success of SCE's PV 
programs and the overwhelming organizational demands 
of restructuring, utility PV commercialization efforts faded. 
In 1996, the California legislature created a net metering 
law; in 1998, it established a customer rebate program. 
The new consensus held in the industry was that on-site, 
customer-owned (or third-party-owned) PV would be the 
commercialization pathway — the model that remains today. 

What’s Next? 

Veteran Virginia PV-pioneer Jeffrey Yago said in a recent 
forum message, "We are dealing with many common issues, 
like the lack of response from manufacturers when they 
discontinue products we really need, or code groups that 
listen and then go on and do what they want, and states 
that make rules right out of never-never land. However, a 
single voice is just not being heard, and it is getting worse 
as everything gets passed down to us in a take-it-or-leave-it 
dictate." 

Central to the creation of IPP was the need to give voice 
and status to PV pioneers whose interests — and livelihoods — 
were being threatened as regulated utilities attempted to take 
over the market. While IPP has served its original mission, 
many valuable projects, purposes, and installer issues still 
remain. Professional installers frequently cite the need for 
a trade association to tackle such issues, but none have 
been able to step forward to organize it. Can IPP be that 
organization? The answer really depends on whether there is 
sufficient interest and energy to make it so. The current IPP 
board is eager to facilitate any such transition. 

Access 

Don Loweburg (don.loweburg@homepower.com) is a solar pioneer 
in central California. He owns and operates Offline Independent 
Energy Systems, and sits on the boards of the California Solar Energy 
Industries Association and the North American Board of Certified 
Energy Practitioners (NABCEP). 



Break Free From the Pump 



Enjoy the freedom of driving electric. 
Join the EAA today and declare your 
independence from 
high gas prices 
and imported oil. 



ELECTRIC AUTO ASSOCIATION 

For more information 
visit us at eaaev.org 







Finding a Green Energy Job 
Just Got Easier 



"This book is a gem. I highly 
recommend it!" - Susan Schleith, 
Florida Solar Energy Center 



NEW! Careers in Renewable Energy 
by Gregory McNamee $ 20.00 
www.PixyJackPress.com 

call 303.810.2850 
PixyJack Press • PO Box 149 
Masonville, CO 80541 



www.homepower.corn 



113 




INTER NATIONAL 



XC3 Solar Modules 




High Quality Modules and Controllers 

“This is quite a well built 85 watt panel, I am impressed. Quality 
angle Aluminum; very rigid construction. ” 

Orval Snyder Northwest Power CO, LLC 



Distributed by: 

Affordable Solar www.affordable-solar.com 
Telephone: 1-800 810 9939 

Please quote the special offer code "XC3" for preferential pricing. 



www.xc3solar.com 





Oziiiiorti® 



Our 21st Year Offgrid! 

We provide excellent service & technical support. 
Residential Power • Water Systems • Communications 
Wind • PV • Hydro • Custom Design • Installation 
All Major Brands 



OFF LINE 

Located in the central Sierra, near Yosemite 

e-mail: ofln@aol.com 
www.psnw.com/~ofln 
P.O. Box 231, North Fork, CA 93643 

m (559) 877-7080 

CA Lie. #661052 



IE BE 

s. 1 ' »: 

MEMBER 




et more energy from your system 
Rated. for use with PV input up to 96 
Vocjn 12/24V 
Stand-Alone 
Systems 
20A Charge 



O 

ohccos 



Efficient MPPT 

Ready for use in 
Stand-Alone Systems 



Phocos USA 742 E. 46th Street Tucson, AZ 85713 USA 

Phone :+1 (520) 777-7906 Fax:+1 (520) 844-6316 info-usa@phocos.com 



Germany China ■ India Bolivia Bangladesh Australia Brazil 
Kenya Mongolia Romania Singapore South Africa Tunisia USA 



www.phocos.com 





Quality Solar Energy Products 



THINK THERMAL- 
THINK SUNEARTH 




The Empire Series Liquid Flat Plate Collector 

www.sunearthinc.com 

SunEarfh, Inc. 

8425 Almeria Avenue, Fontana, CA 92335 
(909) 434-3100, FAX (909) 434-3101 
Distributor inquiries welcome. 



114 



home power 125 /june & july 2008 






"NATURE'S HEAD" 





COMPOSTING TOILET 



* Na Odor 

* Compact 

■ Exceptional 
holding capacity. 

■ Urine Diverting 

- An ^tjInlesA -SleeJ 
Hardware 

Great Far; 

*Wo itkt *CaMns 

*Raali 

-inrr ‘Jte_ 



www.sustainablechoice.net 

248.844.7148 






Western North Carolina 
Renewable Energy Initiative 

2008 Workshop Schedule 

4/5-6 Solar Water & Space Heating: 

with Chuck Marken of Home Power & AAA Solar 

4/19-20 Small Scale Wind Energy: 

with Southwest Windpower 

5/22-23 Photovoltaics: 

with Sharp Solar 

7/11-12 Domestic Solar Water Heating: 

with AET & Brandon Leavitt 




8/27 PV & The National Electrical Code: 

with John Wiles of the Southwest Technology Development Institute 

10/4-5 Micro Hydro: 

with Don Harris 

10/18-19 Small Scale Wind Energy: 

with Southwest Windpower 

Other North Carolina Events: 

March 8: Organic Growers School, Flat Rock, NC 
August 12-13: Western NC Green Building Council workshops, Asheville, NC 
August 22-24: Southern Energy & Environment Expo, Fletcher, NC 
November: NC Energy Star Conference, Raleigh, NC 

www.wind.appstate.edu 

828-262-7333 • email: wind@appstate.edu 
Bachelors and Masters degree programs available 



K Appalachian 

■V 1 1 STAl]-: rMVERSJTV 



State Energy Office 




7) PQpm" gk&B&uajg/p 




Four SunPipe-13's in 25 x 35 living room. 

The Best Daylight Pipe 
The Brightest Daylight Pipe 
No Heat Gain, Roof Leaks or Electricity 




WWW.SUNPIPE.COM - 800-844-4786 




WAirSUN 





YYatKiin S-olar Tfjcfcen 
Residential 


S-ng'c n DiMhAill Aivmuth 




f-rHiaa TlMEkif * rmKinl Mrf 


— - — 


J i- lip WjiTi cf p^iatovciNalc 




m ad ill#* 

Tt, jT 


1 


jC / / 

ggriinnwcMl 


1 




- ■ J 


Fixs-tfr-T-TI Aiimwih Stiiw 


■ | 


Tiacluri Uaunf i 1 tu A Liki ft jics 
HZ-Lnt*r AkIs Utaher* 


f j I 


lOlfriO fcliM Jrnj 


J 


he Lht biK iMJllEflng blocki 
UA PtfFWii Pljnln 


"mm * 


■AHRA.Y TFCHP-^QL QCIFS IRC 




F ! B 1 FTni B HI "I - ■ 1 T Iff S T ^BTH! ^ ^ 1 l 1 T B W i 

phene WS-8B1-T567 
i«: ■g7e ^M-57M 

WWW WATTSUH.COM 




Anl n.n Tl. Jin m il» 1. ml m ?>■ rU 



www.homepower.corn 






power politics 



Getting FIT 

by Michael Welch 




The recent changeover to a "greener" 
Congress is showing some benefits to 
the renewable energy world. 

Congress is now drafting bills to form federal policies 
supporting household and small-scale commercial RE that 
go way beyond net metering. Feed-in tariffs (FITs) may be 
the next promising step for RE development in the United 
States. 

Whereas net metering is designed to offset household or 
business usage, renewable energy FITs typically provide a 
premium price per KWH (as in production-based incentives, 
or PBIs) when a system produces more electrical energy 
than the building consumes. Some programs also pay 
that premium for offsetting usage even before the using/ 
producing breakeven. 

Incentives for both of these government-mandated 
programs — net metering and FITs — are funded through 
surcharges that all utility customers pay. The amounts used 
to fund these programs are charged on a per-KWH basis 
and lumped in with the utility's "public purpose programs." 
These have also been established to help cover the costs of 
providing assistance to low-income utility customers and 
financing energy-efficiency programs. 

Growing the RE Garden 

State-by-state net billing laws have served the renewable 
energy industry quite effectively so far, as indicated by the 
increasing number of home-scale PV and wind installations — 
and professional installers — in the states with effective rules, 
compared to those states without net billing. From an industry 
perspective, the point of those laws was to give a budding 
industry a little "fertilizer" to help it grow and gain solid 
roots to become self-sustaining. 

Now that the RE industry has established itself in the 
United States, it is time to propagate it by including those 
states that have not had the political will to establish their own 
effective programs. More nurturing incentives could shift the 
industry from its current status of "present and ready" to the 
next stage: rapid growth of manufacturing facilities, dealers, 
and installers and, with that, price decreases. 

The timeliness of this next step will be important to 
uprooting the weed of climate change. We must speed up 
necessary greenhouse gas reductions, or else risk reaching a 
tipping point beyond which global warming does not have 
a reasonable recovery scenario. Accelerating the growth of 
RE by taking incentives to the next phase can help achieve 
this goal. 



Feed-in tariffs are nothing new — Europe's successful 
systems of "rate-based incentives" have long been the envy 
of RE advocates in the United States — so understanding how 
they accomplish industry growth here should be predictable. 
The German model, perhaps most often heard of, has been 
triumphant at increasing the installation of RE in that country. 
Only one European country has more installed PV per capita 
than Germany's approximately 30 watts peak, and that is 
Luxembourg, with more than 50 Wp per capita from its wildly 
successful, but temporary, rate-based incentives program. 

The German model was so successful that its programs 
(along with a couple in other countries) temporarily created a 
worldwide shortage of PV modules. German installers were 
willing to pay higher-than-normal retail prices for modules — 
even within the wholesale market. Shipping containers 
full of modules were being resold into Europe from other 
countries — even coming directly from U.S. retailers and 
distributors — because the price was right. 

The key to the success of these programs was in making 
the tariffs as attractive as possible. The higher the profit 
potential for would-be system owners, the more likely they 
are to invest in systems. Considering the immediacy and 
risks of continued climate change, the price of PV energy 
generated on site could easily be valued at 50 cents per KWH 
or more — admittedly a seat-of-pants estimate, but in line with 
the German model and enough to make even the most thrifty 
of utility customers sit up and take notice. 

United States FITs Next? 

Leaders of both houses of Congress have drafted FIT bills. 
As of this writing, no bills have been introduced, but citizen 
input is being sought. In the House, Representative Jay Inslee 
is drafting The Clean Energy Buy-Back Act, which would 
amend the Public Utility Regulatory Policies Act (PURPA) 



116 



home power 125 /June & july 2008 





Presidential Promise 

While the threat of vetoing legislation not supported by 
the current administration still exists, bills introduced 
now may not even make it all the way through the 
current legislative session, which ends in the fall for 
both houses. This is good news, since this could 
delay the bills until after a new president is sworn in. 
The three viable presidential candidates are all more 
likely to support RE and climate-change legislation 
compared to the current administration. It is time 
to raise our hopes for a renewable energy, climate- 
neutral future, and to back them up by encouraging 
our Congressional representatives to work harder than 
ever to make it happen. 



to require utilities to enter into 20-year fixed-rate power 
purchase agreements and to set those rates to provide system 
owners with a reasonable rate of return on investment. 
Though the PBI amounts that have been so effective in Europe 
have not been specified in these bills, it would be a huge step 
forward as envisioned. 

Senator Bernard Sanders of Vermont is working on a bill 
that's similar to the Inslee draft in intent and content. His 
National Renewable Energy Sources Act would make PBIs 



power politics 



the law in all states. Both bills would amend PURPA, set rates, 
and spread out the costs among ratepayers, though no details 
exist yet. Neither draft precludes other state, federal, or local 
incentive programs, such as rebates and tax credits. 

Right now we have a unique opportunity to chime in 
before these drafts are finalized. Make sure that the legislators' 
staff understands the need for high PBIs if they truly want to 
see results as effective as the European programs. See Access 
for the contact information for Congressional staffers who 
are working on these bills. Then take the time to call your 
own representatives in Congress and ask them to sponsor 
the bills when the time comes. While you're at it, be sure to 
put in a plug for renewing the federal tax credits, which will 
otherwise expire on December 31, 2008. 



Access 

Michael Welch (michael.welch@homepower.com) has been working 
for a clean, safe, and just energy future since 1978 as a volunteer for 
Redwood Alliance and with Home Power magazine since 1990. He 
will be spending the next year in Sacramento, California, where he 
hopes to help hold the Governator to his RE promises. 

Representative Jay Inslee's Staff Contact: 

James Bradbury • 202-226-7449 • james.bradbury@mail.house.gov 



Senator Bernard Sanders's Staff Contacts: 

Jessica Maher • 202-228-6356 or Bill Hutzel • 202-228-6493 




$ 85.00 

KALER3 

WELCOME 



solar powered 

DIFFERENTIAL TEMPERATURE 
CONTROLLER 

Improves the performance 
of solar heating systems 
For 12 or 24 Volt DC pumps 

www.Art.TEcSolar.com 




DESIGN & INSTALLATION 

Red Lodge, MT • 406-855-8824 
www.effidentradiant.com • efficientrad iant@yahoo.com 



BZ Products Model MPPT250 

250 watt 25 amp Maximum Power Point Solar Control 

• Boost charge current up to 30% 

• Up to 25 amp output current 

• Microprocessor control 

• 95 % efficacy 

• 250 watt PV input 

• 12 to 24 volt input 

• Digital metering 

• PWM float control 

• Battery temperature sensor 
standard 

• 15 amp low voltage 
disconnect standard 

• Aux battery trickle charger standard 

• Five year warranty 

• Made in U.S.A. 

BZ Products, Inc. 

644-2490 • www.bzproducts.net • bzp@bzproducts.net 
7914 Gravois, St. Louis, MO 63123, USA 






Artha 

— #■ * ■* — 

[ iviiift ( / rtlc-r 

Solar Thermal Services 

professional site assessments 

system design and consulting: 

1 i commercial & residential, domestic & space heating 

^ hands-on installation training workshops: 

_® on or off site, NABCEP continuing education 

CD 

| www.arthaonline.com 



www.homepower.corn 



117 







PV PE 




IALS 



Simple. 



acme conduit entry (ACE) 

hassle free wire transition, 
any conduit type 



Safe. 










washer, electrical equipment bond (WEEB) 

bonds modules to racking for safer grounding, listed to UL 467 

Available for: Professional Solar, UniRac, DP&W Power Rail, Two Seas, Schuco, Conergy 

Secure 

acme cable clip (ACC) 

easy installation, non corrosive stainless steel 

Available for USE-2 and PV Wire 



Accurate 




acme solar site evaluation tool (ASSET) 

digital solar site evaluation with user friendly software 



/WILEY 

r j ELICTMHtCL LLL 



Tel: (845) 247-2875 
(845) 633-2065 
www.we-llc.com 




SliNDA Evacuated Tubes 



Aerpspaca TBchnpIpgv for 

Sular W ater Heating 



Alfonfable vacuum lube coHetl&O 
lor supertoi partarmanBe in fri 
E-taions a^vJ rirrMSSs 



frmntG lid Wate* 5 Home n w ng 

Cuyn-n-ii^i f hn imuKrt^l 
AfrtOiRuf Jj i" KhZullfb* 



u.u 



Ari Jilatil#- rjh-;LH#C |i IPuni^h jn 
axpasiiliiiy iIitbIm nnlw:iifei 
JO ' 1 1 uu r UM I 

T<ikilnn And LtchnJcfeliujppMi 



SjIi SfKA SlMjt 

PD Bs>x E-5- 

M WdlwC*p. PA f BUT 

Inl^mL-icUrd^nt I Iijfi*iYi 



Want to Save More Energy & Water? 

.Vim? (iM//r»i.v fwi/i /.avh/ H jJ/j .Vfflfter/ 



5TABER 

Only Top Horisonta}- AsH Wi^lior 
Miidf In Ihe USA-Great forOIT-Griil System i! 

-Av*g. irf I * gillcn (if tvOIct A. I 
i.i i iQrif pvi 3 iki( 1 
'AW ill jLnl .15 LA\1| fliM Ii jJ 
rilJiifclL-- > -Lied mriLi if guIlt IlMil 
-Dim] Kviuiui '.n liunl <£ real cVi 
Jlurdb-ilin 

OCp li .in: rubber vJ--LlI Id yl-ihti 
jhiul k.ikj iHf ur n iI-.Il'.i 
- lulal friTTil iu- part*— htvtJ 

r mipk J^Titqn oq ski* m irttf 
-Sills : 1 1 -J-L Kill i _ . L I rwrtLhCt—fh> 

L\p-wEHfc'ii_ lIlJIi-N-l h|;-|,-.n^! 

■|[t^li c\li j.n.1i-;ui *pm ■■I'-ciJ 

-MADE i>:tiie usai 

| C hIT I -86 0-848-6200 to Iffini more! [ 
sm^tibcrnni 

Sbln liiJiiHim. In: «» Him Ofa. tdi OH 411V H| 






Energy Efficient 
Refrigerators & Freezers 



Customized To Fit Your Needs 



► Available in DC 
or AC 

► Select From Over 10 
Models 

► Choose from 1000's 
of Colors, Finishes fit 
Woods 

We also Manufacture 
Composting Toilets! 

Please Contact (Is For More Info 

P.O. Box 1101. Areata. Cfi 95518 
tel: (707)822-9095 - fax: (707)822-6213 info@ 
sunfrost.com ■ www.sunfrost.com 




118 



home power 125 /june & july 2008 








3622 South Morgan Street 
Chicago, Illinois 60608 
T 773.847.8333 F 773.847.8555 



www.solargenixchicago.com 

info@solargenixchicago.com 

The Winston Series 

Parabolic Concentrating Collector 

Designed at the University of Chicago; 
Manufactured in the USA 



Solargenix - An Enlightened Approach 
to Solar Thermal Energy 





Introducing the S-5-PV Kit, a 
revolutionary new solution to attach solar PV 
panels to standing seam metal roofs! 



Crystalline PV modules mounted 
with the S-5-PV Kit to a standing 
seam metal roof produces a 
reliable 30-year alternative power 
source. The patented design of the 
attachment clamp and attendant 
round-point setscrews enables an 
entire installation without a single 
penetration of the roofs surface! 
Installation is quick and easy. 

888-825-3432 www.S-5.com 





Low head turbine: 

• Works with heads 
of 2 to 10 feet 
and large flows 

• Low flow 
runner option 

Higher head turbine: 

• Operates at heads 
of 10 feet and up 

• High output wheel 
option for heads 
over 50 feet 

Both turbines: 

• Use permanent 
magnet brushless 
alernators 

• Charge 12, 24, 48 
Volt batteries or 
higher voltage for 
long distance 

• Have cast 
bronze runners 

• Generate up to 1 KW 
or more at best sites 




Energy Systems & Design 

“ Innovative turbines since 1980” 
Manufacturing cost-effective 
water powered generators 
For more information: 

www.microhydropower.com 

506-433-3151 



NABCEP 

CERTIFICATION 



Get THE Distinquished Mark 
for Renewable Energy Professionals 

Since 2003, the North American Board of Certified Energy 
Practitioners (NABCEP) has been awarding professional credentials 
to renewable energy installers. NABCEP’s rigorous competency 
standards for certification sends a clear message to consumers, 
financers, and public officials that the Industry stresses high quality, 
safe and ethical business practice and workmanship standards. 

NABCEP PV or Solar Thermal Certification... 

THE One That's Hard to Get 

To find out how to become a Certified Installer please visit: 

www.nabcep.org 

Next NABCEP Exam September 13th 




www.homepower.corn 



119 









\m® 

Pod 






Home Field 



by Kathleen Jarschke-Schultze 



Fve often been amused by the " green speak" that's grown 
up around diet choices. There are the vegans (no animal or 
animal by-products of any sort are consumed), the vegetarians 
(no food from flesh), the aquarians (eat seafood), pesco-pollo 
folks (eat fish and poultry), the beady-eyed vegetarians (if it 
has beady eyes, they'll eat it), the omnivores (eat anything 
and everything), and the opportunavores (eat what's placed 
in front of them). Now there are some new words in the 
lexicon of diet choices. 

Living la Vida Locavore 

I've just finished listening to the audio book of Barbara 
Kingsolver's Animal, Vegetable, Miracle: A Year of Food Life 
(www.animalvegetablemiracle.com) for the second time. It is 
so inspiring and informative on many levels. Barbara's family 
of four chronicles a year living as locavores. 

A locavore (sometimes called localvore) is someone who 
gets their food — animal or vegetable — from within 50, 100, or 
150 miles of their home, depending on their region. Their larder 
comes generally from their own gardens, a CSA (community- 
supported agriculture) farm, and local farmers markets. 



Locavores support their local economy by local purchasing. 
This is also called "food patriotism." 

Groovin’ on Sole Food 

An ethicurian is someone who seeks out tasty things that are 
also sustainable, organic, local, and ethical — SOLE food, for 
short. This is the definition at www.ethicurian.com, whose 
motto is, "Chew the right thing." 

After seeing the video clips of the cruelty to cows at a Chino, 
California, beef-processing plant, which resulted in the recall of 
143 million pounds of frozen beef. I'm a converted ethicurian. 
The undercover video, shot by the Humane Society of the 
United States, showed workers abusing "downer" animals that 
were apparently too sick or injured to walk into the killing box. 

Federal regulations call for keeping downed cattle out 
of the food supply because they may pose a higher risk of 
contamination from E. coli, salmonella, or mad cow disease, as 
a result of their weakened immune systems and being forced 
to wallow in their own feces. Of course, after the fact, we found 
out that a lot of the meat from this plant was sold to school 
lunch programs and had been eaten by children already. 



home power 125 /june & july 2008 





home & heart 



In the United States, about one-tenth of 1% of beef cattle 
are tested for mad cow disease. In Europe and Japan, 100% 
are tested. The human form of mad cow disease happens 
when infected cows are eaten by people. The cows get it from 
eating ground-up cow waste. After the mad cow scare, the 
United States banned feeding cow waste to cows. Now they 
feed it to chickens and pigs. And then they feed chicken waste 
to cows. This process does not eliminate mad cow disease. It 
simply travels through the literal loops — as viable as ever. 

Shop, Shop Around 

Growing your own meat is a big undertaking. If you can do 
it, great. If you can't, the next best thing is to know the person 
who raised it. Right now my Sun Frost freezer is holding half 
of a hog my husband Bob-O and I bought from people we 
know. Many local markets now offer a number of "ethical" 
choices for meat and fish. Farm-raised, grass-fed, pasture- 
finished, free-range — we all should become familiar with 
these terms if we're into SOFE food. 

Of course, few of us can grow all our own food — even 
those of us with big gardens can't grow every single thing we 
want. Weather and geography intervene. To eat seasonally 
where I live would take a lot of canning, freezing, and drying. 
I am lucky that there is a wealth of farmer's markets, local 
vegetable stands, and natural food stores around here. To find 
local food supplies in your area, visit www.localharvest.org. 

Sustainability Grows 

Michael Pollan, author of The Omnivore's Dilemma: A Natural 
History of Four Meals and In Defense of Food: An Eater's 
Manifesto (www.michaelpollan.com), has a few suggestions. 
He says don't eat anything your great-grandmother wouldn't 
recognize as food. Similarly, he advises, if a packaged product 
contains more than five ingredients, it's probably not food. He 
removed the lawn at his home in the Bay Area and put in a 
vegetable garden. 

I know people who are and have been ethicurians before 
there was a word for it. Vegetarians Sue Robishaw and 
Steve Schmeck (www.manytracks.com) experimented with 
really local food, living for a year on what they could raise 
themselves. This was years ago, and I remember Sue saying 
vegetable oils were a stumbling block for them. 

A couple of years ago, I took Earisa Walk's workshop, 
"Eating From Your Garden Year-Round," at the Midwest 
Renewable Energy Fair. She and her partner Bob Dahse have 
the most wonderful Web site (www.geopathfinder.com). For 
their tips on growing local, click on "Veggie Homesteading" 
and "Food Preservation." 

Keeping It Real 

This cascading revelation about locavorism has impressed me. 
I've been growing only open-pollinated seeds for years (www. 
bountifulgardens.org). These are seeds that can be saved from 
the mother plant and will grow true when planted. Heirloom 
varieties, as they are often called, are enjoying increasing 
popularity. I try my hand at saving some seeds, the easy ones. 
I had a friend who told me once to let one of everything go to 
seed in my garden. I always have a lot of volunteers — plants. 



Regional Eating 

In winter, when you shell out a few bucks to buy a 
tomato, cantaloupe, or grapes at your supermarket, the 
real costs of growing and shipping are not revealed. 
How much did it cost to get them there? The importer 
doesn't care. They get to deduct the cost of transport. 
But resources are being used. Oil is being used up. 

Even within the United States, enormous amounts of 
fuel are used to transport factory farm produce across 
our country. CUESA (Center for Urban Education about 
Sustainable Agriculture; www.cuesa.org) estimates that 
the average American meal travels 1,500 miles from field 
to fork. It is estimated that if every family in the country 
ate just one meal per week from locally procured food, 
we could save 1.1 million barrels of oil per week. 

Eating regionally and getting your food locally not only 
reduces reliance on fossil fuel, but it helps keep dollars 
local, stabilizing regional economies. An additional 
benefit is that it helps keep our communities healthier — 
fresh, organic, whole, locally harvested foods have more 
vitamins and minerals than their packaged counterparts 
and none of the pesticide residue possible in factory- 
farmed or imported foods. 

Choosing local rather than processed foods also keeps 
trans fats and high-fructose corn syrup, which have been 
linked to heart disease and diabetes, off our shelves and 
out of our diets. Adult-onset diabetes has been renamed 
Type II diabetes because so many children have become 
victims. Sadly, for the first time in history, the current 
generation of children is not expected to have a longer 
life span than their parents. 



that is. I've also learned that when the lettuce volunteers come 
up, it is time to plant lettuce. When the potato volunteers 
break ground, it is time to plant potatoes. 

My locavore challenge is to figure out what produce I 
end up buying at the grocery store and to see if I can grow 
that particular variety at my house. For my kimchee recipe, I 
can make or grow every ingredient except napa cabbage. But 
this year I bought a slow-bolting, open-pollinated variety. If 
I can get it to head up in the dry heat. I'll not only have my 
kimchee cabbage, but also will be able to save seeds and add 
them to my seed bank for next year. Of course, that means I 
need to organize my collecting better. While cleaning off my 
desk recently, I came across a taped-shut, half-used envelope 
of "Cabernet Fettuce '07." 

Green Food Housing 

I have been using a small lean-to greenhouse for starting 
seeds. I framed in the area beneath the 3-foot overhang on the 
southeast side of our house, and put up fiberglass greenhouse 
panels and a door at both ends. When we replaced our 
windows in the house with double-paned units, I mounted one 
of the old windows above one of the doors for ventilation. 

For a planting table, I built a long, two-shelved bench 
and covered it in hardware cloth. For years, this is where I 



www.homepower.corn 




home & heart 



have started my seedlings. My problem has been the mice 
that come and eat my seedlings or dig up the seed before 
it has even sprouted through the dirt. The greenhouse is 
so ramshackle that I could never completely seal it against 
rodents, and the whiskered critter invasion has been so 
discouraging that I had taken to buying organic starts 
rather than starting my own. 

So this year I bought an 8- by 7.5-foot greenhouse. Since it 
is constructed as one piece. I'm hoping it will end my mouse 
problems and enable me to enlarge my gardening repertoire. 
I'm trying several new varieties this year, thinking ahead to 
saving seed and preserving the crop. I've taken to buying 
a vegetable variety to see if we like it, and then see if I can 
grow it. 



ELECTRIC BIKES 

“No better quality at no better price” 



800 - 806-7109 





Complete BIODIESEL Production System 




Lower Your Fuel & Energy Cost TODAY! 

Dealer Opportunities Available! 

- Make Fuel the Day It Arrives 

- Safe, Durable, & Effective 

- Completely Assembled and Tested 

- Handles New or Used Vegetable Oil 

- Consultation Services Available 

- Monthly Biodiesel Seminars! 

The Ester Machine™ 



We Have theAnswers to Your Biodiesel Questions! 

Green World Biofuels www.greenworldbiofuels.com 319-545-7022 



Chock o’ Choices 

There are a lot of factors involved in being a locavore or 
becoming an ethicurian. It doesn't have to be done all at once. 
Awareness is the first step. It's a lot of commitment, effort, 
and self-education to make choices that support the ideals you 
believe in. I have to admit that it's going to be hard giving up 
bananas. Maybe I can relieve my conscience by just buying 
the aged ones that are already wearing red discount ribbons. 
And thank goodness for fair-trade goods, 'cause we're not 
ready to give up coffee — or chocolate, for that matter. 

Access 

Kathleen Jarschke-Schultze (kathleen.jarschke-schultze@homepower. 
com) is enjoying her new greenhouse at her off-grid home. 




LIVING WITH NATURE 
IV 

“ Sustainable Living & Green 
Building Festival ” 

Marathon, Texas 

August 1-3, 2008 

www. livingwi thnatur e . net 



i 

If 



Things that Work! 
Model 4-1850 
Honi.e Power -#6 ~ 



Digital Power Meters 

20-CTR: Measures AC Power up to 10 
kW, 100-250 vac single or two phase. 

New USB plug in meter, up to 1 gig of flash memory! 



ONEMeter: Standard Features include Multiple AC or DC power 
channels, PC interface, internal logging. Options include Web 
Interface, Weather Monitoring, and lots more. 



4-1850WX: Special meter for Refrigerator Replacement 
Programs. Detects Defrost Cycle, displays cost/kWh-hrs/yr. 

Other Models available. Check our website or call for details. 



All products are California 
CEC eligible meters 



Brand Electronics 

info@brandelectronics.com 



Ordering or Information call 

12891 - 315-7744 

www. brandelectronics. com 



Why not use free energy? 




ENERGV WISE 



SOLUTIONS 



ENERGV WISE 
SOLUTIONS 

Your one-stop 
renewable energy 
online store 

980-621-0716 



www.energywisesolutions.net 



home power 125 /june & july 2008 









COMBINE SCIENCE & HANDS-ON TRAINING 
FOCUS ON PHOTOVOLTAIC DESIGN AND INSTALLATION 
TWO YEAR A.A.S. DEGREE OR 
ONE YEAR CERTIFICATE PROGRAMS 
BOTH EMPHASIZE FULL N.E.C. COMPLIANCE 
PLEASE VISIT US ONLINE AT WWW.SanjuailCOlle9e.edu/ren9 

■V VH FOR ADDITIONAL INFORMATION ABOUT THE 
RENEWABLE ENERGY PROGRAM AT 
SAN JUAN COLLEGE, FARMINGTON, NM 
PLEASE CONTACT: TOM MUNSON 
(505) 566-3003 OR (800) 241-6327 
munsont@sanjuancolle9e.edu 



NABCEP 

CERTIFICATION 



Select a NABCEP certified PV and solar thermal 
installer for the highest quality installation 



“our PV system was a 
big investment in the 
future and I wanted it 
installed by a profes- 
sional with national 
credentials to make 
sure it was installed 
properly. The NABCEP Certified installer 
did just that, and the system is operat- 
ing flawlessly.” 

Mike Burnetter, Home Owner 

and Professional Engineer 



The North American Board of Certified Energy 
Practitioners (NABCEP) awards professional 
certification to solar electric (photovoltaics) 
and solar thermal installers. NABCEP’s high 
standards are designed to protect consumers 
and enhance the profession. 

Select an installer with the NABCEP PV or 
Solar Thermal Certification. . . 

THE One That's Hard to Get 




To find nationally recognized Certified Solar Electric and 
Solar Thermal installers in your area go to: 



www.nabcep.org 




SOLJPffST 2006 

The New England Renewable Energy Festival 



Three days of workshops, music and 
performances promoting, celebrating and 
enabling sustainable living 
and renewable energy. 

• 50 free workshops 
• Over 1 00 vendors and exhibitors 



Children^ activities 
camping 

r week long 



oui 



• On-site c 
Sign up now for 
in-depth PV101 workshop 

July 11, 12 & 13 



Forget-Me-Not Farm Ti 
Tickets on sale 

Sponsored in part by: 
Forget-Me-Not Farm, Darkst 
Noble Environmental 

■aaEierg 




1011th, VT 



& Production 
tBack Power Systems 
>lar 



Info & Tickets at www.solarfest.org 





Cells* & Battery Boxes 
Universal Track Racks™ 

& More 



Ptfrtri • 



Zome works Corporation 



&00-279-S342 " jpmrwtirkWjrOrwcwgrisManil 

Simple, Reliable Products 

See Double Play Systems Performance 
w ww.zo mewo rks.co m 



www.homepower.corn 










Do You Need Batteries?... 



RAE Storage Battery Company 

Since 1943... Quality & Service 

Surrette Solar 1, 400 Series, 

Type CH 375 - LI 6 

Engineered under careful guidelines 
by Dave Surrette - Family owned 
business Est. 1 935 

Gambissara Solar for export 

212-206-6344 • 1201 Broadway, 

Room 809, New York, NY 10001 

Newly established factory 
warehouse. U.S. Battery Co. 

Corona, CA 

Phone 860-828-6007 
Fax 860-828-4540 

51 Deming Rd., POB 8005, 
Berlin, CT 06037 





BZ Products Model MPPT500 

500 watt 45 amp Maximum Power Point Solar Control 

• Boost charge current up to 30% 

• Up to 45 amp output current 

• Microprocessor control 

• 95 % efficacy 

• 500 watt PV input 

• Universal PV input 12 to 48 volts 

• 12, 24 or 48 volt output 

• Digital metering 

• PWM float control 

• Battery temperature sensor standard 

• Five year warranty 

• Made in U.S.A. 



BZ Products, Inc. 

i-2490 • www.bzproducts.net • bzp@bzproducts.net 
7914 Gravois, St. Louis, MO 63123, USA 





• Simmons • 




Natural Bodycare 

si mmonsnatu rals.com 
MAKING 
EVERYDAY 
SPECIAL 

Off the grid since 1982 . 

A SUSTAINABLE FUTURE 




PC Software for Sine Inverters 
Wit iVerter m 



rQHIl jpiliRTll 



xantrex 



www.RiBhTHandErq.CQm |425) 844-1291 



WINDMAX 

( 't ) Wind Energy Store (f? 



Top quality, efficient, do-it-yourself wind turbine components 




^Powerful Neo Magnets 
^High Efficiency Blades 
^Top Quality Magnet Wire 
^Wind Generators 
^Wind turbine plans 



Wind Max Energy - Future of Ren 

Phone: 1-877-801-9778, 972-801-9778 
Web: www.magnet4less.com 
Addr: 1111 Summit Ave. #8, Plano TX 75074 



ewable Energy 

1 *r\i 







w 




"Tfcv 











'78 

TX 7507 A 



■ r ft 







WITH 


JT-j 


WWM 6W??X 


Ck - . 

* ^Sr 5 * 1 


ULTRA LOW ENERGY 


with only 25 - 130 WATTS! 


t ' • « 


The most efficient coolers on the planet. 
12, 24, & 48 Volt DC Evaporative Coolers. 


ft ^ 


Also available in 120 & 240 Volt AC. 




Made from Stainless Steel = Long Life! 




KAR KOOL FOR YOUR VEHICLE 




Call SOUTHWEST SOLAR 


We Make COOLING Your Lowest Electrical Load! 


(520) 885-7925 Tucson, Arizona, USA 


southwest-solar, com 



BATTERY BOX 

VENTILATOR 

& BACK DRAFT DAMPER 

www.zephyrvent.com 

Available from dealers and distributors 
in the U.S., Canada and Australia. 

ZEPHYR INDUSTRIES -POB 52. SALIDA, CO 81 201 • 719.530.0718 





Harness the energy from the most powerful 
muscle group in your body. 

Generate efectricity with your bicycle 
L and the Bike Power Generator. 

% 

www.windstreampower.com 



sales@windstreampower.com 
Phone 802-425-3435 
FAX 802-425-2896 



home power 125 /june & july 2008 








LED LIGHT BULBS 



Save Over 90% On Your Lighting Bill 
60,000 Hour Bulb Life (est.) • 2-year Warranty • © 



UL Listed 




CC Vivid PAR 38 
LED Spotlight 

• Outdoor Sensor 
or Exterior Lighting 

• 72 Bright White LEDs 

• 8 Watts / 12 or 120 Volt 



CC Vivid + 
LED Light Bulb 

• Porch, Reading or 
Ambient Light 

• 36 Bright White LEDs 

• 3 Watts/ 12 or 120 Volt 



CC Vivid PAR 20 
LED Flood & Spot 

• Ceiling or Garden 
Accent Lighting 

• 36 Bright White LEDs 

• 3 Watts / 120 Volt 



CC Vivid PAR 30 
LED Floodlight 

Ceiling or Garden 
Accent Lighting 
•60 Bright White LEDs 
• 6 Watts / 120 Volt 



These bulbs fit most standard fixtures. 
Additional sizes and voltages available. 



d.d RFINIEL 

800-522-8863 • ccrane.com 



w 

E@ 



WIND DATA LOGGER 

for wind site assessment, 
turbine monitoring, 
and weather station 
applications 

High performance and very low 
cost. Supports multiple anemo- 
meters, wind vanes, temperature, 
relative humidity, light level, 
voltage and current, and many 
other sensors. 

Logs directly to removable Secure Digital card. PC and cell phone 
interfaces available to capture live data and send to the internet or 
through e-mail. Ready to go packages available — just give us a 
call or visit our website! 



APRS World, LLC 

Phone: +1 -507-454-2727 Web: www.winddatalogger.com 
902 East Second Street, Suite 320, Winona, MN 55987 





Off-Grid Solar Energy 
Specialists 

We’ll help you through the confusion 
with the best design and components 
for your off-grid installation. 



8+ years solar installation experience 
• Full support for do-it-yourselfers 
► Wiring diagrams for your system 
» Packaged systems available 




CSffJf 

off Major 
Brands 



We can build it -you can install it. 

toll-free: 888-782-0706 

7 www.apxsolar.com 



HYDBDSCRtIH CD. llfi 



• Self Cleaning 

• Easy Installation 

• High Capacity 

• No moving parts 

• Pipe , ramp and 
box mountings 



Precision Wedge Wire 
Coanda Screens 

for Hydro, Agricultural, and 
Domestic Diversions from 
10 gpm to 500 cfs 



- We specialize in creatively engineering solutions 
for your unique hydro diversion screening needs. 

- Our solutions are cost effective with numerous 
screen mounting options; we also have 
durable 304 SS mounting boxes. 

Visit us at www.hydroscreen.com 
or call (303) 333-6071 
e-mail: RKWEIR@AOL.COM 
We don’t just sell screens, 
we engineer solutions! 




JWP-Jan Watercraft Products 

Battery Watering Made Easy! 





RV, Off Grid 
Marine 



Golf Carts 



PRO-FILL is not only for your “HOME POWER” 
applications. You can also use on your RV, camper, boat, golf 
cart... Get the picture? Visit our web site to see ALL of these 
applications. PRO-FILL, the most convenient and accurate 
means of filling and maintaining battery water levels. Period! 

5 year warranty, free shipping in USA. 



VISA 



Distributed by: JWP 
E-mail: sales@janwp.com 
Call Bob- 1-616 822-7587 




www.janwp.com 




NO Gas 
NO OH 
NO Carbon 

NO Warming 

NO Smog 



NO Wars , 



info@ Gorilla Vehicles, com 

PLEASE SEE OUR WEBSITE 

or call for a brochure package 



Gorilla Vehicles 
5842 McFadden Ave, Unit R 
Huntington Beach, CA 92649 
(714) 377-7776 




www.homepower.corn 






SOLAR WATER HEATING 

Commercial • Residential 



Solar Radiant Floor 



26 years 

of industry leadership 




Temperature Limited 



New Mazdon HP 200 System 



solarthermal.com 



IT'S ALL IN THE 
VACUUM 



Save up to 80% on 
Heating bills 
All weather performance 
Low Maintenance 



zev@solarthermal.com 



Call Toll Free 



1 - 888 - 923-9443 



Ask About Dealerships 



RE happenings 



U.S.A. 

CALIFORNIA 

Jun. 9-11, '08. San Francisco. PV System 
Design — Producing PV design documents. For 
engineers & designers. Info: 707-869-9391 • 
www.sunengineer.com/workshops.htm 

Jun. 18-20, '08. San Diego, CA. PV Summit 
2008. Industry & market trends. Updates on 
silicon supply, PV technologies, concentrated 
PV, next generation thin-films, dye-sensitized 
solar cells, organic PV & emerging applications. 
Info: www.intertechpira.com 

July 15-17, '08. San Francisco. Intersolar 
North America. Exhibition focuses on 
photovoltaics, solar thermal technology, and 
solar architecture. Seminars & workshops on 
current industry trends. Info: Solar Promotion 
International GmbH • 415-248-1257 • wagner@ 
intersolar. us • www.intersolar.us • 

Jul. 22-24, '08. San Jose, CA. Plug-In 2008 Conf. 
& Expo. Latest tech advances, market research 
& policy initiatives on plug-in hybrid-electric 
vehicles (PHEVs). Info: www.plugin2008.com 

Aug. 10-14, '08. San Diego, CA. Solar Energy 
Applications, a part of SPIE Optics+Photonics 
conf. Tech presentations & courses on PV; R&D 
of solar concentrators & solar hydrogen. Info: 
www.spie.org 

Aug. 16-17, '08. Hopland, CA. SolFest. RE 
booths, workshops & kids' activities. Food & 
entertainment. Info: www.solfest.org 

Oct. 13-16, '08. San Diego, CA. Solar Power 
2008. Conference & expo. Info: SEIA • 
202-296-1688 • mglunt@solarelectricpower.org • 
www.solarpowerconference.com 

Areata, CA. Workshops & presentations on RE 
& sustainable living. Info: Campus Center for 
Appropriate Technology • 707-826-3551 • 
ccat@humboldt.edu • www.humboldt.edu/~ccat 

Hopland, CA. Workshops on PV, wind, hydro, 
alternative fuels, green building & more. Solar 
Living Institute • 707-744-2017 • sli@solarliving. 
org • www.solarliving.org 

COLORADO 

Sept. 20-21, '08. Fort Collins, CO. Rocky Mt. 
Sustainable Living Fair. Exhibits, workshops, 

RE, alternative vehicles & more. Info: Rocky Mt. 
Sustainable Living Assoc. • 970-224-3247 • 
kellie@sustainablelivingfair.org • 
www.sustainablelivingfair.org 

Crawford, CO. Solar Energy for Do-It- 
Yourselfers '08 workshops: Jun. 6-7: Solar 
Ovens, Cookers & Dryers; Jun. 14-15: Intro to 
PV; Jun. 27-29: Batch Solar Water Heaters; Jul. 
12-13: Solar Hot Air Collectors. Info: Our Sun 
Solar - 970-921-5529 • 
www.solarenergyclasses.com 

Carbondale, CO. Workshops & online courses 
on PV, water pumping, wind, RE businesses, 
microhydro, solar hot water, space heating, 
alternative fuels, straw bale building, green 
building, women's PV courses & more. Info: 
Solar Energy Inti. • 970-963-8855 • sei@ 
solarenergy.org • www.solarenergy.org 



FLORIDA 

Melbourne, FL. Green Campus Group meets 
monthly to discuss sustainable living, recycling 
& RE. Info: fleslie@fit.edu • http://my.fit. 
edu/~fleslie/GreenCampus/greencampus.htm 

ILLINOIS 

Aug. 9-10, '08. Oregon, IL. IL RE & Sustainable 
Lifestyle Fair. RE booths, workshops, tours & 
kids' activities. Food & entertainment. Info: 
www.illinoisrenew.org 

IOWA 

Sep. 13-14, '08. Cedar Falls, IA. I-Renew 
Energy Expo. Workshops, exhibits, food, 
entertainment. Info: See listing below. 

Iowa City, IA. Iowa RE Assoc, meetings. Info: 
319-341-4372 • irenew@irenew.org • www.irenew.org 

MASSACHUSETTS 

Sep. 15-17, '08. Boston. Alternative Energy 
Sources & Technologies. Conf. & exhibition on 
biomass, biofuel, geothermal, hydro, hydrogen, 
solar, wind & waste-to-energy. Info: 
www.cardellexpo.com 

Auburn, MA. Seminars: Solar Basics, PV, Hot 
Water, Wind, RE & more. Info: CNE Solar Store • 
508-832-4344 • peter@cnesolarstore.com • 
www.cnesolarstore.com 

Hudson, MA. Workshops: Intro to PV; Advanced 
PV; RE Basics; Solar Hot Water & more. Info: 
The Alternative Energy Store • 877-878-4060 • 
support@altenergystore.com • 
http://workshops.altenergystore.com 

MICHIGAN 

Jun. 27-29, '08. Onekama. Ml Energy Fair. 

RE, EE, green building & alternative vehicle 
workshops & vendors. Food & music. Info: 
www.glrea.org 

Jul. 3-6, '08. Rothbury, Ml. Music festival. RE, 
climate action, sustainable living. Info: 
www. roth b u ryf estiva I .co m 

West Branch, Ml. Intro to Solar, Wind & Hydro. 
1st Fri. each month. System design & layout for 
homes or cabins. Info: 989-685-3527 • 
gotter@m33access.com • 
www.loghavenbbb.com 

MISSOURI 

New Bloomfield, MO. Workshops, monthly 
energy fairs & other events. Info: Missouri 
Renewable Energy • 800-228-5284 • info@ 
moreenergy.org • www.moreenergy.org 

MONTANA 

Whitehall, MT. Seminars, workshops & tours. 
Straw bale, cordwood, PV & more. Info: Sage 
Mountain Center • 406-494-9875 • 
www.sagemountain.org 

NEW HAMPSHIRE 

Rumney, NH. Green building workshops. Info: 

D Acres • 603-786-2366 • info@dacres.org • 
www.dacres.org 

NEW MEXICO 

Jun. 27-29, '08. Taos, NM. Taos Solar Music 
Festival. Solar-powered music, food & displays. 
Info: www.solarmusicfest.com 



home power 125 /june & july 2008 







Sep. 20-21, '08. Albuquerque. Solar Fiesta. RE 
& EE exhibits & workshops. Info: 
www.nmsea.org 

Six NMSEA regional chapters meet monthly, 
with speakers. Info: NM Solar Energy Assoc. • 
505-246-0400 • info@nmsea.org • 
www.nmsea.org 

NEW YORK 

Jun. 21-22, '08. New York City. Renewable 
Energy Finance Forum. Info: 
www.euromoneyenergy.com 

NORTH CAROLINA 

Aug. 22-24, '08. Fletcher, NC. Southern Energy 
& Environment Expo. RE displays, exhibits & 
presentations. Info: www.seeexpo.com 

Beech Mt., NC. Western NC RE Initiative 2008 
workshops: Jun. 20-21: Community-Scale 
Biodiesel Production; Jul. 11-12: Domestic 
Solar Water Heating; Aug. 27: PV & the 
National Electric Code; Oct. 4-5: Microhydro. 
Info: WNCREI • 828-262-7333 • wind@ 
appstate.edu • www.wind.appstate.edu 

Saxapahaw, NC. Solar-Powered Home 
workshop. Info: Solar Village Inst. • 

336-376-9530 • info@solarvillage.com • 
www.solarvillage.com 

OHIO 

Sep. 1, '08. Johnstown, OH. Ohio Green Living 
Fayre. RE, sustainable building, alternative 
fuels, food, music, kids stuff & more. Info: 
jay@bluerockstation.com • 
www.ohiogreenliving.org 

OREGON 

Jul. 25-27, '08. John Day, OR. SolWest RE Fair. 
Exhibits, workshops, speakers, family day, 
music, alternative transportation & Electrathon 
rally. Info: EORenew • 541-575-3633 • info@ 
solwest.org • www.solwest.org 

Cottage Grove, OR. Adv. Studies in Appropriate 
Tech., 10-week internships. Info: Aprovecho 
Research Center • 541-942-8198 • apro@efn.org • 
www. apro vecho.net 



PENNSYLVANIA 

Sep. 20-21, '08. Kempton, PA. PA RE & 
Sustainable Living Festival. RE, natural building 
& sustainable ag; workshops, speakers, 
exhibits, vendors, music & kids' activities. Info: 
www.paenergyfest.com 

Philadelphia Solar Energy Assoc, meetings. 

Info: 610-667-0412 • rose-bryant@verizon.net • 
www.phillysolar.org 

RHODE ISLAND 

Jun. 7, '08. Coventry, Rl. Sustainable Living 
Festival & Clean Energy Expo. RE workshops, 
vendors & music. Info: www.livingfest.org 

TENNESSEE 

Summertown, TN. Workshops on PV, 
alternative fuels, green building & more. Info: 
The Farm • 931-964-4474 • 
ecovillage@thefarm.org • www.thefarm.org 

TEXAS 

Aug. 1-3, '08. Marathon, TX. Living With 
Nature, Sustainable Living & Green Building 
Festival. Lectures, workshops, tours & vendor 
displays on eco-construction, off-grid living & 
more. Info: LWN • 432-386-4257 • sowelo2000@ 
yahoo.com • www.livingwithnature.net 

Sep. 26-28, '08. Fredericksburg, TX. RE 
Roundup & Green Living Fair. Exhibits, 
speakers & workshops on RE, green building, 
green ag & EE. Info: www.theroundup.org 

El Paso Solar Energy Assoc. Meets 1st Thurs. 
each month. Info: EPSEA • 915-772-7657 • 
epsea@txses.org • www.epsea.org 

Houston RE Group, quarterly meetings. HREG • 
hreg@txses.org • www.txses.org/hreg 

VERMONT 

Jul. 11-13, '08. Tinmouth, VT. SolarFest. Solar 
powered music & RE festival. Info: 
www.solarfest.org 

WASHINGTON STATE 

Jul. 18-19, '08. Shoreline, WA. Shoreline 
Sustainable Living & RE Fair. Exhibitors & 
speakers. Info: www.shorelinesolar.org 



RE happenings 

WISCONSIN 

Jun. 20-22, '08. Custer, Wl. RE & Sustainable 
Living Fair (aka MREF). Exhibits & workshops 
on solar, wind, green building, alternative 
transportation, energy efficiency & more. 

Home tours, silent auction. Kids' Korral, 
entertainment, speakers. Info: See MREA listing 
below. 

Custer, Wl. MREA '08 workshops: Basic, Int. & 

Adv. RE; PV Site Auditor Certification Test; Veg. 

Oil & Biodiesel; Solar Water & Space Heating; 

Masonry Heaters; Wind Site Assessor Training 
& more. Info: 715-592-6595 • info@ 
the-mrea.org • www.the-mrea.org 

Amherst, Wl. Artha '08 workshops: Intro 
to Solar Water & Space Heating System, 

Installing a Solar Water Heating System, Living 
Sustainably & more. Info: 715-824-3463 • 
chamomile@arthaonline.com • 
www.arthaonline.com 

INTERNATIONAL 

GERMANY 

Jun. 10-11, '08. Munich. PV Industry Forum. 

Solar developments exhibition & forum. Info: 

Solar Promotion GmbH • 49-07231-58598-0 • 
www.pvindustry.de 

Jun. 12-14, '08. Munich. Intersolar 2008. Solar 
developments exhibition & forum. Info: 
www.intersolar.de 

NICARAGUA 

Jul. 21-31, '08. Totogalpa. Solar Cultural 
Course. Lectures, field experience & 
ecotourism. Info: Richard Komp • 207-497-2204 • 
sunwatt@juno.com • www.grupofenix.org 



Send your renewable 
energy event info to 
happs@homepower.com 




Adjustable Permanent Magnetic 
Brushless Alternator 



25 - 30% more efficient than Hi Output Alternator 
Marine Grade Construction throughout 
Re-connectable Stator 
Retrofittable on existing turbine 



Manufactured by Lo Power 
P.O. Box 1567 
Redway, CA 95560 



Hydro- Power for Home Use 



www.homepower.corn 



marketplace 



HYDROELECTRIC SYSTEMS: Pelton 
and Crossflow turbines or complete AC 
systems for standalone or grid interconnect 
operation. Site evaluation and equipment 
selection assistance. Manufacturing home 
and commercial size turbines since 1976. 
Free brochure: Canyon Industries, PO Box 
36HP, Deming, WA 98244, 360-592-5552. 
Email: info@canyonhydro.com Web page: 
canyonhydro.com • HP12502 



FOLLOW THE SUN! Light seeking single 
and dual axis solar tracker controls. 
www.theanalogguy.com • HP12503 



ECOMALL: The largest environmental 
portal of earth-friendly companies and 
resources. Renewable energy companies, 
news and information, www.ecomall.com. 
To advertise, call 845-679-2490. • HP12504 



XXXXXXX UNI-SOLAR XXXXXXXX 
XXXXXXX 64 Watts $359 XXXXXXX 
M55 Siemens panels $225. Almost new 
1500 AH AGM 12-volts $1800. TraceX 
SW5548 $2850. Ex 2KW inverter SB $850. 
Buy, sell New/Used. • 760-949-0505 • 
HP12505 



PORTABLE AND STANDBY GENERATORS 
from Honda, Yamaha, Subaru, Kipor, and 
More + Wireless Remote Start Available. 
www.hayesequipment.com • 
1-800-375-7767 • HP12506 



NEMO DC SUBMERSIBLE WELL PUMPS: 
$239 Postpaid. New! NEMOSOLAR 
15A12/24V CHARGE CONTROL W/LVD: $56 
Postpaid. Immediate Shipping Worldwide. 
WWW.NEMOPUMPS.COM 1-877-684-7979* 
HP12507 



I AM A SOLAR WHOLESALER looking 
for retailers to carry my solar electronic, 
educational & hobby goods. Phone # (916) 
486-4373. Please leave message. • HP12508 



DC POWERED CEILING FANS: 12 & 24 
volts: The Best in the World: RCH Fanworks • 
info@fanworks.com www.fanworks.com 
PH: 509-685-0535. • HP12509 



EDTA RESTORES SULFATED BATTERIES. 
EDTA tetra sodium salt, $1 6/lb. plus $6 
S&H for 1st lb. plus $2 S&H for each 
additional lb. Trailhead Supply, 325 E. 1165 
N., Orem, UT 84057, (801) 225 3931, email: 
trailheadsupply@webtv.net, info, at: 
www.webspawner.com/users/edta. • 
HP12510 



HYDROELECTRIC TURBINES: Custom sized 
runners 50W-500kW, 82-400mm diameter, 
stainless investment castings and 
molded plastic, from $120, site analysis 
spreadsheets, www.h-hydro.com • HP12511 



WANT TO LIVE RENT-FREE - anywhere 
in the world? There are empty homes in 
every state and country, and property 
owners are looking for trustworthy people 
to live in them as property caretakers 
and housesitters! The Caretaker Gazette 
contains these property caretaking/ 
housesitting openings in all 50 states 
and foreign countries. Published since 
1983, subscribers receive 1,000+ property 
caretaking opportunities each year, 
worldwide. Some of these caretaking 
and housesitting openings also offer 
compensation in addition to the free 
housing provided. Short, medium and 
long-term property caretaking assignments 
are in every issue. Subscriptions: $29.95/ 
year. The Caretaker Gazette, 3 Estancia 
Lane, Boerne, TX 78006. (830) 755-2300 • 
www.caretaker.org • HP12512 



HYDROS, P.M. BRUSHLESS DC units with 
Harris housing and wheel. Up to 70% 
efficiency. From $1350. 
www.homehydro.com 707-923-3507 CA • 
HP12513 




RENEWABLE 
ENERGY 



The biggest sustainability event in the South! 



Green Products for Sale 



Renewable Energy 
Green Building 
Water Use & Reuse 
Energy Efficiency 
Organic Growing 
Alternative Fuel Vehicles 



ROUNDUP 




& GREEN LIVING FAIR 
Sept. 26-28, 2008 ■ downtown Fredericksburg/TX 



Lectures ■ Exhibits 
Demonstrations ■ Family Activities 
Organic Food ■ Music 



877-3ROUNDUP ■ email:Roundup@txses.org - WWW.TheRoundup.org 



home power 125 /june & july 2008 




SOLAR THERMAL BUSINESS FOR SALE 
Well established, good income, growth 
potential, in a beautiful area in the Pacific 
Northwest. Will train the right person. 
Contact: solar4sale@gmail.com • 
HP12514 



RE-MANUFACTURED JACOBS WIND 
TURBINE 31-20kw model complete with 
tower and UL508 inverter $26,500 O.B.O. 
661-724-1488 Jason • HP12524 



CONTAIN YOUR BATTERIES SAFELY with 
vented HDPE box complete with welded 
seams and removable lid. Custom sizes 
available, UPS shippable. 
radiantsolartech.com 707-485-8359 • 
HP12515 



LED bulbs from CCrane at discount 
prices. Many styles available in 12V and 
120V. radiantsolartech.com 707-485-8359 • 
HP12516 



LARGE GAS REFRIGERATORS 12, 15 & 18 
cubic foot propane refrigerators. 15 cubic 
foot freezers 800-898-0552 Ervin's Cabinet 
Shop, 220 N County Rd. 425E., Areola, IL 
61910* HP12517 



OFFERING STOCK PASSIVE SOLAR HOME 
BLUEPRINTS for building a beautifully 
simple, cost effective, energy efficient 
home. Steve Kawell 970-769-3904 • 
www.durangosolarhomes.com • HP12518 



ANYTHING SOLAR POWERED: A handy 
website for information on energy-saving 
products, green living tips, letters, opinions 
and photos. 

www.AnythingSolarPowered.com • 
HP12519 



JACOBS: (4) 32 VDC, (3) 10KW MACHINES. 
MasterMinds battery charger or utility 
intertie. Manuals, tools, parts. Rohn SSV 
towers. 907-562-3832 • 
afehr@uaa.alaska.edu • HP12520 



GET HOT AIR OUT OF YOUR ATTIC! Solar- 
Powered Attic Fans 
www.southsideatticsolution.com 
(317) 847-4546 * HP12421 



BIODIESEL PROCESSORS - High quality, 
low price, 15 to 40 gallon capacity in one 
garage sized unit, technical support. Visit 
www.parmabiodiesel.com • HP12522 



TAB RIBBON.COM.- We offer tab and bus 
ribbon for building solar panels. Several 
sizes and compositions including: 62/36/2 
silver-bearing, 60/40 and others. Small and 
large quantities available. We stock solder 
of various types as well. Please visit our 
websites for the finest in U.S.A made flat 
wire, www.tabribbon.com • 
www.solar-underground.com • 
www.dbsolar.com • HP12523 



SOLAR POWERED RETREAT in 
beautiful Nelson County, VA., close 
to Charlottesville. $315,000.00. More 
information: www.greenhomesforsale. 
com, listing #18181 in Howardsville, VA • 
HP12525 



UNIQUE LAKEFRONT LIVING ON THE 
OREGON COAST! Off the grid community 
in a spectacular location on Booth Island 
in Siltcoos Lake. Choose from 2 custom 
homes and 4 large parcels. Virtual tour 
at www.boothisland.com. Call today 
541-999-2336 * HP12526 



FOR ALL YOUR OFF GRID NEEDS . 
Panels, Controllers, Inverters & Batteries. 
AERMOTOR water pumping windmills, 
new & vintage, parts & supplies. KOHLER 
LP 8.5, 12 & 17 kw generators. 
www.timeforsolar.com. (970)209-4764 • 
HP12527 



Marketplace Advertising 

Rates: $2.50 per word. $50 minimum per 
insertion, paid in advance of publication. 
Submit your ad to marketplace@ 
homepower.com or call 800-707-6585. 




Keynote Speaker: 

Greg Pahl 

Author of 

“The Citizen-powered 
Energy Handbook” 



2008 



Grant County Fairgrounds 

John Day, Oregon 



541 - 575-3633 

info@solwest.org 



www.solwest.or g 



Neighbors, 



RENEW/ABL 



3ft. 


m -iM- 




MW 


Tf&l 






EjWTHTC'T* 












www.homepower.corn 




installers directory 

Experienced renewable energy professionals install high-performance, code-compliant systems, and will 
offer you service and support after the sale. As with any home improvement project, request references 
and certifications, and compare bids before you buy To get your business listed in Home Power's 

installers directory, e-mail advertising@homepower.com or call 541-512-0201. 



Alabama 




Affordable Solar Hot Water and Power installs 
in Alabama and Georgia, solar hot water, pool heating, 
and electricity. We consult and certify for, energy efficiency, 
green building, new construction or existing buildings, for 
tax credits, to increase value, comfort and air quality The 
most reliable products, at a fair price, www.asolarpro.com, 
asolarpro@gmail.com phone 334-828-1024. 



Alaska 




ABS Alaskan, Inc. Anchorage - Fairbanks - Renton, 

WA Battery systems. Remote power systems, RE systems. 
OEM design and fabrication. Consultation & design, sales, 
installation, & service for solar, wind, hydro, and hybrid 
components and systems since 1989. Web - www.absAK.com. 
Toll free 800-235-0689 or 800-478-7145, email jim@absAK.com. 



Arizona 



C&R 
SOLA ft 



C & R Solar Quality design, sales and installations of 
solar/ wind power systems to meet your application. Serving 
northwest Arizona since 1989 for remote homes and grid 
tied systems. Living off grid since 1980. We achieve customer 
satisfaction with over 25 years of experience in renewable 
energy. ROC135882. 928-757-7059. 



California, cont. 

Carlson Solar, has been serving Southern CA since 
1988. We are a licensed, bonded, and insured solar-electric 
C A n L so hr installation company, specializing in both grid-tie and off-grid 
Sfl La h systems. We are NABCEP certified and take great pride in our 
excellent customer service. Saving the environment one house 
at a time. Call toll-free 1-877-927-0782 or visit us at 
www.carlsonsolar.com 



CcbaFt 



Cobalt Power Systems Inc. is a full-service, licensed 
installer of PV systems in the SF Bay Area. We offer free 
consultations, detailed proposals, professional system design 
by an electrical engineer, expert installations, and competitive 
pricing. We handle all the paperwork for the client, and we 
oversee all inspections. Please contact us at 650-938-9574 or 
www.cobaltpower.com. 




Electron Connection Licensed in CA and Oregon. 
NABCEP Certified installer. Serving northernmost California 
and southern Oregon. PV, wind, microhydro installs. 
800-945-7587 email: bob-o@electronconnection.com, 
www.electronconnection.com CA Lie. #613554 




EV Solar Products, Inc. Licensed solar professionals 
since 1991. We design and install solar electric and hot 
water systems for grid-tie and remote homes. Visit our retail 
showroom just north of Prescott at 2655 N US Hwy 89. Chino 
Valley, AZ 86323 ROC Licenses: 129793/118299. 928-636-2201. 



Empower Energy, Southern California. We design, 
sell, install, & service high quality residential & commercial 
|_ solar electric generation systems. Specializing in grid-tied 

enerqy ER and remote stand-alone systems. Make renewable energy a 
responsible and cost-effective part of your home or business. 
Free project estimate 800 494-2366 empowerenergy.net info@ 
empowerenergy.net. Licensed since 1995, #711993 



Generator Solar & Wind Power Systems Design, 
Sales, installation & maintenance. Off-grid & grid-tied, prime 
■G.SlW. power or back-up. Complete systems, hybrid systems, or sub 

*lrv;i likllUk' ' systems & components. We can do it. Covering all of Arizona 
& dedicated to helping all present & potential customers. 
License # ROC203166, 928-300-4067, altpwrsys@hotmail.com 



Independent Energy Systems, Serving the 
Santa Cruz /Monterey Bay Area. We specialize in design, 
installation and sales of residential/commercial PV systems. 
■-.' 1 ^ r p\‘ ■ ■ j f.- j Our mission is to provide our friends in the community an 
fkj i itIy i'v iti lh'i opportunity to become part of the future in renewable energy. 

We are based in Santa Cruz, we love what we do and it shows 
in our work! Ph: 831-477-0943 or visit www.iesolar.com 



IDC 

Solar 



IDC Solar Exclusive products like the Guy-wireless 
Towers, Modular Wiring Unit and Automatic Battery 
Watering System for code compliant, worry-free hybrid 
renewable energy systems. We install locally or nationally. 
Complete licensing for all residential and commercial devices. 
Skystream turbines & towers up to 50' now available. 

928 636-9864 or idcllc@northlink.com • www.idcsolar.com 



I I +. I 1 .! 

■ I llikll 



Arkansas 

Rocky Grove Sun Company has been serving NW 
Arkansas and the surrounding region since 1986. Design, 
installation and consultation with two NABCEP certified 
installers: Flint Richter and Jimis Damet with over 35 years 
combined experienced in PV stand alone & grid-tied, wind and 
hydro. Located in the heart of NW Arkansas Ozarks. Contact us 
at 479-665-2457 or info@rockygrove.com www.rockygrove.com 



California 



Acro 

ELECTRIC 



Acro Electric is a full service electrical contractor 
specializing in solar power. We provide turn-key solutions 
for PV, standby power, LED lighting, and more. Approved by 
the League of California Homeowners (www.homeowners. 
org) & Better Business Bureau (www.midcalbbb.org). Free site 
analysis & brochure. (866)711-ACRO • www.acroelectric.com 
Quality installations backed by 32 years electrical experience. 



Michael Symons Electric, C-10 licensed electrical 
contractor. NABCEP certified installer. We design, sell, install 
Symons & service both commercial & residential Photovoltaic systems 
■->1 - - since 1982. We specialize in grid-tie and stand alone off grid 

CIcCllIC systems including solar wells. We are located in East San 

Diego County serving Southern California and Baja California 
Norte. Ph: 619-468-3277 or E mail symonselectric@aol.com 





Offline Independent Energy Systems, Since 1983. 
An electrical contracting co., we specialize in utility intertie 


P^/TIn5^ 


(with state rebate & net metering) & off grid systems. Owned 
& operated by Don & Cynthia Loweburg in Central CA East 




of Fresno. Don Loweburg NABCEP Certified Installer. POB 
231, North Fork, CA. 93643, (CA lie# 661052) ph 559-877-7080, 
fx 559-877-2980, ofln@aol.com www.psnw.com/~ofln 




REVCO Solar Engineering, Inc. has been serving 
Orange County, LA County and The Inland Empire since 
1977. We specialize in Solar Pool Heating, DHW and Solar 
Electric PV systems. REVCO is actively involved with the 
League of California Homeowners, the American Solar 
Energy Society and CALSEIA. B/C-46 Lie# 387219. 
www.revcosolar.com 800.274.3638 



Apex, Apex Solar Specializing in residential off grid and 
remote commercial solar power. We provide system design, 
sales and turn key installation. For do-it-yourselfers, we 
can help with wiring diagrams and 10+ years of off grid 
experience. Licensed contractors in California call us toll free 
at 888 782-0706 or visit us at www.apxsolar.com 





Solar Wind Works specializes in consultation, sales, 
design, service, & installation of complete RE systems. 
US Distributor for Proven Wind Turbines. We supply 
all components. Grid-connected or grid-independent. 
Truckee, CA 530-582-4503, 877-682-4503, NABCEP 
Certified Installer. CA Contractor's Lie # 796322 chris@ 
solarwindworks.com, www.solarwindworks.com 



home power 125 /june & july 2008 





















installers directory 



Canada 




Energy Alternatives has been serving Canadians for 
over 20 years. A licensed electrical contractor (BC Lies # 

86683) with professional installers throughout Canada. Expert 
consultation & design services, turn-key installed systems 
or DIY packaged system kits. Extensive inventory for fast 
delivery. Visit www.EnergyAlternatives.ca, Call 
1-800-265-8898. Canadian dealer inquiries welcome. 




Natural Power Products is Ontario's leading supplier, 
retailer and installer for solar, wind, domestic hot water, and 
other renewable energy technologies. Complete design and 
turn-key packages for home, cottage, rural, businesses etc. All 
applicable codes are adhered to and inspected by ESA.Visit: 
www.npp.ca e-mail: info@npp.ca call: 519-504-1600 

Colorado 



Namaste Solar Electric Inc.,Smart. Simple. Sustainable. 
Namaste Solar brings clean, reliable, & affordable renewable 
energy to homes, businesses, & nonprofits in Denver /Boulder. 
A values-based, 100% employee owned company committed 
Ninmte Soiih * 0 maintaining the highest standards of environmental 
— p f*£ 1 1 1 r • stewardship, customer satisfaction, community philanthropy, & 
professional integrity. (303) 447-0300 • www.namastesolar.com 




Solar Solutions Ltd. provides photovoltaic, wind & 
hybrid power systems & components for stand alone systems, 
grid tied, RV's & remote water pumping. Committed to 
providing the highest quality service & customer satisfaction. 
A proud member of Colorado SEIA and a lifetime member of 
the Colorado RE Society and ASES. Xantrex Certified Dealer. 
888 44solar or 888-447-6527 www.solarsolutions.com 

Florida 

Allsolar Service Company Inc., Allsolar is a Florida 
based design-build solar contracting firm specializing in solar 
pool heating, solar water heating, and solar electric systems 
I > LSOLAH for residential, commercial and industrial applications. Free 
Estimates. Harnessing the sun's energy since 1974. 
www.allsolarflorida.com l-888-6solar-l CVC056657 Joshua 
Bessette 




ECS Solar Energy Systems (tel) 352-377-8866 
www.ECS-solar.com f tom@ECS-solar.com We service FL, the 
Caribbean and the Southeastern U.S. FL's first solar contractor 
since 1977. Solar pool heating, hot water, and electric systems 
-commercial & residential. Solar lie. # CVC056643 Florida 
state certified for "grid-connected" systems. Contact us now 
to receive a free solar informational booklet. 



Michael Fink Electrical Inc. licensed/insured/ 

RE SOLAR bonded.electrical contractor specializing in design, sales,and 
AND quality installation services for grid-tie PV systems and 
GENERATOR ^ ome standby generators, serving Lee and Collier counties in 
TOM southwest Florida. Dealer for Guardian generators, Aeesolar, 
•V.UI I Sunwize. visit www.resolarandgenerator.com 239-218-2280, 
239-282-5721, erl3012717 



Maine 



Benchmark Solar PV and solar thermal solutions from 
design through construction for residential and commercial 
buildings. NABCEP PV Installer's Certification; Master 
3 Electrician licensed in Maine, NH, and MA. Master Plumber/ 
^ H Heating license. Grid-tie, off-grid, hot water and space 

heating applications. We also serve the island communities. 
Call 1-800-9SOLAR1 (976-5271) www.benchmarksolar.net 



Maryland 

Standard Solar Inc., serving Montgomery and Frederick 
Counties, Maryland, Northern Virginia, and Washington, DC. 
^TAnDAfTO since 2004. Specializing in residential solar electric installations. 
^ A|j A ^ Visit our Website: www.standardsolar. 202 Perry Parkway 
#7, Gaithersburg, Maryland, 20877. Tel. 301-944-1200; email: 
metrodc@standardsolar.com 

Massachusetts 



Nexamp, Inc. is a turnkey, renewable energy integration 
and full spectrum energy solutions company serving 
rt.jvh.HH homeowners, businesses and governments in Massachusetts, 
nexjfimp Our offerings include site feasibility assessments, business 
modeling, system design, permitting, installation and 
maintenance services. Learn more about our Veteran operated 
company at 978-688-2700 or at Nexamp.com 

Michigan 




Backwards to the Future Ltd, installing, designing 
and supplying solar equipment since 1986. OEM supplier of 
evacuated tube heat pipe technology for DHW & hydronic 
heating. Systems building integration by joint venture with 
registered architect. State licensed residential builder & solar 
mechanical contractor. POB 409 Fennville MI 49408 
tel: 269-236-6179 email: info@BTFsolar.com www.BTFsolar.com 



SACKETT 

BRICK 

Fireplace 

Design 



Sackett Brick is the mid-west distributor for Tulikivi 
masonry heaters. We have 10 dealers /installers in 8 states: 
Indiana, Illinois, Iowa, Michigan, Minnesota, Missouri, Ohio & 
Wisconsin. Tulikivi masonry heaters are a clean and efficient 
way to provide heating, cooking and baking with very little 
wood. Visit www.sackettbrick.com or call 800-848-9440. 
DEALER INQUIRIES WELCOME 



Montana 



Oasis Montana Inc. designs and sells renewable energy 
power systems in North America and also offers efficient and 
LP gas appliances. Call to discuss your project. 877-627-4768 
or 4778. Web sites: www.oasismontana.com, www.grid-tie. 
com, www.PVsolarpumps.com, www.LPappliances.com, 
www.eco-fridge.com, E-mail:info@oasismontana.com 



Nevada 




Alternative Energy Solutions, Reno, Nevada. We 
design, sell, install and service PV, wind, off grid and grid tie 
RE systems, Nevada State Licensed and Bonded Contractor, 
NABCEP PV Certified Installer. Xantrex / Trace Authorized 
Service Center, Xantrex Certified Dealer, Outback Factory 
trained field service technicians and Certified Uni-Solar field 
laminate installer. 775-857-1157 toll free 1-866-491-SOLR 



SCI 




Solar-Fit is one of Florida's oldest active solar contractors. 
Established in 1975, International Sun Protection, Inc. (dba 
Solar-Fit), has helped over 8,000 families and businesses 
"Plug into the Sun". Call (386) 441-2299 for FREE information 
on solar electric, solar pool and solar hot water systems, and 
solar attic fans, or visit us on the web at www.solar-fit.com 
State Certified Solar Contractor #CVC56690. 

Idaho 




Creative Energies Eastern Idaho's premiere full-service 
RE company. Solar & wind power for remote cabins, homes & 
ranches, utility grid-tied solar & wind power, solar hot water 
& heating, solar water pumping & passive solar home design. 
We custom design a system that fits your needs & budget. 
Trace certified dealer. Phone/fax: 208-354-3001 toll free 
866-332-3410 info@cesolar.com • www.cesolar.com 



Kentucky 

Solar Energy Solutions offers full-service design, 
consultation, and installation for renewable energy projects 
in KY, OH, IN, and surrounding states. We install off grid 
fr Seh-Ewa Inh to on-grid — residential to industrial. Employees maintain 

NABCEP PV and Solar Thermal certifications. Fully licensed 
and insured. Visit www.solar-energy-solutions.com or call 
859-312-7456. 



Solar Wind Works specializes in consultation, sales, 
design, service, & installation of complete RE systems. 

US Distributor for Proven Wind Turbines. We supply all 
components. Grid-connected or grid-independent. Truckee, 
CA 530-582-4503, 877-682-4503, NABCEP Certified Installer. 
NV Contractor's Lie # 59288. 

chris@solarwindworks.com, www.solarwindworks.com 

New Mexico 

Positive Energy, Inc. High quality residential and 
commercial solar power systems. Grid-tied and off-grid 
systems. Licensed, bonded, and insured electrical contractor 
serving NM since 1997. Three owners are NABCEP Certified 
Installers and live on solar power. Company is carbon- 
neutral. References on Findsolar. 505-424-1112. 
info@positiveenergysolar.com www.positiveenergysolar.com 




Solar Ray SolarRay.com Complete Solar Electric Systems 
for off-grid, grid-tie, and grid-tie with battery backup. Turn 
key installations to DIY. Also offer Electric Vehicles. Licensed, 
bonded, & Insured Electrical contractor. 2 NABCEP certified 
installers on staff. Serving New Mexico and Colorado for over 
10 years, ray@solarray.com, (575) 737-9553, www.solarray.com 



www.homepower.corn 



131 























installers directory 



New York 




Solar & Wind FX Inc. NY's only Off-grid Design & 
Training Center, where a client can see the latest RE & Green 
building technologies. A family owned, full service company 
focusing on Western NY that provides site evaluation, design, 
installation & the all important, service after the sale. Member 
of NESEA & NYSEIA, SEI alumni & a NYSERDA installer. 
585-229-2083, solarandwindfx.com 



North Carolina 

Argand Energy Solutions is an experienced, full- 
service provider of solar PV, solar hot water, solar pool 
j heating, and wind system design and installation, serving 

t|W;P residential, commercial, and government customers in NC, 

SC, GA, southeast; licensed and insured, for more information 
visit www.argandenergy.com or call (704) 583-9295, 
info@argandenergy.com. 



South Carolina, cont. 

0 Suns tore Solar Full service solar systems integrator, 
serving Carolinas & Georgia for 30 years. Proud to serve 
the community by providing the highest quality product 
and excellent customer service. Provide all services needed 
from consultation/ design to installation on all types of Solar 
Systems. 3090 South Hwy 14, Greer, SC 29650 864-297-6776, 
www.sunstoresolar.com, info@sunstoresolar.com 

Utah 

Alternative Power Systems, Inc. is Southern Utah's 
premier Designer & Installer of renewable energy systems. We 
provide design, sales, installation & service of Solar Power, 
Solar Hot Water, Wind & Back-up Generators. We are the 
region's only NABCEP certified. We are insured & licensed 
in Utah #6259909-5501 And Nevada #0068796. Compare our 
prices, www.apssolar.com 435-586-9181 





Sundance Power Systems, Inc. Serving the Southeast 
since 1995 with high-performing residential & commercial 
renewable energy systems, including SHW & radiant floor 
heat, solar, wind, & micro-hydroelectric. Providing value with 
over 13 years, thousands of installations, & millions of kilowatt 
hours of experience to serve you! Phone: 828 645-2080 
info@sundancepower.com, www.sundancepower.com 



Ohio 

REpower SOLUTIONS: Northeast Ohio's renewable 
energy provider for home & business. Design & professional 
installation of solar PV & wind systems. Home energy ratings 
& small commercial energy audits. Erika Weliczko - NABCEP 
Certified Solar PV Installer, OH LIC #44844, Certified Home 
Energy Rater WEB: www.repowersolutions.com, EMAIL: 
power@repowersolutions.com PHONE: 216-402-4458 




Solar Unlimited Energy & Homes, Inc. Serving 
Southern Utah, Eastern NV and Northern AZ since 1998. 
Providing sales, service and installation of all your alternative 
energy needs, including PV, Wind, Net-Metering, Off-Grid, 
Batteries and Generators. We are also an Authorized Xantrex 
Service Center. Licensed & Insured. Call toll free 866-solar99 
or visit www.solarunlimited.net 



Vermont 



Independent Power LLC Serving Northern Vermont 
and New Hampshire with PV design, sales and installation. 
NABCEP certified owner David Palumbo has built over 300 
off-grid and grid tied systems since 1988. Outback Certified 
Dealer. 462 Solar Way Drive, Hyde Park, VT 05655 
www.independentpowerllc.com 1-802-888-7194 






Third Sun Solar & Wind Power, Ltd. Ohio's 

premier solar and wind power contractor. Complete design 
and installation of utility tied or off-grid systems for OH 
and surrounding states. Serving commercial and residential 
customers. NABCEP Certified PV Installer committed to 
excellent customer service & the highest quality systems. 
www.third-sun.com 740 597-3111. 



Oregon 




Cascade Sun Works, a leading renewable energy 
contractor in Central Oregon, offers innovative products and 
cost-effective engineered solutions suited to your energy 
needs. We provide Solar Thermal and PV installed systems, 
pre-packaged kits, service and engineering. Licensed and 
certified. Visit www.sun-works.com or contact us at (541) 
548-7887 CCB #151227 




Electron Connection Licensed in CA and Oregon. 
NABCEP Certified installer. Serving northernmost California 
and southern Oregon. PV, wind, microhydro installs. 
800-945-7587 email: bob-o@electronconnection.com, 
www.electronconnection.com OR CCB# 149724 



Vermont Solar Engineering has provided the 
finest in renewable energy throughout New York and New 
England, since 1991. We design, install, and support solar 
electric, wind electric, and solar hot water systems. 

— K. Herander, NABCEP™ certified installer. Xantrex Certified 
Dealer. NYSERDA eligible installer. Vermont Solar and Wind 
Partner, www.vermontsolar.com 1-800-286-1252 

Virginia 




Dunimis Technology Inc. Providing alternative 
energy systems since 1992. NABCEP certified solar 
technicians on staff. We specialize in the more demanding 
upscale off-grid residential & commercial installations. 
Installations completed in ID, TX, PA, NJ, NC, VA, and WV. 
PO. Box 10, Gum Spring, VA 23065, Phone 804-457-9566, 
jryago@netscape.com, www.pvforyou.com 



Washington 



P H H Cl V 



Seraphim Energy, Inc. Full service electrical contractor 
serving the Columbia River Watershed. We specialize in on 
and off grid wind, sun and water powered systems, meeting 
all your design, installation and procurement needs. Seraphim 
Energy: your power provider. WA#SERAPEC971MG/OR 
CCB#175837 • 1-800-265-6288 www.seraphimenergy.com, 
re@seraphimenergy.com 



A 

Mr. Sun Solar 



Mr. Sun Solar Since 1980, the Northwest's leading 
solar installer. Over 1,900 projects including solar hot water, 
solar pool heating, solar attic fans, and on- and off-grid PV 
systems. Dealer for Sol-Reliant(TM), The Solar Water Heating 
System Built to Last - OG-300 and Bright Way(TM) approved. 
Phone: (888) SOL-RELY (888-765-7359). www.MrSunSolar.com 
and wwwSolReliant.com. 



SolarWind Energy Systems, LLC PO. Box 1234, 
Okanogan, WA 98840 509-422-5309 www.solar-wind.us WA 
Cont. # SOLARES983RQ. Serving Eastern WA & Northern 
ID grid-tied & off-grid RE systems. Solar PV, wind, solar hot 
water, remote stock watering. Design, installation, service, 
maint. Solar Energy International (SEI) trained. Lie. & 
bonded. bclark@solar-wind.us or jmartin@solar-wind.us 



Trinity Electrical Contractors Corp. A full service 
licensed electrical contractor specializing in PV and Wind 
system design and installs. Serving all of Central Oregon. We 
are proud to be an Energy trust of Oregon Trade Ally. Call 
541-923-0556 or visit us at www.trinityelectric.org 

South Carolina 

Argand Energy Solutions is an experienced, full- 
service provider or solar PV, solar hot water, solar pool 
j heating, and wind system design and installation, serving 

residential, commercial, and government customers in NC, 

SC, GA, southeast; licensed and insured, for more information 
visit www.argandenergy.com or call (704) 583-9295, 
info@argandenergy.com. 




Western Washington Solar designs & installs solar 
Air fa electric, solar hot water, solar space heating & wind power 
systems for residential & commercial clients throughout 
9 Washington. Renewable energy will save you money, add 
value to your home or business, & reduce greenhouse gas 
mF emissions. 360-319-6273, www.westernwashingtonsolar.com, 
9.™ email: info@westernwashingtonsolar.com 



Wyoming 




Creative Energies Wyoming's premiere full-service RE 
company. Solar & wind power for remote cabins, homes & 
ranches, utility grid-tied solar & wind power, solar hot water 
& heating, solar water pumping & passive solar home design. 
We custom design a system that fits your needs & budget. 
Trace certified dealer. Phone/fax: 307-332-3410 toll free 
866-332-3410 info@cesolar.com • www.cesolar.com 



home power 125 /june & july 2008 























"E* r 



Your Choice... 

in Renewable Energy Education 



www.solarenergy.org 










r f 






\ 



m i I 

IPlUfi^TB 

Hands-on Workshops & Online Courses 

-PV Design & Installation 
-Advanced PV-Design Criteria & NEC 
-Grid-tied Photovoltaics 
'Women's PV Design & Installation 
-PV Lab Week 
-Building for the Future 
-R.E. for the Developing World 
-Solar & Radiant Heating 
-Strawbale Construction & Plasters 
-Natural Home Building 
-Solar Water Pumping 
-Solar Hot Water 
-Micro Hydro 
-Wind Power 



. & 



SEI Online 

-PV Design Online 

•Advanced PV Online 
Design Criteria & NEC 

•Building for the Future Online 
Sustainable Home Design 



y 




Solar Energy International 
PO Box 7 1 5 Carbondale, CO 8 1 623 



39845 Mathews Lane Paonia, CO 81428 
970-963-8855 *fax 970-963-8866 
sei@solarenergy.org 






Don't miss the premier 
energy education event 
in the nation! 



Featuring 



4^ Annual Clean Energy Car Show 
Green Home Pavilion Newin ' a8 

KtainahlpTahlpc Wewinoe 





advertisers index 



A&C Green Energy, www.acgreenenergy.com 109 

AAA Solar Supply, www.aaasolar.com 104 

Abraham Solar, www.abrahamsolar.com 122 

ABS Alaskan Inc., www.absak.com 26 

AEE Solar, www.aeesolar.com 5 

Affordable Solar Group, www.affordable-solar.com 24/25 

Alternative Energy Store, www.altenergystore.com 71 

Alternative Power & Machine, www.apmhydro.com Ill 

Apex Solar, www.apxsolar.com 125 

Apollo Solar, www.apollosolar.com 89 

Apricus Solar Co. Ltd., www.apricus.com 53 

APRS World LLC, www.winddatalogger.com 125 

ART TEC, www.arttec.net 117 

Artha Sustainable Living, www.arthaonline.com 117 

BackHome Magazine, www.backhomemagazine.com 81 

Backwoods Solar Electric Systems, www.backwoodssolar.com 89 

Blue Sky Energy Inc., www.blueskyenergyinc.com 91 

Bogart Engineering, www.bogartengineering.com 90 

Brand Electronics, www.brandelectronics.com 122 

Butler Sun Solutions, www.butlersunsolutions.com 110 

BZ Products, www.bzproducts.net 1 17, 124 

C Crane Co., www.ccrane.com 125 

Careers in Renewable Energy, www.pixyjackpress.com 113 

CMS Magnetics, www.acgreenenergy.com 109 

Conergy Inc., www.conergy.us 3 

DC Power Systems Inc., www.dcpower-systems.com 65 

Efficient Radiant Systems LLC, www.efficientradiant.com 117 

Electric Auto Association, www.eaaev.org 1 13 

Electro Automotive, www.electroauto.com 104 

Electron Connection, www.electronconnection.com 72 

Energy Conservation Services, www.ecs-solar.com 80 

Energy Systems 8t Design, www.microhydropower.com 1 19 

Energy Wise Solutions, www.energywisesolutions.net 122 

Exeltech, www.exeltech.com 105 

Fronius USA LLC, www.fronius-usa.com 10/11 

Fullriver Battery USA, www.fullriverdcbattery.com 27 

Gorilla Electric Vehicles, www.gorillavehicles.com 125 

Green World Biofuels, www.greenworldbiofuels.com 122 

GroSolar, www.grosolar.com IFC, 35 

Harris Hydro, 707-986-7771 127 

Home Power Inc., www.homepower.com 64 

Hydrocap Corp., 305-696-2504 110 

Hydroscreen Co. LLC, www.hydroscreen.com 125 

Innovative Solar Inc., www.scsolar.com 109 

Intersolar US, www.intersolar.us 73 

Jan Watercraft Products, www.janwp.com 125 

Kaco Solar Inc., www.kacosolar.com 44 

Liberty Enterprises Inc., www.iloveebikes.com 122 

Living With Nature Festival, www.livingwithnature.net 122 

Lorentz GMBH & Co. KG, www.lorentzpumps.com 15 

Magnum Energy, www.magnumenergy.com 17 

Midnite Solar Inc., www.midnitesolar.com 28 

Mitsubishi Electric, www.mitsubishielectricsolar.com 36 

MK Battery, www.mkbattery.com 79 

Morningstar Corp., www.morningstarcorp.com 79 

N. Am. Board of Cert. Energy Practitioners, www.nabcep.org 119, 123 

New Society Publishers, www.newsociety.com Ill 

Northern Arizona Wind & Sun, www.solar-electric.com 110 

Northwest Energy Storage, www.solaronebatteries.com 105 



Offline Independent Energy Systems, www.psnw.com/~ofln 114 

OutBack Power Systems, www.outbackpower.com 8/9 

Phocos USA, www.phocos.com 114 

RAE Storage Battery Co., 860-828-6007 124 

Renewable Energy and Sustainable Living Fair, www.the-mrea.org .... 134 

Rheem Water Heaters, www.solahart.com 37 

RightHand Engineering, www.righthandeng.com 124 

S-5!, www.s-5.com 1 19 

Samlex America Inc., www.samlexamerica.com/solar 103 

San Juan College, www.sanjuancollege.edu/reng 123 

Sanyo Energy USA Corp., www.us.sanyo.com BC 

Silicon Solar, www.siliconsolar.com 2 

Simmons Natural Bodycare, www.simmonsnaturals.com 124 

SMA America Inc., www.sma-america.com 23 

Solar Converters Inc., www.solarconverters.com 80 

Solar Depot Inc., www.solardepot.com 20/21 

Solar Energy International, www.solarenergy.org 133 

Solar Pathfinder, www.solarpathfinder.com 110 

SolarFest, www.solarfest.com 123 

Solargenix Energy LLC, www.solargenixchicago.com 119 

SolarH20t LTD, www.solarhotusa.com Ill 

SolarWorld California, www.solarworld-usa.com 29 

Solectria Renewables, www.solren.com 90 

Solmetric Corp., www.solmetric.com 103 

Sol-Reliant www.solreliant.com 91 

SolWest RE Fair, www.solwest.org 129 

Southwest Solar, www.southwest-solar.com 124 

Southwest Windpower, www.windenergy.com 13 

Staber Industries Inc., www.staber.com 118 

Steca GmbH, www.stecasolar.com 109 

Stiebel Eltron Inc., www.stiebel-eltron-usa.com 55 

Sun Frost, www.sunfrost.com 118 

Sun Pipe Co. Inc., www.sunpipe.com 115 

Sun Pumps Inc., www.sunpumps.com 81 

Sun Spot Solar, www.sssolar.com 118 

SunDanzer, www.sundanzer.com 103 

SunEarth, www.sunearthinc.com 114 

Suntech Power Holdings Co. Ltd, www.suntech-power.com 45 

SunWize, www.sunwize.com 19 

SunXtender, www.sunxtender.com 4 

Surrette Battery Company Ltd, www.rollsbattery.com IBC 

SustainableChoice.net, www.sustainablechoice.net 115 

Texas RE Roundup 8t Green Living Fair, www.theroundup.org 128 

The Carbon Free Home, www.chelseagreen.com 81 

Thermomax, www.solarthermal.com 126 

Trina Solar Ltd., www.trinasolar.com 63 

Trojan Battery Co., www.trojanbattery.com 54 

U.S. Battery, www.usbattery.com 102 

UniRac Inc., www.unirac.com 88 

Wattsun (Array Technologies Inc.), www.wattsun.com 115 

Western NC Renewable Energy Initiative, www.wind.appstate.edu ....115 

Wiley Electronics LLC., www.we-llc.com 118 

WindMax Energy, www.magnet4less.com 124 

Windstream Power LLC, www.windstreampower.com 124 

Xantrex, www.xantrex.com 1 

XC3 International LLC, www.xc3solar.com 114 

Zephyr Industries Inc., www.zephyrvent.com 124 

Zomeworks Corp., www.zomeworks.com 123 



For easy online access to advertisers, visit www.homepower.com/resources/advertisers 



www.homepower.corn 






People 



Who: Meg Thomas 
Where: Ashland, Oregon 
When: 2004 to present 

Why: Because it's never too late to do 
your part 



lE 



Meg Thomas is a grandmother — and at first glance, a 
pretty conventional one. She goes by "Mammie" or 
"Nanna," and wears her hair in silver curls — but don't 
be fooled by her typical appearance. This church-going 
grandmother of seven is a feisty, forward-thinking one. 

Other grandmothers might drive 
a late-model Cadillac or luxury 
Town Car. Not Meg. At 85, she 
cruises around in a Toyota Prius. 

"It's such a neat car. Not only do I 
feel 'with-it,'" she laughs, "driving 
a hybrid or electric vehicle is the 
right thing to do." 

Thomas is proud that her car 
stands out in town and even more 
pleased that she can drive up to 
54 miles on a gallon of gasoline. 

Her commitment to conservation 
doesn't end with her wheels, 
though. When she's not doting 
on her grandchildren or great 
grandchildren, playing bridge, or 
tending to her vegetable garden, 
she's counting the kilowatt-hours 
generated by the solar-electric 
system that she had installed on 
her home in 2004. 

Thomas got serious about 
renewable energy a few years 
ago — after downsizing to a modest, 
single-story home "to save her 
bones and save energy." She 
heard that the city offered a variety 
of services and incentives to help 

residents improve the efficiency of their homes. "It was easy, 
she says. "I just made a few calls, and before I knew it, I had 
guys in here using blowers and all sorts of gadgets to find all the 
air and energy leaks." 



A woman ahead of her time, Meg 
Thomas invested in PV, energy 
efficiency, and efficient transportation — 
for the sake of future generations. 

grandchildren at holidays and birthdays, 

I decided to give them the gift of solar 
energy and help make the world a better 
place for them." 

Like many people living on savings and 
social security, Meg stretches every dollar 
with coupons and senior-citizen discounts. 
When it came to investing in energy, she 
was equally thrifty — taking advantage 
of city, state, and federal incentives 
that covered more than half of the cost 
associated with the efficiency upgrades 
and PV system. 

Meg paid roughly $10,000 for the PV 
system, which generates about 3,300 
KWH of electricity annually. Any power in 
excess of her needs is sold back to the grid. During the summer, 
her meter spins backward, earning her roughly $7 per month. 
"Even in the darkest months of winter, I have the lowest electric 
bill of all my friends," she says. 



The energy audit showed that her 1975 home would require 
several upgrades to achieve optimal efficiency. Meg didn't 
hesitate. She hired professionals to replace the heating ducts, 
install double-pane windows, and amend the insulation. But 
she didn't stop there. Next came a new roof and a batteryless, 
grid-tied 3.3 KW solar-electric system — complete with 15 Sanyo 
photovoltaic (PV) modules that feed into a Fronius IG3000 inverter. 



Although Meg wasn't concerned if the system paid for itself in 
her lifetime, rebates and incentives add up for a quick payback — 
about 10 years. But for her, this wasn't the point. "Nothing that 
I've ever spent money on has paid me back, so why should that 
matter now? It's an investment in our planet," she says. "People 
always ask, 'Do you think the system will pay for itself?' I say, 'I 
don't care if it pays me back. It will pay the world back.'" 



"We waste so much and have too much," Thomas says. Robert Plain (bobplain@yahoo.com), 

"Instead of buying pointless gifts for my grandchildren or great with Kel| y Davidson (kelly.davidson@homepower.com) 



home power 



125 /June & july 2008 



Shawn Schreiner (2) 







b [j)qrj££) 



7 25274 78082 2 



OUR ULTIMATE GUIDE TO SOLAR WATER HEATING SYSTEMS 



j .'Mike arid'Joanne Young 

_ -trade their'Vermont heating 

!■ ■ m 

bills for sustainable'sailing in 
k " She Caribbean each winter. 



PUMP 

WATER 

with Sunshine 

Rainwater 

Harvesting 

HOW-TO 



Creating a 
Net Zero-Energy 
Home or Business 

Get Your Geek On: 
PV Array Sizing 

Microhydro 
Pipeline Design 





groSolar 




What 

the 

World 

Needs. 

NOW 



A Full Service Solar Distributor, 
groSolar Delivers... 

0 Largest product selection from warehouses 
across North America 

0 Business and technical training and field assistance 
0 Turnkey and custom solutions 
0 Solar energy industry advocacy 



Visit Us At the Next Show Nearest You... 




Midwest Renewable Energy Fair 


6/20 


Custer, Wl 


Sol West Fair 


7/25 


John Day, OR 


Solar Power 2008 


10/13 


San Diego, CA 


CanSIA Solar Conference 2008 


12/7 


Toronto, ON, CN 


Co to groSolar.com/events for more 


information 





Become a groSolar partner today 

Solar Electric O Solar Hot Water O Solar Air Heating 
8oo GO SOLAR (800.467.6527) groSolar.com 





OUR STANDARD LABEL 




Rolls has been producing premium batteries 

specifically designed for the renewable energy market since 1 984. 
That’s why those who can’t afford to go without power know they 
can’t afford to trust anyone else. 




BATTERY ENGINEERING 



Superior Cycling | Dual-Container Construction | Widest Range of Specs 
HH 1 Largest Liquid Reserves | Easiest to Install | Longest Life Span | Premium Warranties 

T. 1.800.681.9914 E. sales@rollsbattery.com www.rollsbattery.com 







Up VJSJ Wjm pa/ Ssiija/a 



Depends on system design, location & albedo 



HIT® Double 



SANYO'S new HIT® Double bifacial solar panel captu^WP 
both direct sunlight and reflected light from surrounding 
surfaces, generating electricity from both sides of the 
panel simultaneously. HIT Double can increase the 
amount of electricity produced by up to 30% * compared to 
single-sided HIT panels. With high kWh performance, HIT 
Double is the perfect choice to maximize rebates for 
projects that receive performance based incentives. Enjoy 
new possibilities with HIT Double including carports, BIPV, 
awnings, fences, trellises, walkways, canopies, deck 
coverings and more. 



SANYO Energy (USA) Corporation 



http://us.sanyo.com solar@sec.sanyo.com